Maria’s Restaurant Chapter 2 Section 9

Slides:



Advertisements
Similar presentations
Heating, Ventilating, and Air-Conditioning
Advertisements

100% Outside Air and Dehumidification Management
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Heating and Air Conditioning I
Introduction Enthalpy Wheel
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
MOLLIER DIAGRAM.
Psychrometric Chart Basics
Airflow Properties & Measurement
The House as a System 1. Air Temperature and Water Vapor.
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
Best Direction System Ltd.
Product Introduction.
Department of Mechanical Engineering ME 322 – Mechanical Engineering Thermodynamics Lecture 35 Analysis of Air Conditioning Processes.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
General Troubleshooting Tips.
Copyright Mestek, Inc What’s High Velocity Air Conditioning?
Important variables Water: Air: Conversion:
Objectives Define psychrometric quantities Continuation from previous class Draw psychrometric processes Relate psychometric variables to human comfort.
A Trane Air Conditioning Clinic Psychrometry Air Conditioning Clinic TRG-TRC001-EN © American Standard Inc
Pressure-Enthalpy and the Variable Refrigerant Cycle
HEATING AND COOLING SYSTEMS
AIR CONDITIONING (COOLING)
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
HCB 3-Chap 19A: All-Air Systems_Single Zone 1 Chapter 19A: ALL-AIR SYSTEMS: SINGLE ZONE AND SINGLE DUCT Agami Reddy (July 2016) 1)Introduction and common.
SECTION 7 AIR CONDITIONING (COOLING) UNIT 35 COMFORT AND PSYCHROMETRICS.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Maria’s Restaurant Chapter 2 Section 6
Maria’s Restaurant Lesson 18 Appendix A Zone 2 Equipment Loads
Maria’s Restaurant Lesson 21 Appendix C Duct Design
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
Maria’s Restaurant Chapter 2 Section 7
Maria’s Restaurant Chapter 1 Section 4
Maria’s Restaurant Chapter 1 Section 3
Maria’s Restaurant Chapter 3 Section 13
Maria’s Restaurant Chapter 4 Section 15
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Lesson 24 Appendix F Outside Air Calculation
Maria’s Restaurant Chapter 1 Section 5
Doug Jefferson, Business Development Engineer
Ritchie Yellow Jacket Instrument Applications
Maria’s Restaurant Chapter 2 Section 8
Heat loss and heat gain in buildings: Outside air (OA) (Additional information) Required to be brought inside a building envelope to continuously replace.
Psychrometric Chart Basics. Basic Concepts Saturation Line.
Psychrometric Processes
Munters DOAS, Chilled Beams and VRV
Maria’s Restaurant Chapter 3 Section 12
Variable Frequency Drive (VFD)
HCB 3-Chap 19A: All-Air Systems_Single Zone
Maria’s Restaurant Chapter 4 Section 14
Psychrometry & Air-conditioning
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
Zoning Load Calculations
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Zoning Methods There are an unlimited number of ways to zone a home! Popular ways include: More than one single zone HVAC system. Zone damper systems.
Mandatory Design Requirements
Excess Air Management Overview
FBE03: Building Construction & Science
Lecture Objectives Review: Psychrometrics (chart and quantities)
Lecture Objectives Learn about Psychrometric Chart Quantities
Objective Revie the Cooling Cycle Learn about air distribution systems
Maria’s Restaurant Chapter 1 Section 3
Maria’s Restaurant Chapter 3 Section 12
Maria’s Restaurant Chapter 2 Section 7
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Chapter 2 Section 8
Lesson 24 Appendix F Outside Air Calculation
Maria’s Restaurant Chapter 1 Section 5
Presentation transcript:

Maria’s Restaurant Chapter 2 Section 9

Latent Capacity Question 1 Using Table 9C on Page 38 in Maria’s Restaurant Guide & Workbook, will the total latent capacity in Btuh for the XHP 10-86Z in operating in high speed with a return air wet bulb temperature of 67OF and a fan CFM of 4,800 with a 85OF outdoor dry bulb temperature be equal to or above a latent heat removal requirement of 12,000 Btuh?

Table 9C Latent Capacity

Table 9C Latent Capacity 1 From the chart: at 4,800 CFM & Dry Bulb 85OF the sensible over total heat ratio is 0.97 thus, with a total capacity of 137.8 Btuh our latent capacity would be 137.8 × (1- 0.97) = 4,134 Btuh of latent heat capability Thus, the equipment would not meet the requirements at that fan speed.

Latent Capacity Question 2 What if the fan speed in the previous problem above was lowered to provide 4,000 CFM? From the chart: at 4,000 CFM & 85OF the sensible over total heat ratio is 0.90 thus, with a total capacity of 133,200 Btuh our latent capacity would be 133,200 × (1- 0.90) = 13,320 Btuh of latent heat capability Thus, the equipment would meet 12,000 Btuh the requirements at that fan speed.

kW Question Using Table 9C on Page 38 in Maria’s Restaurant Guide & Workbook, find the motor design load in kW and W for the XHP 10-86Z in operating with an outdoor air temperature at the condenser of 85OF and a fan CFM of 4,000.

Table 9C Latent Capacity 7.55 kW and 7,550 W

Dehumidification Implications When the building’s design SHR is high (0.85 or more), it will be relatively easy to select cooling equipment that will control indoor humidity in cooling mode. If the building’s SHR is medium (0.80 to 0.85), then there is more humidity (latent load) to deal with, and it becomes more important to select cooling equipment that will control indoor humidity. When the SHR is low (0.80 or less), there is an unusually large latent load and it may not be possible to find (standard) cooling equipment that will completely control the indoor humidity. Supplemental dehumidification may be necessary.

Dehumidification Implications Since the sensible restaurant cooling (50,185 Btuh) load divided by the total restaurant (71,666 Btuh) cooling load is 0.70 SHR level and the selected equipment operating range is also below 0.69 SHR in the OEM’s tables. Thus, there could be a problem with humidity control. Thus, Maria decided to have room for dehumidification equipment left in the duct design for the dinning side of the restaurant in case high humidity becomes an issue during the restaurant’s 1st year of operation.

Dehumidification Implications Finally, by selecting the lowest fan CFM, the designer assured airflow across the coil would be minimized and the humidity removal would be maximized. The coil surface area from the OEM tables is 12.8 ft2. Thus, with 2,400 CFM of airflow, and a coil with a surface area of 12.8 ft2 the velocity through the coil in feet per minute (FPM) can easily be calculated: 2,400ft3 ÷ 12.8 ft2.= 187.5 FPM this is a very low value but it is within the acceptable operating range for the 7.5-ton rooftop package heat pump selected. (Note: the old rule of thumb of 400 CFM per ton would put you at 3,000 CFM in the center of the chart.)

Comfort Question Figure 16 on page 41 shows a Psychrometric chart with the human comfort zone shown in red stripes. If we measured a room at 70 OF with a relative humidity of 30% would most people feel comfortable sitting in that room.

Comfort Question 1 No, due to the low humidity the room would feel cold to most people.

Equipment Selection Check List

Field Notes Page 1 A comfortable temperature is subjective and a few people in a room may never be comfortable even when the room temperature and humidity are dead center on the comfort chart. Some will say it is too hot, others will say it is too cold. Thus, Technician’s should know where they are on the comfort chart before changing the temperature based on one complaint or, they may be back with six more!

Field Notes Page 2  One blower motor variable frequency drive (VFD) setting related problem commonly encountered is: At lower speeds, the blower may not provide the required minimum replacement air volumes for the hoods. Thus, the restaurant will become in a low pressure with regards to the outside (making the inswing doors hard to close due to the air they are sucking in).

Field Notes Page 3 One Compressor motor variable frequency drive (VFD) related problem commonly encountered where a constant volume of airflow is required to make up for kitchen hood exhaust air is: due to the higher velocity of air with regards to the refrigerant in the coil the ability to remove moisture from the air being brought in is greatly decreased under most operating conditions (resulting in a much higher humidity inside the building than is outside and possibly a wet dog or mold smell in the building).