UV/VIS SPECTROSCOPY.

Slides:



Advertisements
Similar presentations
UV-Vis SPECRTOSCOPY.
Advertisements

Bragg’s Law nl=2dsinΘ Just needs some satisfaction!! d Θ l
SPECTROSCOPY.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Ultraviolet and Visible Spectroscopy Chemical Ideas 6.8.
Advanced Spectroscopy 2. UV-VIS Spectroscopy. Revision 1.What are the wavelength ranges for the ultraviolet and visible regions of the spectrum?  UV:
Atomic Absorption Spectroscopy (AAS)
Spectroscopy Chapter 7.
Lecture 19 Spectrophotometry- III. Light Source Sample Monochromator (filter, wavelength selector) Detector Spectrometer Data Processing.
Introduction to Spectrophotometry
Lecture 5. UV-VIS Spectroscopy. Ultraviolet and Visible Absorption Spectroscopy When matter absorbs electromagnetic radiation in the domain ranging from.
Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry Absorption measurements based upon ultraviolet and visible radiation.
Introduction to Instrumental Analysis - Spectrophotometry
Year 12 Chemistry Unit 3 – AOS 1 Chemical Analysis.
Fluorometric determination of riboflavin
Fluorometric determination of riboflavin. Introduction.
UV-Vis Absorption Spectroscopy
Infrared Spectroscopy
Simple Double Beam Spectrometer
Simple Double Beam Spectrometer
Determining the Concentration of a Solution: Beer’s Law
1 UV-Vis Absorption Spectroscopy Lecture Multichannel Instruments Photodiode array detectors used (multichannel detector, can measure all wavelengths.
Spectrophotometry.
Introduction to Spectrophotometry
1 UV-Vis Absorption Spectroscopy Lecture Measurement of Transmittance and Absorbance: The power of the beam transmitted by the analyte solution.
Asa Arjoon U6 Chemistry Presentation on Visible and Ultraviolet Spectroscopy Name : Form : Subject :
Introduction to Spectrochemical Methods
UV-VIS Spectroscopy Dr. AKM Shafiqul Islam.
INFRARED SPECTROSCOPY
Spectrophotometer.
SPECTROPHOTOMETRY. Spectrophotometry Determines concentration of a substance in solution –Measures light absorbed by solution at a specific wavelength.
SPECTROPHOTOMETRY. Principle : there is interaction between the light and sample particle, spectrophotometer is employed to measure the amount of light.
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Summary: (Last lecture) Absorption spectroscopy definition electromagnetic spectroscopy matter absorption spectroscopy fundamental terms (transmittance,
Fluorometric determination of riboflavin
Isaac Newton showed that a glass prism could be used to split sunlight into a spectrum in Further studies by William Wollaston in 1802 revealed.
Instrumentation. Chromatography Chromatography is the collective term for a set of laboratory techniques for the separation of mixtures. It involves.
Spectrophotometry at a Glance
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
ULTRAVIOLET AND VISIBLE SPECTROSCOPY
1 Instrumental Analysis Tutorial 2. 2 Objectives By the end of this session the student should be able to: 1.Describe the grating principle of work. 2.Describe.
Introduction to Spectrophotometry
Simple Double Beam Spectrometer
Lab1 A VISIBLE ABSORPTION SPECTROMETER
Chem. 133 – 3/14 Lecture.
Chromatography- TLC & HPLC
Laboratory equipment Lecture (4).
Spectroscopy Techniques
Beer-Lambert law Gihan Gawish.Dr.
Principles and practice of Spectrophotometer
Introduction to Spectrophotometry
Spectroscopy Chapter 7.
Colorimeters or photometers
Introduction to Spectrophotometry
Spectrophotometer Dr . S. Jayakumar.
RINCIPLE OF COLORIMETER AND SPECTOPHOTOMETER AND VARIOUS TYPE OF ANALYSER USED IN CLINICAL BIOCHEMISTRY.
Measurements involving light –A Basic Principles and Instrumentation
Experiments in Analytical Chemistry
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Electronic Spectroscopy Ultraviolet and visible
Organic Instrumentation
Instrumental Analysis
Light and Matter Main Concept:
Colorimeters OR photometers
SPECTROPHOTOMETRY Applied Chemistry.
Colourimetry The absorption of light by a coloured solution is directly related to the concentration of the solution. Colourimetry determines the concentration.
Advanced Pharmaceutical Analysis UV spectroscopy
Instrumentation.
Clinical instrumental analysis
Presentation transcript:

UV/VIS SPECTROSCOPY

Application Of Ultraviolet/Visible For IDENTIFICATION AND ESTIMATION of inorganic, organic and biomedical species Is employed primarily for QUANTITATIVE ANALYSIS The function of this instrument is relatively straightforward.

TYPE OF MEASUREMENT The ultraviolet (UV) region scanned is normally from 200 to 400nm, and the visible portion is from 400 to 800nm. Uses a light source emitting in the visible spectrum Two types :single beam and double beam Single beam : requires prior calibration using a standard control Double beam : simultaneously measures the sample and the standard control

Absorbance may be presented as TRANSMITTANCE (T=I/I0) or ABSORBANCE The most commonly used solvents are water, ethanol, hexane and cyclohexane. Absorbance may be presented as TRANSMITTANCE (T=I/I0) or ABSORBANCE (A= log I0/I) The wavelength of maximum absorbance is a characteristic value, designated as λmax The intensity of the reference beam, which should have suffered little or no light absorption, is defined as, I0 The intensity of the sample beam is defined as I

Single beam All the light passes through the sample Measure intensity of the incident light Less expensive Less complicated

Double Beam Light source split into two separate beams Passes through the sample Used for reference

Single beam

Double beam

OPERATING PRINCIPLE Measures a material light reflection, transmission or absorbtion properties. Measure the spectrum of a compound. Operates by passing a beam of light through a sample. Measuring the intensity of light reaching a detector. Spectrum is a graph of intensity of absorbed or emitted radiation by sample verses frequency or wavelength

TEST RELATED Used in analytical chemistry for the quantitative determination of different analytes, such as transition metal ions, highly conjugated organic compounds, and biological macromolecules. Spectroscopic analysis is commonly carried out in solutions but solids and gases may also be studied.

TEST RELATED Variables must be controlled : The nature of the solvent The pH of the solution Temperature High electrolyte concentrations The presence of interfering substances can influence the absorption spectrum

TEST RELATED DMF (dimethylformamide) THF (tetrahydrofuran) ACETONE H20 ETHANOL

TEST RELATED used in the semiconductor industry to measure the thickness and optical properties of thin films on a wafer. UV-Vis spectrometers are used to measure the reflectance of light Can be analyzed via the Forouhi-Bloomer dispersion equations to determine the Index of Refraction (n) and the Extinction Coefficient (k) of a given film across the measured spectral range.

Film on water

SAMPLE OF TEST The sample compartment provides a light-tight environment that limits the addition of stray radiation. Samples are normally in the liquid or solution state, and are placed in cells constructed with UV/Vis transparent materials, such as quartz, glass, and plastic.

SAMPLE OF TEST From left to right (with path lengths in parentheses): rectangular plastic cuvette (10.0 mm), rectangular quartz cuvette (5.000 mm), rectangular quartz cuvette (1.000 mm), cylindrical quartz cuvette (10.00 mm), cylindrical quartz cuvette (100.0 mm).

SAMPLE OF TEST If we need to monitor an analyte’s concentration over time, it may not be possible to physically remove samples for analysis. Examples : Monitoring industrial production lines or waste lines Monitoring a patient’s blood Monitoring environmental systems

SAMPLE OF TEST Fibre optic probe

ADVANTAGES rapid means of analysis can provide very high precision and accuracy. It is useful for a wide variety of chemicals, and it is non-destructive. It can be used both quantitatively and qualitatively on pure substances.

DISADVANTAGES limited use in analysing mixtures, due to the addition of absorbance. It requires special equipment (a UV light source and UV-transparent sample holders, for example) it is not selective for compounds if they absorb at the same wavelength.

ADVANTAGES DISADVANTAGES System lies in the simplistic design of the instrument. The shutter is the only moving component of a UV-VIS spectrometer. LIGHT SOURCE No single lamp emits all the light wavelengths necessary for analysis. Changing the lamp is a time-consuming process. very quick process compared to other methods of sample detection, such as HPLC. This rapid analysis is achieved only through proper calibration. CALIBRATION require frequent calibrations to retain the accuracy and precision of the instrument. requires the knowledge of the type of sample being analysed. technique is non-destructive to the sample and has a high sensitivity for detecting organic compounds. SENSITIVITY user trying to detect the sample using too wide of a wavelength range or by poor instrument design, cause stray light to occur.