MECH 373 Instrumentation and Measurements

Slides:



Advertisements
Similar presentations
Lecture 30 Review: First order highpass and lowpass filters Cutoff frequency Checking frequency response results Time-to-frequency domain relations for.
Advertisements

Lecture 4: Signal Conditioning
Experiment 17 A Differentiator Circuit
Electronic Devices Ninth Edition Floyd Chapter 10.
CHAPTER 3 Measurement Systems with Electrical Signals
1 Electrical Engineering BA (B), Analog Electronics, Lecture 2 ET065G 6 Credits ET064G 7.5 Credits Muhammad Amir Yousaf.
Operational Amplifier
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 8.1 Operational Amplifiers  Introduction  An Ideal Operational Amplifier.
 The output from a single amplifier is generally insufficient to drive an output device. In other words, the gain of a single amplifier is inadequate.
Frequency Characteristics of AC Circuits
A Differentiator Circuit.  All of the diagrams use a uA741 op amp. ◦ You are to construct your circuits using an LM 356 op amp.  There is a statement.
Experiment 17 A Differentiator Circuit
Filters and the Bode Plot
Chapter 8 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Kent Bertilsson Muhammad Amir Yousaf. DC and AC Circuit analysis  Circuit analysis is the process of finding the voltages across, and the currents through,
1 Passive components and circuits - CCP Lecture 4.
© 2012 Pearson Education. Upper Saddle River, NJ, All rights reserved. Electronic Devices, 9th edition Thomas L. Floyd Electronic Devices Ninth.
Chapter 10 Analog Systems
ELECTRONIC INSTRUMENTATION & PLC DKT Signal Conditioning Circuits.
Lecture 2: Measurement and Instrumentation. Time vs. Frequency Domain Different ways of looking at a problem –Interchangeable: no information is lost.
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
Electronics Technology Fundamentals Chapter 15 Frequency Response and Passive Filters.
AUDIO OSCILLATORS An audio oscillator is useful for testing equipment that operates in the audio-frequency range. Such instruments always produce a sine-wave.
Measurement and Instrumentation
The Working Theory of an RC Coupled Amplifier in Electronics.
MECH 373 Instrumentation and Measurements
MECH 373 Instrumentation and Measurement
Chapter 10: Operational Amplifiers
MECH 373 Instrumentation and Measurements
(3) Signal Conditioning
(4) Filters.
Frequency response I As the frequency of the processed signals increases, the effects of parasitic capacitance in (BJT/MOS) transistors start to manifest.
Electronic Devices & Circuits
Operational Amplifier
Signal Generators Term 8.
MECH 373 Instrumentation and Measurements
ELG4135: Electronics III (Fall 2005)
MECH 373 Instrumentation and Measurements
Analogue Electronics Circuit II EKT 214/4
Analogue Electronic 2 EMT 212
Electronic Devices Ninth Edition Floyd Chapter 12.
MECH 373 Instrumentation and Measurements
Medical electronics II
Applications of operational Amplifiers
Harmonic Distortion Analyzer, Wave Analyzer and Function Generator
Filters and the Bode Plot
Operational Amplifiers (Op Amps) in Chemical Instrumentation
TOPIC 3: FREQUENCY SELECTIVE CIRCUITS
OP-AMPS: basics & Inverting-amplifier
Chapter 5: BJT AC Analysis
Feedback Amplifiers.
POWER AMPLIFIERS.
Chapter 1 Introduction to Electronics
Chapter 6 Feedback Circuits
Fundamentals of Electric Circuits Chapter 14
Amplifiers Classes Electronics-II
Chapter 11 Amplifiers: Specifications and External Characteristics
Content Op-amp Application Introduction Inverting Amplifier
Amplifiers Classes Electronics-II
Chapter 4 – Operational Amplifiers – Part 2
Chapter 3 ACTIVE FILTER.
Medical electronics II
8.4 Advanced RC Filters high pass filter including gain and Bode plots
Chapter 4 – Operational Amplifiers – Part 1
C H A P T E R 17 A.C. Filter Networks.
MECH 373 Instrumentation and Measurements
Chapter 5: Active Filters
CHAPTER 59 TRANSISTOR EQUIVALENT CIRCUITS AND MODELS
Frequency response I As the frequency of the processed signals increases, the effects of parasitic capacitance in (BJT/MOS) transistors start to manifest.
Chapter 10 Analog Systems
Presentation transcript:

MECH 373 Instrumentation and Measurements Lecture 4 (Course Website: Access from your “My Concordia” portal) Measurement Systems with Electrical Signals (Chapter 3) • Electrical signal measurement systems • Signal conditioners Amplification Attenuation Filtering

Components of Measurement Systems

Electrical Signal Measurement Systems • Measuring systems that use electrical signals to transmit information between components have substantial advantages over completely mechanical systems. • Almost all modern engineering measurements can be made using sensing devices that have an electrical output. • In such devices, the measurand causes a change in an electrical property of the device (e.g. resistance, capacitance or voltage), either directly or indirectly. • Electrical output sensing devices have several significant advantages over mechanical devices: 1. Ease of transmitting the signal from measurement point to the data collection point 2. Ease of amplifying, filtering, or otherwise modifying the signal 3. Ease of recording the signal • However, completely mechanical devices are sometimes still the most appropriate measuring systems.

Signal Conditioning There are many possible functions in the signal-conditioning stage. Some of the common functions are: Amplification Attenuation Filtering Differentiation Integration Linearization Combining a measured signal with a reference signal Converting a resistance to a voltage signal Converting a current signal to a voltage Converting a voltage signal to a current signal Converting a frequency signal to a voltage signal

Why Need Signal Conditioning? Large amplification for small signals Good transient response (i.e. small time constants) These are difficult to do with purely mechanical elements - due to friction and inertia!

General Characteristics of Signal Amplification • Signals in the millivolt range are common, and in some cases, signals are in microvolt range. • It is difficult to transmit such signals over wires of great length, and many processing systems require input voltage on the order of 1 to 10 V. • The amplification of such signals can be increased using a device called an amplifier. • The low-voltage signal, Vi, is amplified to a higher voltage, Vo. • The degree of amplification is specified by a parameter called the gain, G.

General Characteristics of Signal Amplification • Common instrumentation amplifiers usually have values of gain in the range 1 to 1000; however, higher gains can readily be achieved. • The term gain is often used even for devices that attenuate a voltage (i.e. Vo < Vi). • Hence, values of gain can be less than unity. • Gain is more commonly stated using a logarithmic scale, and the result is expressed in decibels (dB). For voltage gain, it is expressed as: • For example, an amplifier with a gain (G) of 10 would have a decibel gain (GdB) of 20 dB, and an amplifier with a gain of 1000 would have a decibel gain of 60 dB. • If a signal is attenuated, that is, Vo is less than Vi, the decibel gain will have a negative value.

General Characteristics of Signal Amplification • Although increase in signal amplitude is the primary purpose of an amplifier, an amplifier can affect the signal. For example, frequency distortion, phase distortion, etc. • Typically a signal contains a range of frequencies. However, most amplifiers do not have the same value of gain for all frequencies. • For example, an amplifier might have a gain of 20 dB at 10 kHz and a gain of only 5 dB at 100 kHz. • Frequency response of a typical amplifier is shown in the following figure. In the figure, the decibel (dB) gain is plotted versus the logarithm of the frequency. (Filter , 6dB per octave – next lecture)

General Characteristics of Signal Amplification • Typically, the gain has a relatively constant value over a wide range of frequencies. • However, at extreme frequencies, the gain is reduced (attenuated). • The range of frequencies over which the gain is almost constant is called the bandwidth. • The upper and lower frequencies defining the bandwidth are called corner or cutoff frequencies. The cutoff frequencies are defined as frequencies where the gain is reduced by 3 dB. - Filter An amplifier with a narrow bandwidth changes the shape of an input time-varying signal by an effect known as the frequency distortion.

General Characteristics of Signal Amplification •Gain of an amplifier is relatively constant over the bandwidth, another characteristic of the output signal called the phase angle may change significantly. • If the voltage input signal to the amplifier is in the form of a sine wave and expressed as Vi(t)= Vmi sin (2πft) where, f is the frequency and Vmi is the amplitude of the input sine wave. • The output signal will be Vo(t) = GVmi( 2πft +φ ) where, φ is called the phase angle.

General Characteristics of Signal Amplification • Figures of amplitude response and phase response together called Bode diagram or Bode plot. • Pure sinusoidal waveforms, the phase shift is usually not a problem. Complicated periodic waveforms, it may result in a problem called phase distortion. • Phase angle varies linearly with frequency, waveform shape will not be distorted and it will only be delayed or advanced in time. • Phase angle varies nonlinearly with frequency, the shape of the waveform gets distorted.

General Characteristics of Signal Amplification

Input Loading and Output Loading • Input loading and output loading are potential problems. Occur when using an amplifier. Using many other signal-conditioning devices. • Input voltage to an amplifier generated: Input or source device such as a sensor or another signal conditioning device.

Input Loading and Output Loading • Output voltage of the source device is altered: When it is connected to the amplifier - a loading problem. • Amplifier output has similar problem, when it is connected to another device, i.e. the amplifier output voltage is changed.

Input Loading and Output Loading • Consider a source and an amplifier separately without being connected Rs = Sensor R Ri = Amplifier input R. Ro = Amplifier output R. • Now consider the combined system where the input source, amplifier and the output load are connected together

Input Loading and Output Loading • Source not connected to amplifier: Voltage at the source output terminals will be Vs. No current flowing through Rs. Hence no voltage drop across Rs. • Source connected to amplifier: Voltage at source output terminals will no longer be Vs. Figure 3.9, Vs, Rs and Ri form a complete circuit. Current flowing through Rs. Resulting voltage drop across Rs. Amplifier has placed a load on the source device.

Input Loading and Output Loading • Similar behavior is observed when the output of the amplifier is connected to a device. • To minimize the loading effects at the input and output: Ideal amplifier (or other signal conditioner) should have a very high value of input resistance (Ri). Very low value of the output resistance (Ro). This can be seen from next slide.

Input Loading and Output Loading • To analyze this circuit, we will first solve the amplifier input voltage in terms of the source voltage . The current through the input loop is and hence, is given by: • Similarly, the voltage of the output loop, is given by: • Substituting first equation into the second equation, we get • If , the above equation will be approximated as • This is the equation of an ideal amplifier, that is, no loading effects.