Digital Multifunction Protection. INDEX 1.Key Features 2.Protection 3.Automation & Control 4.Metering and Power Quality 5.Recording 6.Scalability and.

Slides:



Advertisements
Similar presentations
CL100D series DSP controlled Uninterruptible power supplies.
Advertisements

Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
UR - The Universal Relay
VAMP 300 IED functionality Feeder relay Motor relay
1 GE Digital Energy Multilin Industrial Solutions for Energy Management and Energy Efficiency By John S. Levine, P.E. Levine Lectronics and Lectric, Inc.
Multi Functional Digital Fault Recorder
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
Protections from the technical point of view “What you always wanted to know about protections and were afraid to ask…” Petra Píclová Online training
FP5000 Refer to for the latest information on this constantly evolving productwww.eatonelectrical.com.
Application & Configuration
M Family Industrial Systems 1 M Family relays provide economical & reliable digital protection, metering, control and monitoring in an integrated package.
Industrial Systems Introducing the L90 Universal Relay Advanced transmission line protection and control High-speed current differential protection for.
MIG II DIGITAL FEEDER PROTECTION
The Peak in Performance
G GE Power Management 369 Motor Management Relay.
1 Industrial Systems A dvanced L ine P rotection S ystem.
Workflow Based Tools Simplifying All Job Functions.
G650 Generator Protection & Control System
Looking for a more powerful circuit monitor?
April 2011 ezPAC SA320/330. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.
Adaptive Protection of Distribution Feeders Alexander Apostolov, Benton Vandiver.
SFT 2841 IN CONNECTED MODE Prepare setting files.
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
Distribution Automation Overview, Activities, and Roadmap David G
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
TYPICAL SCADA SYSTEM FIELD UNIT SCADA H/W & S/W C TX O RX M E M Q N P
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
HighPROTEC-2 MRA4-2 Directional Feeder Relay Sales presentation
MiCOM P125 P126 & P127 27th, Aug 2007 Lakshmikanthan Balaji Application Engineer.
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
Advanced Datalogger: Z-GPRS3. # 4 Digital Input PNP, NPN bit max 30 Hz) RAM and Flash RAM 256 KB 1 MB + 8 MB (log) SD card max 32 GB.
DIGITAL MULTIMETER DMG
HighPROTEC-2 MRMV4-2 Motor protection relay with voltage measurement Sales presentation 2015/08/10.
ControlLogix Portfolio
VARLOGIC NRC12 Varmetric Controller
HighPROTEC-2 MRM4-2 Motor Protection Relay Sales presentation
PMC-680i web interface Sep.9th 2016.
C1300 advanced circular chart recorder
智能电力检测设备专业制造商和供应商 1 1.
IP-based 8-port Switched Power Manager
New EM210_AV.
HighPROTEC-2 MCDTV4-2 Transformer Protection with differential Sales presentation 2015/08/10.
HighPROTEC-2 MCA4-2 Directional Feeder Relay Sales presentation
PTS 3.3 C Portable Test System.
SCADA for Remote Industrial Plant
TPS - Thyristor Power Supply for Resistive/Inductive Loads
SMART GRID BASED FAULT IDENTIFICATION SYSTEM
FEEDER PROTECTION UNIT
Grid feeding monitoring relay
PowerFactory Monitor Dynamic System Monitor and Model Verification
ICP DAS Power Monitor and Management Solution 2016,03,28
Chapter 7 System Protection
Protection Philosophy
HighPROTEC-2 MRDT4-2 Transformer Protection with differential Sales presentation 2015/08/10.
PQube vs. X (instrument from competitors)
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
Interconnection of AES With The Grid
Data Acquisition (DAQ)
Integrated gateway-server
PowerLogic™ offer for the basic metering market
PowerLogic PM5350 High-performance multifunction power meter
energy revenue & power quality meter
PM9, PM9P and PM9C Power Meter
PowerLogic ION6200 Power and energy meter.
Simple, accurate tenant sub-metering
Power monitoring software
Presentation transcript:

Digital Multifunction Protection

INDEX 1.Key Features 2.Protection 3.Automation & Control 4.Metering and Power Quality 5.Recording 6.Scalability and Ergonomy 7.Applications 8.Models 9.Software

Key Features smART P500

Multifunctional Protection smART P500

Key Features I Configuration scalable from Simple to Complex Distribution Networks thanks to Configuration Wizard Assistant Sampling Rate of 128 Samples / cycle ensures a very High Measurement Accuracy (detection of up to 63 Harmonic possible) More than 18 Protection and Control Functions including Synchrocheck and 4 Step Recloser Unlimited Directional Sensitivity Thanks to choice of Polarizing Voltages depending upon Application Trip / Close signals to Breakers with Single or Three Phase Control Advanced Metering and Power Quality: Total Harmonic Distortion CBEMA Events Voltage Sags and Swells Load Profile Trending smART P500

Key Features II Sophisticated Oscillographic Records with User configurable Resolution (16, 32, 64 or 128 Samples / cycle), including Pre-fault Values and Fault Location 32 Fault Event Records 3500 Event records Reliability Indices reports for SAIFI, SAIDI, MAIFI, CAIFI, CAIDI and ASAI I /O Expandable up to 20 Programmable Inputs, 15 Programmable Outputs Programmable Front LEDs and Function Push Buttons including Manual Trip Close Push Buttons on the Front Local and remote Serial Communication Protocols: ArtCOM, MODBUS, DNP 3.0, Harris 5000, IEC & 104 smART P2P (16-Bit Peer to Peer) SMS ( Commands & Messages) and Web Server IEC Ready,… smART P500

Key Features III Automation Configuration Flexibility through 40 Programmable Graphical Logic Equation Blocks Easy Coordination with Legacy Over Current Protection, thanks to configurable Reset Time Delay Local / Remote Control Switch Configurable Language: Spanish, English, Portuguese, French Configurable Nominal Current: 1 or 5 A Configurable Nominal Frequency 50 or 60 Hz Automatic Reconfiguration Algorithms for Distribution Networks Innovative Solutions: Load Shedding, Simple Busbar Protection, Back-up Protection,,… Tested against all International Standards (Dielectric, Impulse, EMI, Transients, Fast Transients,…) smART P500

smART P500 Connecting Diagram

HW Blocks smART P500 Blocks diagram

HW 1 smART P500 Protective relay core consists of a DSP (CPU Digital Signal Processing). It performs Measurement and Protection algorithms as well as Data Storage and Communications. A FPGA supports the DSP, by controlling Analog Signal Acquisition, I/O ports, keyboard, display and LEDs, IRIG-B decoding and part of the basic algorithms for protection functions.

HW 2 smART P500 In addition to the protection core consisting of DSP-FPGA dual management, it also features the following items: FLASH Memory. It contains the O.S. (Firmware) of the protection, the settings, and historical stored data. Flash Memory keeps all data stored in it whether the relay is powered or not. It also permits the modification of its stored data. Therefore, OS can be updated without any HW change. SRAM Memory. It stores time variable information. A lithium battery avoids data loss, in case of shutdown or no power supply.

HW 2 smART P500 DRAM Memory. It stores dynamic data, not critical to protection relay operation. These data are loss in case of no Power Supply. QUART. A 4 x serial port control chipset. It allows the management of up to 4 serial ports simultaneously. Analog Input signals Acquisition system. Consisting of the analog inputs themselves, and a set of amplifying filters managing the signals prior to A/D conversion. After conversion, signals are translated into digital samples (128 samples/cycle) and processed by the DSP.

Protection smART P500

A sampling rate of 128 Samples per cycle (60 Hz Basis). leads to high measurement accuracy Open Phase: Settable 0,05 – 0,5 P.U. of I2 / I1 in steps of 0,01 P.U. Definite Time delay 0,05 – 300s in steps of 0,01s Current I

Current II Phase, Ground and Neutral over current and Load Unbalance (Negative Sequence) / sensitive Ground, Current Settings 0,1 – 20 X IN in steps of 1 mA Sensitive Ground: 50 mA nominal, settable 0,025 – 10A in Steps of 0,001 A Instantaneous or Definite Time up to 60s in steps of 0,01s Various Over Current – Time curves as per IEC / ANSI / US / BS / Individual: Standard Inverse, Very Inverse, Short Time Inverse, Long Time Inverse and special Very Inverse, Moderately Inverse Up to 4 user defined curves are possible Time dial multiplier and Reset time delay (if applicable) Definite time for Individual curves. settable up to 600s

A sampling rate of 128 Samples per cycle (60 Hz Basis) leads to high measurement accuracy Over and Under Voltage (Phase and Ground), Neutral Over Voltage 4 Steps Instantaneous or Definite Time up to 60s in steps of 0,01s Pick-up setting up to 300V in steps of 0,001V Voltage Unbalance: Negative sequence, 0,1 – 0,5 P:U. (V2 / V1 ) in steps of 0,01 P:U: Instantaneous or Definite time up to 60s in steps of 0,01s Voltage Transformer Fuse failure Voltage

Frequency A sampling rate of 128 Samples per Cycle (60 Hz Basis) leads to high measurement accuracy 4 Independent Steps are available Under- Over Frequency: Pick-up 46 – 65 Hz in steps of 0,01Hz Definite time 0,05 – 600s in steps of 0,01s Hysteresis up to 1 Hz in steps of 0,1 Hz (user configurable) Rate of Change of Frequency: Pick-up 0,2 – 5 Hz/s in steps of 0,05 Hz/s Pick-up delay cycles in steps of 1 cycle Operate time delay up to 2s in steps of 0,01s Supervisory Frequency 40 – 70 Hz

Directional A sampling rate of 128 Samples per Cycle (60 HZ Basis) leads to high measurement accuracy Phase and Ground / Sensitive Ground Over Current: Unlimited Directional Sensitivity for all asymmetrical faults thanks to choice of different Polarizing Voltages depending upon the application Forward / Backward / Bidirectional Maximum Torque Angle 0 – 900 in steps of 0,010 Operating time: as per settings of Over Current element Power: Active, Reactive and Apparent: Single and Three Phase, including Power Factor Operate time up to 60s in Steps of 0,01s Reactive Energy in 4 Quadrants Energy Accumulator In- / Outflow (independent)

Automation & Control smART P500

Synchrocheck A sampling rate of 128 Samples per Cycle (60 Hz Basis) leads to high measurement accuracy BUS / Line minimum Voltages up to 200V in steps of 0,1V BUS / Line Maximum Voltages up to 200V in Steps of 0,1V Voltage Supervision enables to choose one of different modes: Live line – Live Bus Dead BUS – Live line Live Bus – Dead Line Dead Bus – Dead Line Angle Difference: 0 – 900 in steps of 0,010 Frequency Difference: up to 5 Hz in Steps of 0,001 Hz Operating time: up to 100s in Steps of 0,01s

Recloser Up to 4 Reclosing cycles can be selected or Recloser blocked Reclose Time: 0,1 – 600s in Steps of 0,01s Reset Time after Autoreclose / Manual Close: up to 600s in Steps of 1s (independently selectable) Current – Time Trip curves / Constant time Trip after each Reclose are independently selectable High Current Lock-out: Pick-up: 0,1 – 20 X IN Constant Time: up to 60s in Steps 0f 0,01s can be applied to each Reclose or by line pick-up independently

Other Functions Breaker Failure: Pick-up: 0,2 – 2 X IN Operate Time: up to 60s in Steps of 0,01s Cold load Pick-up: Cold load Time: up to 10000s in Steps of 1s Operate Time: up to 3600s in Steps of 0,01s Load Profile (trending) Remote / Local Control Switches

11 Digital Outputs expandable up to 15 without Firmware upgrade Trip outputs to operate Breakers with single or Three Phase control Programmable 11 Optoisolated Digital Inputs expandable up to 20 without Firmware upgrade Programmable 40 Programmable Logic Equation Blocks Trip / Close Pushbuttons 5 Programmable Buttons with LEDs Hot Line Tag Outputs & Inputs

4 Ports to Support Local and Serial Communication: 2 X RS X RS 485 Ethernet / USB / Bluetooth (Optional) IRIG-B for Time Synchronization Supported Protocols: BECO 7000, HARRIS 5000 MODBUS RTU, DNP 3.0 IEC & 104 smART P2P 16 Bit TCP / IP with Ethernet / Bluetooth Communication I

Communication II Local / remote Access through these Ports enable to download the settings, upload the information stored in the relay (Records of Metering, Demand, Events and Oscillographic Fault Records as well as preliminary diagnostics Communication assisted Trip / Close operations possible IEC Ready Remote status via SMS Remote Control via ProART

Metering and Power Quality smART P500

Metering In addition to the Sampling Rate of 128 S / Cycle Measures such as Calibration at different Current Magnitudes enable to reach a Precision of Class 0,2% in Measurements (excluding the accuracy class of the customer CT core). Instantaneous RMS Values of Current (Phases, Ground and Sensitive Ground) Phase and Line Voltages (RMS) Sequence Currents and Voltages Active, Reactive and Apparent Power in all the 4 Quadrants including Power Factor (Single / 3 Phase) Active and Reactive Energy (Bi-directional) Rolling Maximum Demand of Currents, Voltages, Active and Reactive Power (Bi- directional) including Power Factor (calculated for Single or Three Phase) with User Configurable Integration Interval Sequence Components of Current and Voltage Signals Equipment Temperature Thermal Demand

Metering

Load Profile - Trending Up to 25 Parameters can be selected to be stored Instantaneous, Maximum and Minimum Demands per Phase and Three Phase Currents, Voltages Active, reactive and Apparent Power including Power Factor Average Interval up to 60 min in Steps of 1 min. Up to 3000 Values can be stored

Power Quality Total Harmonic Distortion (THD), Crest Factor (CF), Distortion Factor (DF) of Current and Voltages for each Phase PQ Events: Voltage-Sags, -Swells, Voltage and Current imbalances, Phase and Supply Voltage loss, Short and long Voltage Variations, Frequency Variations CBEMA Parameters Reliability Indices: System Average Interruption Frequency SAIFI) System Average Interruption Duration Index (SAIDI) Momentary Average Interruption Frequency Index (MAIFI) Customer Average Interruption Frequency Index (CAIFI) Customer Average Interruption Duration Index (CAIDI) Average Service Availability Index (ASAI)

Power Quality

Recording smART P500

Event Records I For the last 32 Faults: Pick-up, Trip, Reclose, Lock-out, and Fault Duration Pre-fault Values of Voltage and Current for each Phase, Neutral and Sensitive Ground Activated Protection Elements Reason for Trip Fault Direction Active Settings Group

Event Records II Sequence of Events Changes in Protection Configuration States of Digital Inputs and Outputs Automated Functions, Statistical Data related to the operation and Supervision of the Equipment Metering Accuracy Signals from Supervision Elements, etc Each Event contains its corresponding RMS Values of Current and Voltage A Total of 3500 Events can be stored. The customer can configure the Events to be Recorded.

Fault Record

Oscillographic Records Current and Voltage Waveforms up to 3000 Cycles for Faults and for User selected Events can be stored Customer can choose: The Number of Samples / Cycle (16, 32, 64 or 128) The Number of Cycles of Pre-Fault Values (up to 20) Total Number of Cycles per Record Total Number of Records that can be stored depends upon the choice of the above Parameters For each Fault Record, the Fault Location is also calculated Harmonic Analysis

Oscillography II

SOE- Sequence of Events

Reliability - Monitoring and Self Diagnostics Auxiliary Voltage Supply Breaker Control Circuits (Close / Trip) Voltage Transformer Secondary Circuits (Fuse Failure) Breaker Wear Phase Sequence Continuous Monitoring Internal (Continuous Monitoring) Voltages Hardware (A/D-Converters, Flash SDRAM, SRAM,…) Inputs and Outputs Display Keyboard

Scalability and Ergonomy smART P500

Configuration I Configuration Wizard allows the User to select only those Functions and Features required for his application. All the other Functions will be masked out providing Flexibility of Configuration Simplicity of choosing the Settings Ease of Navigation Configurable Settings include: Protection, Control and Measurement Functions LEDs and Front Programmable Keys Communication Parameters for Serial Ports and Communication Profile

Configuration II The Programmable logic Blocks can be configured easily to design the Automation and Operation needs Waveform Records IRIG-B Time Synchronization,… etc Up to 6 Setting Groups can be configured enabling Easy Adaptation to changing Service Conditions and to the future operating requirements of Smart Grids The Settings can be uploaded to the Equipment either locally or using Remote Communication Thanks to the programmable Reset Time delay of the Current Elements, Easy Coordination with Legacy Equipment is possible.

Using the Keyboard in the Front Panel the stored Values: Relay Parameters Event reports Other records Relay Status,… etc Can be checked on the Display above the Keyboard Ergonomy

Applications smART P500

Applications Reconfiguration of a Distribution Network (Ring) Reconfiguration of Loads in a Distribution Substation Using Load Profiles, Frequency and Voltage Simple Busbar Protection Using Directional Comparison (Incoming Vs Outgoing) Load Shedding Simple Busbar Protection Directional comparison allows better coordination and selectivity Upstream and feeder blocking schemes

Applications

Models smART P500

Models ApplicationModel Recloser ControlsmART P500 RC Feeder Management RelaysmART P500 AL Cap Banks ProtectionsmART P500 BC

Software Software proART

Monitor and configuration SW

Real Time Monitor