Victor MP:13818224729, website: INNOVATIVE SENSOR TECHNOLOGY Flow Sensors.

Slides:



Advertisements
Similar presentations
Load Cell &DP Cell 2007-CHEM-17.
Advertisements

Thermostats, Pressure Switches, and Other Electric Control Devices
Marketing NeSSI™ Globally What’s the Plan?. Issues There are periodic requests for NeSSI™ information from the “press” Should we provide directed mailings.
Resistance. Definition Opposition to the flow of electrons When electrons pass through materials with high resistance, they collide with its molecules.
Current and Resistance FCI.  Define the current.  Understand the microscopic description of current.  Discuss the rat at which the power.
Chapter 27: Current and Resistance Reading assignment: Chapter 27 Homework 27.1, due Wednesday, March 4: OQ1, 5, 14 Homework 27.2, due Friday, March 6:
Wind Instrument Testing Apparatus Project WITAP Team: Rob Koch Andy Lawrence.
1 Fall 2004 Physics 3 Tu-Th Section Claudio Campagnari Lecture 15: 18 Nov Web page:
Self-Induction Transducers ~ AC Supply v ref Inductance Measuring Circuit x (Measurand) Ferromagnetic Target Object Coil is activated by the supply and.
PH4705/ET4305: A/D: Analogue to Digital Conversion
Actuators & Their Applications
Electricity refers to the presence of electric current in wires, motors, light bulbs, and other devices. Electricity carries power. Power (P)
Sensors and Actuators John Errington MSc. Sensors and Actuators Sensors produce a signal in response to a change in their surroundings e.g. Thermostat.
Cogeneration.
Measurements in Fluid Mechanics 058:180:001 (ME:5180:0001) Time & Location: 2:30P - 3:20P MWF 218 MLH Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor:
EKT314/4 Electronic Instrumentation
Temperature Measurement
Electric (conduction) current I I According to general agreement its direction is chosen to coincide with the direction in which positive.
PH4705/ET4305: A/D: Analogue to Digital Conversion Typical Devices: Data sheets are on the web site for A/D 8 bit parallel AD7819 and serial ADC0831 And.
Slide # 1 Velocity sensor Specifications for electromagnetic velocity sensor Velocity sensors can utilize the same principles of displacement sensor, and.
ACOE2551 Microprocessors Data Converters Analog to Digital Converters (ADC) –Convert an analog quantity (voltage, current) into a digital code Digital.
Temperature Control Loop
 I1I1   R R R I2I2 I3I3 Lecture 11 Current & Resistance.
Seminar ON SMART SENSOR Submitted by : SUBIR KUMAR GHOSH Roll No. IN-14/04 Electrical & Instrumentation Deptt. B.E 7th Semester JORHAT ENGINEERING COLLEGE,
VIP4Air - VIP4Air/Slave Minimal Air/Oil Micro-lubrication Product Features and Operation Dave Stoyanoff - Dropsa USA.
Control System Instrumentation
EXAMPLE 27.1: A copper wire carries a current of 10 A. It has a cross- sectional area of 0.05 cm 2. Estimate the drift velocity of the electrons.
Electricity did not become an integral Part of our daily lives until Scientists learned to control the Movement of electric charge. This is known as.
CISSP Common Body of Knowledge Review by Alfred Ouyang is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 Unported License.
Mondady Feb. 10, 2014PHYS , Dr. Andrew Brandt 1 PHYS 1442 – Section 004 Lecture #8 Monday February 10, 2014 Dr. Andrew Brandt CH 18 Electric Power.
Potential Dividers and their application as sensors Electricity Lesson 9.
Voltage Divider Circuits Input transducers Input transducers are devices that convert a change in physical conditions (for example, temperature) into a.
WHEATSTONE BRIDGE OVERVIEW APPLIED APPROACH! Wheatstone Bridge Overview Learning Module.
BATCH MEMBERS R.ABHISHEK-08N41A0401 K.DHEERAJ REDDY-08N41A0412 S.RAJENDRA REDDY-08N41A0458 JYOTHISHMATHI COLLEGE OF ENGINEERING AND TECHNOLOGY,TURKAPALLY.
Transducers Topics covered in this presentation:
Product Overview Analogue Input, 2fold, SM  Box  Sensor connections
Government Engineering College
Temperature sensors Temperature is the most often-measured environmental quantity. This might be expected since most physical, electronic, chemical, mechanical,
Control System Instrumentation
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
ARDUINO BASED AUTOMATIC TEMPERATURE BASED FAN SPEED CONTROLLER
Thermo-electric refrigeration.
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Temperature Measurement
Transducers Topics covered in this presentation:
Basics of Sensor Compensation for Piezoresistive Sensors
Energy balance for the compressor in this figure:
INDUSTRIAL HYDRAULICS
Medical Electronics - K.Srinivasamoorthi
MECH 373 Instrumentation and Measurements
MECH 373 Instrumentation and Measurements
PNEUMOTACHOMETERS.
Chapter 27. Current and Resistance
VISUAL AIDS for instruction in VACUUM TECHNOLOGY AND APPLICATIONS
Instrumentation & Measurement (ME342)
Objectives Learn about Cooling towers Cooling cycles.
Pressure Level Sensor OTT PLS
Control System Instrumentation
Effects of moving charges
Differential Scanning Calorimetry
Customer Presentation
Customer Presentation
Chapter 27. Current and Resistance
Chromatography Daheeya Alenazi.
PNEUMOTACHOMETERS.
Chapter 27. Current and Resistance
Chemical Engineering Department
Chapter 27: Current and Resistance
Measurement of Motion.
PNEUMOTACHOMETERS.
Presentation transcript:

Victor MP: , website: INNOVATIVE SENSOR TECHNOLOGY Flow Sensors

Background Traditional IST Products: Temperature Thin Film Sensors Flow Sens = more than 1 T-Sensor on 1 Chip 

Working Principal Cooling of a heated resistance. The higher the flow, the better the cooling. - Heat transfer coefficient sensor-medium is dependent on flow velocity - The higher the flow, the more molecules passing the sensor, carrying away the heat. Flow Sensor Heat transfer  flow

FS1 Family Layout R heater R sensor Common 7mm 2.4mm 2 Elements on 1 Chip: - 1 current heated (45 0°C) - 1 reference element (1200 0°C)

FS1 Family Advantages Gases FS1 / FS1A Liquids FS1L / FS1LA - Large operation range - easy to build in - insensitive to contamination - no mechanical moving parts - high chemical resistance

FS1 Family Applications - extraction systems - compressed air control - HVAC - dosage of gases - cooling circuit controls - heating systems - pump controls - food industry Gases FS1 / FS1A Liquids FS1L / FS1LA

FS1 Family Evaluation R S R 1 R H V1 V2 R 2 R 3 V U_Bs GND Sensor Control of U_Bs  dT = const. dT = Temperature difference T(R H ) – T(R S ) To ensure constant dT, V1-V2 is controlled to 0. R1 is necessary to compensate the temperature difference  U_Bs = proportional to the mass flow

FS1 Family Output signal Gas flow up to 100m/s (const. dT=30K, Channel  2mm, G=100) Gas flow laminar (const. dT=30K, Channel  4mm, G=100)

FS1 Family Detecting air bubbles

FS1 Family Test Kit  4 Sensors: 2 FS1 and 2 FS1A or 2 FS1L and 2 FS1LA  Electronic (Housing 80x80x35mm)  RS232 cable  Power supply 15V  Software (CD) Start up Kit for flow measuring technology with FS1-Family - Analogue output - Serial interface

FS2 Family Layout 3 or 4 elements on 1 Chip: - 1 current heated (25 0°C) - 2 measuring elements (250 0°C) - FS2T: 1 reference element (550 0°C)

FS2 Family Applications: - differential pressure sensors - filter monitoring - over pressure cleanroom - directional switch Advantages: - very small flow <1m/s - detect direction - FS2T with additional T-Sensor for higher flow

FS2 Family Evaluation FS2 : VCC = const. V Heater = const.  V1-V2 proportional to the mass flow incl. detection of flow direction  for small mass flows only FS2 T: Control V Heater - R Ref const dT According to evaluation FS1  U Bs proportional to the mass flow  V1-V2 detection of flow direction R S left R1R1 R S right V1V2 R2R2 V VCC GND

FS2 Family Output signal air flow direction small air flow

microflowSens TM System - 4 resistive elements on one Chip (full bridge) - Measuring elements on organic membrane - Glass carrier results in a robust system and easy handling - Positioning holes allow positioning + electrical connection

microflowSens TM Advantages - Fast response time (<10ms) - Measuring of small mass flows - Detection of direction - Simple electronical analysis - Best price - performance ratio

microflowSens TM Applications - Differential pressure sensors - Medical devices (e.g. artificial respiration) - HVAC and building control solutions

microflowSens TM Evaluation VCC = constant (approx. 5V)  V1-V2 proportional to mass flow incl. detection of direction  just for small mass flows suitable

microflowSens TM Evaluation Typical Characteristic ± 0.8 m/s