Gas Analysis for the Recreational and Technical Diver

Slides:



Advertisements
Similar presentations
Chapter 2 Scuba Diving Tanks / Air Cylinders Valves
Advertisements

Compressed Gas Cylinder Safety
NITROX PRODUCTION WITHIN A DIVE OPERATION
Mass Flow Controller. Function Delivers user specified flow rate of gas. Flow rate is mass flow rate (i.e. number of molecules per sec Mol/sec), not volume.
Operating Nitrox Systems 11 Presented by Nuvair. Operating Nitrox Systems2 Membrane systems produce nitrox efficiently Compressed air flows through the.
Chemistry An Introduction to General, Organic, and Biological Chemistry, Eleventh Edition Copyright © 2012 by Pearson Education, Inc. Chapter 6 Gases 6.8.
Permanent Head Gasket & Block Repair w/Nanotechnology, 32 Fl Oz
1 Chapter 6 Gases 6.8 Partial Pressures (Dalton’s Law) Copyright © 2009 by Pearson Education, Inc.
1 HYDROSTATIC TESTING Approved for Public Release.
Control System Instrumentation
A VISUAL AID TO PYROMETRY COMPLIANCE (A Guide To An Acceptable TUS Report) February 2010.
What we do and why we do it. Know how to inspect an SCBA bottle for damage prior to fill Know how to use the compressor Know how to document problems.
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
OXYTRONIC 600 CONTINOUS FLOW NITROX SYSTEM
Selection of measuring instruments
1 Chapter 6 The States of Matter 6.9 Partial Pressure (Dalton’s Law)
Calibration (Qualification) of Centrifuge
Classification of Instruments :
AccuMax Multi-Point Injection Mechanics
MSU Extension Pesticide Education Turfgrass Pest Management (Category 3A) Application Calculations and Calibration Chapter 5.
Unit 11: Calibrating Instruments
NFPA 31 Standard for the installation of Oil- Burning Equipment
The Problem The Problem
BSAC Ocean Diver Training
Calibration Savvy. Calibration and Conformance  Calibration: Check a measurement against a known universally recognized standard to determine any deviation.
The complete flow monitoring solution Measure – Display – Switch – Transmit.
Student Notes.
1 A/C Pressure Test and Evacuation. 2 Leak Detection Leak detection must be done after every repair job. It must also be done anytime the appliance can.
Partial Pressure (Dalton’s Law)
Testing Considerations Because of potential life threatening consequences resulting from device malfunction, it is critical that the device be fully tested.
Handheld Digital Manometers The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Unit 1 - Introduction Student Performance: By the end of the lesson you will be able to: Describe what nitrox is. List other names for nitrox. State the.
© SSER Ltd. How Science Works Selecting & Using Apparatus.
Unit 1: What is NITROX? Is it better than air? Do you need it?
SAL COLLEGE OF ENGINEERING AHMEDABAD LIQUID LEVEL MEASUREMENT
Leak Detection Equipment Tank Tightness Testing Overview Presented by C.J. Schultz Tanknology Inc.
Unit 11: Calibrating Instruments
Quick Start Guide for Flex Flow Pump
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
Maintenance Training Policy Changes
Leak Detection Equipment Tank Tightness Testing Ed Kubinsky Crompco
PADI Section 4 Breathing Air at Depth.
L12- FLUIDS [1] Stuff that flows. liquids gases sand.
CA05FS Owner’s Manual Fuel Cell Technology Breath Alcohol Tester.
L12- FLUIDS [1] Stuff that flows liquids gases sand.
14 Refrigerant Recovery, Recycling, and Recharging.
Flame Photometer BWB-XP
TEAM 2 – FALL 2006 PRESENTATION 1 LPM: Ahmad Omari.
Electronic Fuel Injection
L12- FLUIDS [1] Stuff that flows liquids gases sand.
Ritchie Yellow Jacket Instrument Applications
8.8 Partial Pressure (Dalton’s Law)
Forging new generations of engineers
L12- FLUIDS-1 Stuff that flows liquids gases sand.
Gas Laws Read pp
SF6 Reporting Challenges
L12- FLUIDS [1] Stuff that flows. liquids gases sand.
Precast Concrete Pipe and Box Culvert Equipment Calibration
Digital Chart Recorder Operation
Partial Pressure (Dalton’s Law)
Ocean Diver Supplementary Training
L12- FLUIDS [1] Stuff that flows liquids gases sand.
Leaky Appliance Trigger Rate
Homework Quiz Increasing which variable would decrease the pressure of a contained gas? Temperature b) number of particles Boiling point d) volume Boyle’s.
The fuel gauge in Paula’s car says that it has 15 miles to go until the car runs out of gas. There is a gas station 5 miles ahead. Unfortunately, when.
Automobile Emission Gas Analysis Solution
Automotive Technology Principles, Diagnosis, and Service
Distribution Student Task
REX Regulator (KM47/77).
Presentation transcript:

Gas Analysis for the Recreational and Technical Diver Joel D. Silverstein R.W. Bill Hamilton, PhD

OVERVIEW This workshop is an introduction to preparing oxygen enriched air. A Blending Technician should be certified to dive with the gas they intend to prepare. An Oxygen Service Technician should be certified by the manufacture to repair the scuba equipment they intend to convert to oxygen service. Initialy work with another technican until you feel comfortable working on your own.

EQUIPMENT LABELS Install a tank decal or wrap to identify the particular gas mixture; nitrox, trimix or O2. Install a contents-tag identifying the FO2 MOD, analysis date, fill pressure, and the analyzers/users initials. Use appropriate labeling for dedicated scuba regulators and gauges.

Identifying Enriched Air Cylinders 4 inch green band on yellow tank NITROX or Enriched Air stenciled in 2 inch high letters Non-yellow cylinders have an additional 1 inch yellow band above and below the green

Other identification labels Oxygen Service label designates cleanliness annually or if contaminated Visual Inspection annually or sooner Cylinder Contents identifies contents

ENRICHED-AIR SYSTEMS GAVIMETRIC METHOD Gavimetric mixing requires a sensitive scale that displays weight in 1/4 ounce increments up to 150 lbs. Eliminates mix variability from temperature and compressibility factors. Must know the volume of gas at ambient pressure for service rating of the cylinder. Scale and setup is expensive.

O2 ANALYSIS Analyze the cylinder contents before discharging it to the customer. Calibrate an analyzer to 100% O2 when the unit is new or the fuel cell is weak. Before analyzing gas, let the sensor equilibrate to ambient temperature and calibrate to dry air. Adjust flow rate to specifications and do not block the exit side of the flow tube.

Performing Gas Analysis overview Oxygen analyzers The need for calibration Need two analyzers ? Acceptable range Analyzing Gas Flow rate Calibration Analyzing the enriched air cylinder

Oxygen Analyzers Digital Analog 0.1% accuracy is desirable Electrochemical oxygen sensor has limited life span

The Need for Calibration Some units need a flow meter to be accurate Sets analyzer at a known value (air) Allows for adjustment of sensor deterioration Affected by flow rate Better to calibrate one well than to use two Air calibrates at 20.9% Calibrate on 100% when readings fluctuate

Analyzing the Gas Flow Rate Acceptable range affects reading the greater the pressure against the sensor the higher the value shown 1-2 Lpm for one minute calibrated at same flow Acceptable range desired mix +/- 1%

The Nitrox Cylinder Calibrate analyzer Analyze cylinder some auto calibrate Analyze cylinder Check for accuracy If not right recalibrate have gas re-mixed Write information contents label or tag

Contents Label and Fill Log Write on label Use permanent marker Fill date Oxygen % PSI (pressure) MOD Filled by Analyzed by User’s name Name Certification number Date Fill pressure Oxygen percentage Maximum depth limit Cylinder serial number Signature