Vacuum photodetectors: present and future

Slides:



Advertisements
Similar presentations
Vacuum Phototriodes for the CMS Electromagnetic Calorimeter Endcap
Advertisements

CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 1 Test results from 500 preproduction VPTs R M Brown RAL - UK CERN 19 September 2001.
STFC RAL EE at SLHC CERN 15/04/08 R M Brown - RAL 1 EE at SLHC What do we expect at SLHC? EE Layout VPT vulnerability to radiation - Faceplate darkening.
HEP Experiments Detectors and their Technologies Sascha Marc Schmeling CERN.
Particle interactions and detectors
Photomultipliers. Measuring Light Radiant Measurement Flux (W) Energy (J) Irradiance (W/m 2 ) Emittance (W/m 2 ) Intensity (W/sr) Radiance (W/sr m 2 )
Time-of-Flight at CDF Matthew Jones August 19, 2004.
Page 1 © J. Paul Robinson, Purdue University BMS 602/631 - LECTURE 8 Flow Cytometry: Theory Purdue University Office: Fax
New Calorimeter Technologies for NLC (a) Secondary Emission Calorimeter Sensors (b) Cerenkov Compensated Precision Calorimetry Y.Onel, University of Iowa.
Transducers Converts one type of energy into another. Light  Electrical (current, voltage, etc.) What characteristics should we look for in a transducer?
Page 1 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT BMS 602/631 - LECTURE 8 Flow Cytometry: Theory J. Paul Robinson Professor.
Photomultiplier Tube. What is it? Extremely sensitive detector of light in the ultraviolet, visible and near infrared Multiplies the signal produced by.
Liquid Helium Scintillation T. Wijnands EN/HDO Candidate for detecting beam losses in the LHC ?
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
Wide Bandgap Semiconductor Detectors for Harsh Radiation Environments
B W Kennedy, CCLRC Rutherford Appleton Laboratory VPTs for the CMS experiment B W Kennedy CCLRC Rutherford Appleton Laboratory St Petersburg, 26 April.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
Photon detection Visible or near-visible wavelengths
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze: Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS Detection.
PPARC forum on developments in scintillator technology R M Brown - RAL 1 Scintillating Crystals for Particle Physics Outline  Performance considerations.
CMS Week, CERN, 2002 R M Brown - RAL 1 Performance Characteristics of Production VPTs R M Brown, B W Kennedy, P R Hobson (with crucial input from D J A.
1 Components of Optical Instruments Lecture Silicon Diode Transducers A semiconductor material like silicon can be doped by an element of group.
SCINTILLATION COUNTER. PRINCIPLE When light radiations strike fluorescent material it produces flashes of light called scintillations. These are detected.
PSD8 September 2008, Glasgow.P R Hobson, Brunel University 1 Avalanche Photodiodes and Vacuum Phototriodes for the Electromagnetic Calorimeter of the CMS.
ELECTROMAGNETIC CALORIMETER at CMS EVANGELOS XAXIRIS June 2005 Experimental Physics Techniques.
CMS Hadronic Endcap Calorimeter Upgrade Studies
CMS SLHC workshop, D.J.A. Cockerill (RAL)1 CMS SLHC Workshop The CMS ECAL Detector at SLHC D Cockerill RAL
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
The CMS Electromagnetic Calorimeter Roger Rusack The University of Minnesota On behalf of the CMS ECAL collaboration.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
B W Kennedy, CCLRC Rutherford Appleton Laboratory Vacuum Phototriodes for the CMS Electromagnetic Calorimeter Endcaps K.W.Bell, R.M.Brown, D.J.A.Cockerill,
DETECTOR TECHNOLOGIES
LHCb HCAL PMT problems initial report 1 Yu. Guz. LHCb HCAL & ECAL 2 Yu. Guz PMTs of type HAMAMATSU R are used in both HCAL and ECAL. The detector.
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
RESMDD02 July , Florence, A.Singovski, University of Minnesota1 Radiation hardness of the Avalanche Photodiodes for ECAL CMS detector at CERN.
1 P.Rebecchi (CERN) “Monitoring of radiation damage of PbWO 4 crystals under strong Cs 137  irradiation in GIF-ECAL” “Advanced Technology and Particle.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
Ideas for Super LHC tracking upgrades 3/11/04 Marc Weber We have been thinking and meeting to discuss SLHC tracking R&D for a while… Agenda  Introduction:
SLHC Working Group - Nadia Pastrone1 CMS ECAL Detector at SLHC SLHC high radiation environment  consequences on ECAL Bunch crossing period:
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
CMS ELECTROMAGNETIC CALORIMETER Jean-Pierre Ernenwein OVERVIEW 6th international conference on advanced technology and particle physics Villa Olmo, Como,
HEP2001, Budapest, July 2001 R M Brown - RAL 1 The Vacuum Phototriodes for the CMS Electromagnetic Calorimeter P R Hobson, D C Imrie, O Sharif Brunel University,
Ilhan TAPAN* and Fatma KOCAK
Simulation of the Time Response of a VPT
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Scintillation Detectors in High Energy Physics
IOP HEPP Conference Upgrading the CMS Tracker for SLHC Mark Pesaresi Imperial College, London.
Frontier Detectors for Frontier Physics
HEP2001, Budapest, July R M Brown - RAL
Overview Detector details Crystals Photo-detectors
Radiation Damage Studies for Solid State Sensors Subject to Mrad Doses
Chapter 3. Components of Optical Instruments
PAN-2013: Radiation detectors
Proof of feasibility of VSiPMT (Vacuum Silicon PhotoMultiplier Tube)
Studies of the effect of the LHC cycle on
Particle Identification in LHCb
A study on stochastic term of calorimetric energy resolution
Studies of the effect of the LHC cycle on
CMS ECAL Endcaps: Fluence/Dose (500 fb-1)
Scintillation Counter
C.Octavio Domínguez, Humberto Maury Cuna
Semiconductor Detectors
Photomultiplier (PMT) Tubes
SoLID EC photonsensor.
Shukui Zhang, Matt Poelker, Marcy Stutzman
Development of microchannel plate phototubes in Novosibirsk
ELECTROMAGNETIC CALORIMETER
Presentation transcript:

Vacuum photodetectors: present and future What do we expect at SLHC? VPT properties Anticipated losses in VPT performance at LHC - Photocathode fatigue - Faceplate darkening Possible future approaches A word of caution Summary EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 1

What do we expect at SLHC? ∫L ~ 440 fb-1 LHC SLHC ∫L ~ 3040 fb-1 Total ∫ L ~ 3500 fb-1 (107 s/year, 50% efficiency) (cf ECAL TDR: ∫L ~ 500 fb-1)  ~ x7 Koutchouk IoP Liverpool Jun 2007 Instantaneous luminosity (cm-2s-1) Year EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 2

Dose versus  in EE (LHC) EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 3

Neutron fluence (>100keV) in EE EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 4

Fluence and Dose for 500 fb-1  Immediately behind crystals 500 fb-1 500 fb-1 Neutron + charged hadron fluence (cm-2) for E>100 keV 500 fb-1 Absorbed dose (Gy) EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 5

CMS Vacuum phototriodes Type PMT188 National Research Institute Electron, St Petersburg Vacuum Phototriode (VPT): Single stage photomultiplier tube with fine mesh grid anode Favourable B-field orientation in EE (VPT Axis: 8.5o < || < 25.5o wrt to B ) Active area of ~ 280 mm2/crystal ‘ Bialkali’ (CsK2Sb) photocathode + dynode coating Gain 8 -10 at B = 4 T Q.E. ~ 20% at 420 nm  = 26.5 mm MESH ANODE EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 6

Gain in a strong magnetic field B-field immunity requires a very fine anode mesh  Anode pitch =10 mm Primary electrons should pass through the anode and strike the dynode, but secondary electrons should be captured by the anode  Anode transparency = 50% 0 0.5 1.0 1.5 2.0 Magnetic field (Tesla) 600 500 400 300 200 100 Anode response (arbitrary units) Gain ~ 10 achieved with: - High bias voltages: V(A)/V(D) ~ 1000/800 - CsK2Sb coating on dynode  secondary emission coefficient ~20 Tilt angle =15O EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 7

Response vs tilt angle Angle scan at 1.8 T (RAL) p =10 mm Schematic of anode grid p =10 mm (a2/p2) = 0.5 Angle scan at 1.8 T (RAL) Effect of tilt on anode transparency EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 8

Phototube ageing h  ~ 650 fb-1 at h = 2.9  ~ 2000 fb-1 at h = 2.5 ~ 10 years ago, ageing tests were made at RAL and at Brunel on 1 inch VPTs from several manufacturers, at B=0 and B=1.8T. Most tubes showed similar behaviour. These plots are for RIE tubes. IK(0) = 200 nA B = 0 The fall in anode response is dominated by degradation of the photocathode The gain remains ~ constant VPT Photo-currents at LHC h Photocurrent (nA) L =1034 cm-2s-1 2.9 8.0 2.5 2.0 0.6 1.6 0.1 IK(0) = 200 nA B = 0 B = 1.8 T 30 days at IK(0) = 200 nA  ~ 650 fb-1 at h = 2.9  ~ 2000 fb-1 at h = 2.5 EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 9

Causes of photocathode degradation Positive ion bombardment Cs desorption Oxidation due to faulty metal in glass seals Electrolysis of the glass of the window Other Photocathode lifetime is often expressed as the ‘charge lifetime’, in Coulombs/cm2 Not a problem with well-constructed tubes Bias with cathode at 0V (a/c couple anode) Measurements on an RIE tube show a behaviour that is well described by the sum of two exponential terms – indicating two distinct effects. These are sometimes termed ‘conditioning’ and ‘ageing’. Assuming linear scaling to a typical EE/LHC photocurrent of 2 nA: C1 ~0.25 and t1 ~ 65 days C2 ~0.75 and t2 ~ 3x104 days t1 is consistent with a simple estimate of the time to sweep up the residual gas in the tube (positive ion bombardment) It is tempting to attribute t2 to Cs desorption I0(K) = 200 nA B = 0 R=R0 {0.225 exp(-t/0.65) + 0.775 exp(-t/280)} EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 10

Positive ion bombardment Photocathode damage caused by positive ion bombardment increases with ion energy.  Pre-condition by operating the tubes at low bias for ~100d at Ik = 2nA ?? (tests are planned but note importance of gain) (Note: in principle one could precondition the tubes as diodes with V(K) = V(A) =0 and V(D) = -200V, using the dynode as the photocathode. In this configuration all the ions would be swept on to the dynode, which appears to be less sensitive to damage. However, without internal gain, this would take a prohibitively long time at practical levels of illumination.) Note also that positive ion damage self-anneals to some extent when a tube is ‘rested’ for several months – so a pre-conditioning strategy would need repeating. Not to scale!!! The secondary emission coefficient of the dynode ~20.  Positive ion production is dominated by secondary electrons - both in the anode-dynode gap and the anode-cathode gap Ions strike the cathode with <E(I+)> = 900 eV Ions strike the dynode with <E(I+)> = 100 eV EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 11

Radiation-darkening of faceplates (n & g ) l (nm) Induced absorption  Light loss (PWO) ~ 9% Induced absorption vs l for US-49C faceplate (1mm) exposed to 20kGy g (60Co) ( = 2.6 at LHC) PWO emission properties Neutron fluence is 7x1014 n/cm2 (Reactor) Accompanying g-dose ~100 kGy Relative loss, weighted by emission, = 23.5% For comparison, expected exposures at LHC (500 pb-1) at  = 3 are: 7x1014 n/cm2 and 50 kGy (Super radiation hard vacuum phototriodes for the CMS endcap ECAL, NIM A535, 2004, 511-516 Yu.I.Gusev, et al.) EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 12

‘Ruggedizing’ vacuum photodetectors (1) Window transparency: Fused silica (‘quartz’) is extremely radiation hard, but requires ‘graded seals’  increased cost, increased length, increased vulnerability to He ingress. However, UV-transmitting and Ce-doped glasses with improved radiation resistance are now available US-49A faceplate exposed to 1016 n/cm2 together with a g dose of 1600  250 kGy [Yu.I. Gusev et al., NIM A 581, 438, (2007)] Unfolding neutron damage using extrapolated 60Co data (and ignoring gs from induced activity in the glass):  DT/T0 (neutron) < 15% for EE  < 3.0 at SLHC Neutron fluence 7x1014 n/cm2 Accompanying g-dose ~100 kGy Yu.I.Gusev et al. VCI Conf, Vienna, 2004 P.R.Hobson et al., Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications, Como, 2003 EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 13

‘Ruggedizing’ vacuum photodetectors (2) Positive ion damage (‘conditioning’): Improve the vacuum: for example, incorporate a getter – tests on a single device during R&D for CMS showed a marked improvement. Operate at low bias voltage - incompatible with large internal gain  use vacuum photodiodes? Caesium desorption: Popular high efficiency photocathodes for visible light almost all incorporate Cs. However, alternatives are available: E.g. ‘High temperature bi-alkali’ (Na2KSb) (used in oil-well logging) - Q.E. ~16% at 400 nm. EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 14

EE replacement/upgrade?? PbWO4  LYSO ? lemiss ~ (380-460) nm, LY(LYSO) ~ 200 x LY(PWO) What photo-detector? Silicon devices: Neutron damage  high leakage currents  amplifier noise? ‘Nuclear counter effect’ (for a simple photodiode, direct sensitivity to shower leakage particles >> sensitivity to scintillation light  high energy tail on energy measurement) APD? Vacuum devices: - Good match to biakali photocathode - Internal gain not necessary  Vacuum photodiode? EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 15

EE Activation Occupational dose limit: 20 mSv/yr 100 200 300 400 z(cm) 150 50 r(cm) Estimated dose rate in mSv/h after 60 d at L = 5x1033cm-2s-1 and 1 d cooling. (CMS closed) After 4 months cooiling the dose rates are ~2.5x lower 54 24 LHC (ECAL TDR) Occupational dose limit: 20 mSv/yr (Note: this is the legal limit, the normal CERN limit is 6 mSv/yr – except for the (very few) ‘Class A’ workers) Assume induced activity levels at SLHC ~10xLHC  Time to Annual limit at h = 3 is ~12 h EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 16

Layout of EE elements EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 17

Partial endcap upgrade for SLHC? At VPTs: Dose(h =2.2)/Dose(h =3.0) ~1/10 (neutron fluence ~1/3) ~25% (18/71) Supercrystals are at h >2.2 Only replace detectors at small radius ? Very challenging because of complexity of EE construction and high radiation levels  Needs detailed study h EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 18

Summary EE photodetectors at small radius will be significantly degraded after 500 fb-1 (Anode response  ~ 50% at h = 3.0) Development of ‘ruggedized’ vacuum photo-detectors appears feasible (Interest from Brunel, RAL, UVa……) A partial replacement of EE would be challenging EE Photodetectors for SLHC FNAL 20/1108 R M Brown - RAL 19