Monitoring the Concentration of Fluoride and Other Impurities Across a Purification System Naomi Mburu University of Maryland, Baltimore County Supervisors:

Slides:



Advertisements
Similar presentations
Gas Chromatography.
Advertisements

Cruces-Blanco, C., Gamiz-Gracia, L., Garcia-Campana A.M., Applications of Capillary Electrophoresis in Forensic Analytical Chemistry Trends in Analytical.
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
Fundamentals of Method 23 What You Always Wanted to Know About EMPC but were Afraid to Ask Office of Air Quality Planning and Standards Air Quality Assessment.
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
Gas chromatography–mass spectrometry (GC-MS) is an analytical method that combines the features of gas-liquid chromatographyand mass spectrometry to identify.
Mass Spectrometry Courtesy Purpose of Mass Spectrometry  Produces spectra of masses from the molecules in a sample of material, and.
Measurements in Fluid Mechanics 058:180 (ME:5180) Time & Location: 2:30P - 3:20P MWF 3315 SC Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor: Lichuan.
The RPC Closed loop Gas System. Schedule for completion - update Status Supplier: ok Mixer: ok Humidifier: ok Purifiers: installed, but not completely.
1 April 7, 2009 C. Lu Monitoring the RPC Gas Mixture with a Gas Chromatograph C. Lu Princeton University.
Plans for the Muon Gas and Cooling Systems LHCb infrastructure workshop February Burkhard Schmidt, with important input from Roberto Guida and Beatrice.
Gas Chromatography And Mass Spectrometry
Gas Liquid Chromatography
Analytical Chemistry Option A Part 1: Mass Spectrometry & H-NMR.
02/07/2014R. Guida CERN/PH-DT-DI1 RPC R&D Collaboration PH-DT Topics of Interest Studies of gas systems performance and development of dedicated gas modules.
GCMS: gas chromatography and mass spectrometry
The Resistive Plate Chamber detectors at the Large Hadron Collider experiments Roberto Guida Paolo Vitulo PH-DT-DI Univ. Pavia CERN EDIT school 2011.
An Introduction to Chromatography What is chromatography? The separation of a mixture by distribution of its components between a mobile and stationary.
Summer Updates- Summer Student Report Emine Altuntas Stephen Fee Supervisors: Mar Capeans, Ivan Glushkov, Roberto Guida Gamma Irradiation Facility.
Optimization of the operation of Muon systems at LHC: a closed- loop gas system for RPCs and a CF 4 -recuperation unit for the CSC of CMS Conseil Européen.
1 A.Di Ciaccio LHC upgrade Working Group November 2005 The ATLAS RPC trigger system  The entire stand-alone muon system has been designed to handle background.
Optimization of the Resistive Plate Chamber operation with a closed loop gas system at the Large Hadron Collider experiments M. Capeans, I. Glushkov, R.
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
Detection of trace elements in meteorites using PIXE Presented by: Sasha dos-Santos.
Measurements in Fluid Mechanics 058:180:001 (ME:5180:0001) Time & Location: 2:30P - 3:20P MWF 218 MLH Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor:
Study of UV absorption and photoelectron emission in RPC (Resistive Plate Counters) detector with an UV source Carlo Gustavino (INFN-LNGS) RPC and their.
The RPC Closed loop Gas System Slides from Bianco and Guida.
Gas Systems for Particle Detectors R.Guida on behalf of the PH-DT-DI/Gas Service Team PH-DT Seminar CERN September 4 th, 2014.
Operation, Modeling and Analysis of the Reverse Water Gas Shift Process Jonathan Whitlow Florida Institute of Technology NASA/ASEE Summer Faculty Program.
Andrea Di Simone Andrea Di Simone – INFN Roma2 Andrea Di Simone CERN PH/ATC and INFN-CNAF On behalf of ATLAS RPC groups: Lecce, Napoli, Protvino, Roma2.
Neutrinos are tiny, neutral, elementary particles which interact with matter via the “weak force”. The Sun produces over two hundred trillion trillion.
GIF++ gas systems 11/07/2014Ernesto, Roberto PH-DT-DI gas service1.
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
STATUS REPORT WP7 Facilities and Component Analysis for Detector R&D Activities and Status Resources and Expenditures Work plan Mar CAPEANS 3/11/08 M.C.
HPLC.
Applications as Residual Gas Analyzer (RGA)
NSS2006Shengli Huang1 The Time of Flight Detector Upgrade at PHENIX Shengli Huang PHENIX Collaboration Outlines: 1.Physics motivations 2.Multi-gap Resistive.
CHROMATOGRAPHY Chromatography is used to separate and analyse small amounts of mixtures Methods involve a stationary phase and a mobile phase. There are.
SIMULATION STUDIES ON THE EFFECT OF SF 6 IN THE RPC GAS MIXTURE Mohammed Salim, Aligarh Muslim University, INDIA Presented by Satyanarayana Bheesette,
2008 SPECIFICATIONS HPLC and GAS CHROMATOGRAPHY A guide for A level students KNOCKHARDY PUBLISHING.
Operation, performance and upgrade of the CMS Resistive Plate Chamber system at LHC Marcello Abbrescia Physics Department - University of Bari & INFN,
Chemical Ideas 7.6 Chromatography.
A guide for A level students KNOCKHARDY PUBLISHING
Review of Basic Atomic Structure, Mass Spectrometry
CMS Galaxy varian CP-4900 GC Gas Analysis
R. Guida PH-DT-DI Boston Students Program CERN, 16/1/2013
Mass Spectrometry Courtesy
India-based Neutrino Observatory (INO)
ROSINA, COSAC & PTOLEMY Reviewer: Heather Franz 2/15/16 – 2/17/16
A guide for A level students KNOCKHARDY PUBLISHING
Mass Spectrometry Courtesy
Mass Spectroscopy (MS) Applications as Residual Gas Analyzer (RGA)
Mass Spectrometry.
HPLC.
GC 1 – C6+ Analysis or C9+ Analysis (Train 1: C6+)
Pure Carrier Gas Grades (subjective)
Project Presentations August 5th, 2004
Mass Spectrometry Courtesy
Residual Gas Analyzer (RGA)
Chemistry The study of: the composition (make-up) of matter
What is Chromatography?
How to quantify substances in a mixture using gas chromatography
32A-4 Chromatographic Detectors
A guide for A level students KNOCKHARDY PUBLISHING
GAS CHROMATOGRAPHY.
Electron Capture Detectors
CHROMATOGRAPHY.
Mass spectrometry (MS) is an analytical technique that can be used to determine the mass, elemental composition or chemical structure of molecules. Mass.
Suppose we make a new compound containing of C,H, and N
Presentation transcript:

Monitoring the Concentration of Fluoride and Other Impurities Across a Purification System Naomi Mburu University of Maryland, Baltimore County Supervisors: Beatrice Mandelli and Roberto Guida R&D for LHC Experiments

Background ●Gas mixtures must be recycled because they are expensive and may produce greenhouse effects ●Typical gas composition for RPC detectors: ○94.7% Freon (C ₂ H ₂ F ₄ ) to induce avalanche ionization ○5.0% Isobutane (i-C ₄ H ₁₀ ) for quenching ○0.3% Sulfur Hexafluoride (SF ₆ ) as a source of electronegativity Schematic of gas recirculation system at CMS Cross-section illustration of the components of the CMS detector ●Resistive Plate Chambers(RPCs) are a type of muon detector that utilizes gas mixtures to induce avalanche ionization reactions ●Harmful impurities can damage the inside of the detector if they are not properly filtered 2 Naomi Mburu, CERN Summer Student 2016

How do we monitor purification systems? ISE Fluorine Monitor Ion Selective Electrodes (ISE) Gas Chromatography (GC)/ Mass Spectrophotometry (MS) MS identifies components by ionizing and accelerating the sample in a magnetic field. Mass/charge ratios are then determined. Coupled together to allow for separation, quantification and identification of gas components Measures potential difference between sample and a standard, then utilizes Nernst Equation to solve for ion concentration Used to determine the accumulation of Fluoride ions over time before and after purifier Schematic of the GC internal set-up 3 Naomi Mburu, CERN Summer Student 2016 GC separates gas components in time and quantifies them using chemically treated columns and a thermal conductivity detector (TCD)

ISE Set-Up Ideal Slope: 56+/-4 Step 1: Calibrate Electrodes Step 2: TroubleshootingStep 3: Stability Tests Image from Hannainst.com Inner Stem Crystal Goal: Monitor the levels of Fluoride build-up over time before and after the purifier 4 Naomi Mburu, CERN Summer Student 2016

Installing ISE Station The ISE station is now installed and recording Fluoride concentration data ISE installed at gas distribution racks Electrode Sample gas bubbler 5 Naomi Mburu, CERN Summer Student 2016

GC/MS Set Up Goals: 1.Troubleshoot Systems and couple GC with MS 2.Set up remote valve control 3.Identify new gas impurities before and after the purifier Schematic of valve controller set-up Micro gas chromatography machine Chromatograph Image from Galaxie Manual 6 Naomi Mburu, CERN Summer Student 2016 Signal (μV) Time (Sec)

GC/MS Analysis Propane Difluoromethane Experimental Peak Reference Peak Experimental Peak Reference Peak GC/MS chromatograph 7 Naomi Mburu, CERN Summer Student 2016 Sulfur Hexafluoride Freon Isobutane

Conclusion Gas mixture analysis is used to prevent aging of detector ISE, GC, and MS can used to determine the amount, identity, and accumulation of gas system components. 8 Naomi Mburu, CERN Summer Student 2016 Acknowledgements I would like to thank the NSF for funding my summer at CERN I would also like to thank my supervisors, Beatrice Mandelli and Roberto Guida