Use of the ICare Home Rebound Tonometer for home self-monitoring of intraocular pressure in a Singaporean population Jeanne Joyce OGLE1, Wai Cheng SOO.

Slides:



Advertisements
Similar presentations
A Wireless, Implantable Intra- Ocular Pressure Sensor for the Management of Glaucoma Gabriel Simon, M.D. Ph.D. Sept 16, 2008 ESCRS.
Advertisements

A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
Recent Advances in IOP measurements
Comparison between Dynamic contour tonometry, Goldmann applanation tonometry and Ehlers-corrected Goldmann applanation tonometry in eyes after Laser In.
Comparison of corneal astigmatism measured with 3 devices Mariko Shirayama, M.D, Li Wang, M.D, PhD, Mitchell P. Weikert, M.D, Douglas D. Koch, M.D. Cullen.
Sample size calculations
SEI IOP and its correlations in a population based study in Central India. The Central India Eye and Medical Study. Krishna Bhojwani, Vinay Nangia, Jost.
Comparison of the Diaton Transpalpebral Tonometer Versus Goldmann Applanation R. S. Davidson 1 ; N. Faberowski 2 ; R. J. Noecker 3 ; M. Y. Kahook 1 1.
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
Will my Glaucoma patient lose vision ?
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Purpose: Introduction:  At initial evaluation: For post-op day # 0 patients: Pre-op VA was 20/50.6 (0.395 ± 0.198); Post-op VA was 20/102.0 (0.196 ± 0.162);
Presents: Diaton Tonometer Tonometry through the Eyelid! September 2006.
Glaucoma Screening With a New Non-Contact Air Impulse Tonometer Pandelis A. Papadopoulos,1,2, Dimitrios P. Bessinis 3, Alexandros A. Papadopoulos 1, Konstantinos.
Glaucoma and Penetrating Keratoplasty : Incidence, Risk Factors, and Outcomes Sonika Gupta Consultant Ophthalmology Max Eye Care New Delhi, India Author.
Cataract Surgery After Trabeculectomy: The Effect on Trabeculectomy Function Husain R, Liang S, Foster PJ. Cataract surgery after trabeculectomy: the effect.
One-arm reach (heels down example) Two-arm reach (heels up example) Conclusions Highest reliability for all age groups was in the toe-to-finger method.
Comparison of the Diaton Transpalpebral Tonometer Versus TonoPen- Applination Theodore H. Curtis, M.D.1, Douglas L Mackenzie, M.D.1, Robert J. Noecker.
A Prospective Trial Comparing Pneumotonometry of Cornea and Sclera Usiwoma Abugo BS 1, Sara Duke MD 2, Shuchi Patel, MD 2 1 Loyola University Chicago,
The effect of corneal edema on intraocular pressure measurements after phacoemulsification surgery Ilker Eser M.D. 1 Arzu Taskiran-Comez M.D. 1 Baris Komur.
Visual and IOP Outcomes after PRK in Pigment Dispersion Syndrome [Poster Number: P190] Kraig S. Bower, Denise A. Sediq, Charles D. Coe, Keith Wroblewski,
Rate of Visual Field Progression in Eyes With Optic Disc Hemorrhages in the Ocular Hypertension Treatment Study De Moraes CG, Demirel S, Gardiner SK, et.
Comparing Factors Affecting Surgically Induced Astigmatism
Minimizing Risk in Visian ICL Implantation.
The Royal Victorian Eye and Ear Hospital 24-hour eye pressure and glaucoma Dr Simon Skalicky FRANZCO, MPhil, MMed (Ophthal Sci), MBBS (Hons 1) Visiting.
Genetic Susceptibility Variations and Visual Field Progression in Singaporean Chinese Patients with Primary Angle Closure Glaucoma 1 Duke-National University.
The Efficacy and Safety of the Low Intensity Ultrasound Treatment in Patients with Open Angle Glaucoma Hyoung Won Bae, Gong Je Seong, Chan Yun Kim Institute.
Copyright © 2011 American Medical Association. All rights reserved.
CRF variations ( initial CRF – final CRF )
Tulsi Changulani 1,*, Jenny Bo 2, Mei-Ling Cheng 1, Andrew Tatham 1
Selective laser trabeculoplasty in Korean eyes with medically uncontrolled pseudoexfoliation glaucoma Su Chan Lee1, Jung Hyun Lee1,
Ophthalmology – Raised IOP Referrals (Adults only)
Comparison of Endothelial Cell Loss After Phacoemulsification Performed by Third Year Residents and Anterior Segment Surgeons Alexandra Braunstein, MD.
Effect of Primary Phacoviscocanalostomy / Viscocanalostomy On Intraocular Pressure Of Normal Tension Glaucoma Patients: 3-Year Results Derek Ho¹, Adesuwa.
Factors Influencing Patient Satisfaction in a Glaucoma Population
Parental Alcoholism and Adolescent Depression?
Day-to-day variability in older adults' physical activity:
Pharmacological and Behavioral
From: Morphometric Changes in the Rat Optic Nerve Following Short-term Intermittent Elevations in Intraocular Pressure Invest. Ophthalmol. Vis. Sci ;51(12):
Number of Days of Monitoring Needed with Accelerometers and Pedometers to Obtain Reliable Estimates of Habitual Physical Activity in Adults T. S. Robinson,
IOP = intraocular pressure; SD = standard deviation.
Copyright © 2013 American Medical Association. All rights reserved.
Date of download: 12/25/2017 Copyright © ASME. All rights reserved.
ComQuol: Service Focused Outcomes
Reliability and Validity of the Arabic Activities-specific Balance Confidence Scale in People with Multiple Sclerosis Alia Alghwiri1, Hanan Khalil2, Alham.
ABSTRACT PRESENTATION Marcus Vinicius Nascimento-Ferreira
Statistics in Applied Science and Technology
R. S. Davidson1; N. Faberowski2; R. J. Noecker3; M. Y. Kahook1 1
Johnson CH TAN, MBBS, MRCSEd(Ophthalmology)
Comparison of corneal powers obtained from four different devices
2/24/2013.
JAMA Ophthalmology Journal Club Slides: Outcomes of the Veterans Affairs Low Vision Intervention Trial II Stelmack JA, Tang XC, Wei Y, et al; LOVIT II.
Natalie Robinson Centre for Evidence-based Veterinary Medicine
Screening, Sensitivity, Specificity, and ROC curves
Comparison of Automated and Manual Measurements of Horizontal Corneal Diameter in Contact Lens Wearers Using Orbscan Eye Metrics Function and Orbscan 11z.
Associate Professor of Ophthalmology
Federal University of São Paulo, Brazil
JMP 11 added new features and improvements to CCB and MSA.
Good morning, ladies and gentlemen. Please let me introduce myself
Yakov Goldich MD,Yaniv Barkana MD, Isaac Avni MD, David Zadok MD,
Evaluation.
Intermediate methods in observational epidemiology 2008
Effect of Sample size on Research Outcomes
Gary Morse, Ph.D. Mary York, LMSW Nathan Dell, AM, LMSW
Mohamed Abdelrahman Awadalla,FRCS Magrabi Eye Hospital Cairo - Egypt
Hyuck Jin Choi, Joo Youn Oh, Won Ryang Wee, Mee Kum Kim,
Jun Her MD. PhD, Sung-wook Kim MD, Jae-hwan Ahn MD
The Effect of Corneal Thickness on Ocular Drug Penetration
ESCAPE Pain The Northumbria Challenge
Box and whiskers plot for bIOP, Goldmann applanation tonometry IOP (GAT) and Goldmann adjusted (GATAdj) in ocular hypertension (OHT), primary open-angle.
Presentation transcript:

Use of the ICare Home Rebound Tonometer for home self-monitoring of intraocular pressure in a Singaporean population Jeanne Joyce OGLE1, Wai Cheng SOO HOO1, Angela Peck Hoon LIM1, Leonard Wei Leon YIP1 1 National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore Introduction Results […continued] Management of glaucoma is largely based on measurement of intraocular pressure (IOP) with treatment aimed at lowering IOP. Unfortunately ‘snap-shot’ IOP measurement in the glaucoma clinic at a given point of time is not at all reflective of IOP trends throughout the day. Short of continuous IOP monitoring, intermittent home self-monitoring of IOP over a period of time could possibly provide invaluable information on IOP trends. This would give clinicians a better understanding of the individual patient, thus facilitating better management of the disease. On univariate analysis, there was no statistically significant impact of age, gender, central corneal thickness, visual acuity or severity of glaucoma on the accuracy of the patient’s ICare readings. Intraclass correlation coefficient (ICC) between ICare Home readings obtained by the study team and the patients at the first visit was 0.719 (95% confidence interval (CI) 0.317-0.890) for the right eye, and 0.708 (95% CI, 0.406-0.872) for the left eye. ICC at the final visit was 0.77 (95% CI, 0.504-0.903) for the right eye, and 0.838 (95% CI, 0.638-0.932) for the left eye. There was reasonably good agreement between the study team and patient readings, especially at the final visit. Test-retest variability did not show any significant trend over the 7-day period for either eye. From questionnaire responses 65% of patients agreed the device is easy to use although only 37% could get the reading at their first attempt. 89% of the patients would recommend the device to other glaucoma patients. Objectives Our primary objective is to establish whether Singaporean patients can perform accurate and reliable home self-monitoring of their IOPs using the ICare Home Rebound Tonometer. Methodology 20 patients attending glaucoma subspecialty clinics were enrolled. The study team first measured the patient’s IOPs using the Goldmann applanation tonometer (GAT) and the ICare Home. These readings were recorded to be compared. The patients were then trained to use the ICare Home and their readings recorded to be compared with the study team’s readings. The ICare Home device was then loaned to the patients for a period of 7 days. During the loan period, patients measured their IOPs for both eyes twice a day, taking 3 readings each time. A week later, GAT & ICare readings were again taken by the study team and the patients. All the IOP readings over the week and at the final visit were downloaded and analysed. Bland-Altman difference analysis was used to assess the agreement between GAT and ICare Home readings taken by the study team. Intraclass correlation (ICC) compared the ICare Home measurements by the study team and the patient. Test-retest variability for the patient's readings over the 7-day period were analysed by taking the standard deviation of the 6 readings taken per day. A questionnaire was also administered at the conclusion of the study to assess the patient's experience with the device. Discussion Our study shows that a fair proportion of our patients can be trained to use the ICare Home device with fairly accurate readings obtained after just one training session and this is not limited by age, severity of glaucoma or visual acuity. There does appear to be a bit of a learning curve despite the test-retest variability demonstrating no significant trend in the readings taken over a 7-day period as there is some improvement in accuracy at the end of the loan period as compared to the initial session. Granted the ICare Home slightly over-estimated IOP compared with GAT, but the overall trends recorded would still provide valuable information to the clinician. Perhaps more importantly, the device was well received by patients who agree that it is portable and easy to use. Results Conclusion Singaporean patients are able to perform reasonably accurate self-tonometry using the ICare Home tonometer following a short period of training although readings are generally slightly over-estimated compared with GAT. Reasonably good agreement was demonstrated between IOP readings obtained by the study team using the GAT and ICare Home with 95% of differences between the two measurement methods falling within the limits of agreement. ICare Home readings were generally slightly higher for both eyes compared with GAT. Mean bias ranged from 1.7 to 2.3 mm Hg right eye, and 1.4 to 1.85 mm Hg left eye. At the first visit, 13 patients (68%) could perform fairly accurate self-tonometry on their right eye (obtaining readings within 2mm Hg of the study team readings), and 11 patients (55%) on their left eye. At the final visit, this increased to 14 patients (70%) for the right eye and 15 patients (75%) for the left eye. References 1. Fernandes P, Diaz-Rey JA, Queiros A et al. Comparison of the ICare rebound tonometer with the Goldmann tonometer in a normal population. Ophthal. Physiol. Opt. 2005;25:436-440 2. Abraham LM, Epasinghe NCR, Selva D et al. Comparison of the ICare rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists. Eye 2008;22:530-536 3. Asrani S, Chatterjee A, Wallace DK et al. Evaluation of the ICare Rebound Tonometer as a Home Intraocular Pressure Monitoring Device. J. Glaucoma 2011;20(2):74-79 4. Dabasia PL, Lawrenson JG, Murdoch IE. Evaluation of a new rebound tonometer for self-measurement of intraocular pressure. Br J Ophthalmol 2016;100(8):1139-1143 Email: jeanne_ogle@ttsh.com.sg