Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: An Open Loop Pulsating Heat Pipe for Integrated Electronic Cooling Applications J. Heat Transfer. 2014;136(8): doi: / Schematic of an integrated chip in a PCB substrate Figure Legend:
Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: An Open Loop Pulsating Heat Pipe for Integrated Electronic Cooling Applications J. Heat Transfer. 2014;136(8): doi: / Schematic of (a) an open looped heat pipe and (b) a closed loop heat pipe Figure Legend:
Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: An Open Loop Pulsating Heat Pipe for Integrated Electronic Cooling Applications J. Heat Transfer. 2014;136(8): doi: / PCB with integrated OLPHP Figure Legend:
Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: An Open Loop Pulsating Heat Pipe for Integrated Electronic Cooling Applications J. Heat Transfer. 2014;136(8): doi: / (dp/dT) sat of various working fluids over a range of operating temperatures Figure Legend:
Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: An Open Loop Pulsating Heat Pipe for Integrated Electronic Cooling Applications J. Heat Transfer. 2014;136(8): doi: / Experimental setup Figure Legend:
Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: An Open Loop Pulsating Heat Pipe for Integrated Electronic Cooling Applications J. Heat Transfer. 2014;136(8): doi: / Exploded view of the test section Figure Legend:
Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: An Open Loop Pulsating Heat Pipe for Integrated Electronic Cooling Applications J. Heat Transfer. 2014;136(8): doi: / Temperature difference between evaporator and condenser as a function of applied heat flux for ethanol, Novec 649 and Novec 7200 for FR = 70% and 90 deg orientation Figure Legend:
Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: An Open Loop Pulsating Heat Pipe for Integrated Electronic Cooling Applications J. Heat Transfer. 2014;136(8): doi: / Temperature difference between evaporator and condenser as a function of applied heat flux for ethanol and Novec 649 at 90 deg orientation across a range of fill ratios Figure Legend:
Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: An Open Loop Pulsating Heat Pipe for Integrated Electronic Cooling Applications J. Heat Transfer. 2014;136(8): doi: / Temperature difference between evaporator and condenser as a function of applied heat flux for ethanol and Novec 649 for FR = 30% and varying orientation angle Figure Legend:
Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: An Open Loop Pulsating Heat Pipe for Integrated Electronic Cooling Applications J. Heat Transfer. 2014;136(8): doi: / Thermal resistance for Novec 649 at 90 deg orientation and three fill ratios Figure Legend: