Sensors and Detectors - 1

Slides:



Advertisements
Similar presentations
Mass Flow Controller. Function Delivers user specified flow rate of gas. Flow rate is mass flow rate (i.e. number of molecules per sec Mol/sec), not volume.
Advertisements

FLOW measurements.
Dynamic Behavior of Closed-Loop Control Systems Chapter 9.
CHAPTER V CONTROL SYSTEMS
HVACR312 - Refrigeration Metering Devices.
Section 5: Commercial Refrigeration
Booster System Basics: Constant Speed Systems
Pressure Sensors.
ACADs (08-006) Covered Keywords Calibrate, direct, inferred, transmitter calibration, gravity correction, density correction, hydrostatic head detector,
On-Line Physical Measurements Terry A. Ring Department of Chemical Engineering University of Utah.
SENSORS AND TRANSDUCERS
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
Classification of Instruments :
ACADs (08-006) Covered Keywords Flow rate, total flow, differential pressure, percent flow, cotameter, Bernouli. Description Supporting Material
Lesson 26 CENTRIFUGAL PUMPS
STEAM HEATING.
Hydronic Mechanical Controls
EXPERIMENTAL CLASS 3. FLOW MEASUREMENT
EKT314/4 Electronic Instrumentation
Lecture 3: Bridge Circuits
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
Temperature Measurement
Carburetor Systems.
Topic 1 different attributes that characterize sensors ETEC 6405.
Lease Automatic Custody Transfer
Chapter 27 Lecture 12: Circuits.
LECTURE#07 AUTOMATION PROCESS CONTROL
Experiment 2-1 Flow Generation Flow, as it is used in this course is defined as the movement of a fluid as measured in gallons per minute for liquids and,
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
R. Field 10/29/2013 University of Florida PHY 2053Page 1 Ideal Fluids in Motion Bernoulli’s Equation: The Equation of Continuity: Steady Flow, Incompressible.
Temperature Control Loop
Example 1 Velocity measurement by a Pitot tube
CHAPTER 9 Control System Instrumentation
CHAPTER 9 Control System Instrumentation
PRESSURE SENSORS  Pressure is an expression of the force required to stop a fluid from expanding, and is usually stated in terms of force per unit area.
Control System Instrumentation
FC Flow Control: Centrifugal pump with constant speed (rpm) Orifice plate sensor Globe valve FC Flow Control: Positive displacement pump Orifice plate.
HYDRAULICS & PNEUMATICS
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Lecture 3: Bridge Circuits
Valves, Instrumentation, and Control
ERT 322 SAFETY & LOSS PREVENTION. (A) Spring operated reliefs in liquid and gas service. (B)Rupture disc reliefs in liquid and gas service. (C)Vents for.
CHAPTER 9 Control System Instrumentation
Engineering 80 – Spring 2016 Temperature Measurements 1 SOURCE: 3_standardbody__to-226_straightlead.jpg SOURCE:
ABOUT INSTRUMENTATION Instrumentation is used in almost every industrial process and system, where consistent and reliable operations are required. Instrumentation.
Temperature and Pressure Sensors Seth Price Department of Chemical Engineering New Mexico Tech Rev. 10/27/14.
Heat Exchangers Results Josué Ortiz #57703 Prof: Eduardo Cabrera Me
Phil. U., M Eng Dep., Measurements, Chap#7 flow measurements is very important as it covers wide ranges of applications. The flow rate measurement devices.
Electric Pressure Transducer
UNDERSTANDING DIFFERENT
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
Operator Generic Fundamentals Components - Sensors and Detectors 1
Components Pumps.
Fluid Statics/Dynamics
MECH 373 Instrumentation and Measurements
Control System Instrumentation
Heat Exchangers and Condensers
Instrumentation Malfunctions, Test Review - Agenda
Figure 10.1 Flow in a duct with area change.
CHAPTER V CONTROL SYSTEMS
Controllers and Positioners
Bernoulli and his Principal of Airflow
Measurement of Pressure
Operator Generic Fundamentals Components - Sensors and Detectors 1
CENTRE OF EXCELLENCE (CHEMICAL SECTOR)
PEF3006 Process Control Fall 2017 Sensors By Finn Haugen
Control System Instrumentation
Control System Instrumentation
Presentation transcript:

Sensors and Detectors - 1 Components Sensors and Detectors - 1

1. If the steam pressure input to a density-compensated steam flow instrument fails high, the associated flow rate indication will... decrease, because the density input has decreased increase, because the density input has decreased decrease, because the density input has increased P305 Correct Answer: D

2. Flow rate is being measured using a differential pressure flow detector and a calibrated orifice. If actual flow rate remains constant, which one of the following will cause indicated flow rate to be higher than actual flow rate? The flow detector equalizing valve is inadvertently opened. A leak develops in the high pressure sensing line. Debris becomes lodged in the orifice. The orifice erodes over time. P706 Correct Answer: C

3. The flow rate of water passing through a venturi can be determined by measuring the... differential pressure of the water as it passes through the venturi. change in the velocity of the water as it passes through the venturi. linear displacement of a metering plug installed in the throat of the venturi. rotation rate of a paddle wheel-type device installed in the throat of the venturi P607 Correct Answer: A

4. A cooling water system is operating at a steady-state flow rate of 500 gpm with 60 psid across the associated venturi flow element. If cooling water flow rate increases to 1,000 gpm, the differential pressure sensed by the venturi flow element will be approximately... 85 psid. 120 psid. 240 psid. 480 psid. P1407 Correct Answer: C

5. A venturi is being used to measure the flow rate in a cooling water system. As the water flows from the throat to the discharge of the venturi, water pressure will __________; and volumetric flow rate will __________. increase; remain the same increase; decrease decrease; remain the same decrease; decrease P2306 Correct Answer: A

6. Refer to the drawing of a water storage tank with a differential pressure (D/P) level detection system (see figure below). A calibrated D/P level detector is being used to measure level in a vented tank inside the auxiliary building. If building pressure increases with no change in temperature, the associated level indication will... decrease, then increase and stabilize at the actual level. decrease and stabilize below the actual level. increase and stabilize above the actual level. remain at the actual level. P1108 Correct Answer: D

7. Refer to the drawing of a water storage tank with a differential pressure (D/P) level detection system (see figure below). The water storage tank is 40 feet tall. The level detection system is calibrated to provide a level indication of 30 feet when the tank and reference leg levels are equal. If the tank is completely filled with water, the tank level will indicate... less than 30 feet. 30 feet. greater than 30 feet, but less than 40 feet. 40 feet. P6604 Correct Answer: B

A bourdon tube works on the principle that when the pressure inside the tube decreases, the tube tends to: (Assume detected pressure remains above atmospheric pressure.) coil, due to an increased pressure-induced force on the outside of the tube. straighten, due to an increased pressure-induced force on the outside of the tube. coil, due to the spring action of the metal overcoming the pressure-induced force on the inside of the tube. straighten, due to the spring action of the metal overcoming the pressure-induced force on the inside of the tube. P1508 Correct Answer: C

Unlike a resistance temperature detector, a typical thermocouple... uses a single type of metal in the sensing element. requires a temperature-controlled reference junction. can provide temperature input to a valve controller in a cooling water system. requires an external power supply to provide indication of temperature. P2711 Correct Answer: B

10. Because of a thermocouple temperature display failure, the millivolt output of a thermocouple circuit is being converted to a temperature value using conversion tables. The tables are based on a thermocouple reference junction temperature of 32°F. The actual reference junction is located in a panel that is maintained at 120°F. Room temperature surrounding the panel is 80°F. What adjustment must be made to the temperature value taken from the conversion tables to calculate the actual temperature at the measuring tip of the thermocouple? Add 48°F. Subtract 48°F. Add 88°F. Subtract 88°F. P6504 Correct Answer: C