Preventative Maintenance For Water Treatment Systems Presented by:

Slides:



Advertisements
Similar presentations
Maintenance Shows of America April 2010 Tampa Florida Presented By: Byron Nichols Representing: The American Society of Power Engineers.
Advertisements

Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank.
Responder FW-60 Operation of the FW-60 Unit. Components 2 Solar Panel Spare Filters Power Supply Spare UV and Quartz Sleeve 12 Volt Pig-tail Hoses Strainer.
 Without reference, identify principles relating to Fixed Radiological X-RAY PM with at least 70 percent accuracy.
HVAC523 Soldering.
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
The pumps should be tightened about once a month. If a new pump is installed, the pump should be initially tightened and then re-torqued one week later.
Cooling Tower Maintenance Training.
FoamPro 1600 Series Fully automatic Class A foam ONLY
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
HVACR312 - Refrigeration Metering Devices.
Introduction Leak Detection Sam Godfrey SAMCO Leak Detection Services 1308 Daytona Dr. Austin, TX
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Queries Are soap and drying facilities compulsory in toilet areas? Are soap and drying facilities compulsory in food handling areas? Should we stop recommending.
Diesel Generator Reliability: Lessons Learned from Storms
Pump Installation Vigyan Ashram, Pabal.
Experts in Chem-Feed and Water Treatment General Hydraulics Fluid Mechanics.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Lease Automatic Custody Transfer
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
CHAPTER 4 CPB 20004: Plant Utility n Maintenance
How to make “Touch Free” washing clean better. RYKO Manufacturing Company.
Gasoline fuel supply systems Function: store, transport, Pressurize and filter gasoline going to carburetor or fuel injection system.
David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.
ProMinent Fluid Controls, Inc.
1-1-Why Maintenance HVAC ? Increases equipment life & reliability Reduces size & scale & number of repairs Lowers maintenance costs through better.
CHILLED WATER AIR-CONDITIONING SYSTEMS
CHEMICAL HANDLING Standard Operating Procedures and Personal Protective Equipment For REACT-OX® Program Applications.
Free Residual Chlorine Measurement
Staying in Compliance Dispensing Equipment Spill/Overfill Presented by Travis Benton United Pump and Controls, Inc.
Automating Your Water Treatment Program Presented by:
Discover the Dosmatic Difference Trouble Shooting your Dosmatic injector for years of service.
Discover the Dosmatic Difference Maintaining your Dosmatic injector for years of service.
Welcome Growers Discover the Dosmatic Difference Installing your Dosmatic injector for years of service.
The C.I. Engines Fuel System  The C.I. engine demands that the fuel supplied is –  Timed to inject when the piston is near the end of the compression.
James McIntyre VRF Training Manager V5 Key Components.
CENTIFUGAL PUMP OPERATION
Temperature Test Allows monitoring of temperature changes.
Understanding the system.
BioTector COD TOC TN analyzer
The BioTector B7000i TOC analyzer with integrated oxygen concentrator
Mould Maintenance Presented By S.K Mandal.
Quick Start Guide for Flex Flow Pump
RAINMAKER and RAINMAKER Enviro
AIRCRAFT PNEUMATIC SYSTEMS
Optimum Pump Performance for Process Applications
Tractor Safety, Operation, and Maintenance
14 Refrigerant Recovery, Recycling, and Recharging.
Objectives : ANALYZE home maintenance techniques
INDUSTRIAL HYDRAULICS
Fault detection Lecture (1).
Risk Assessment should include:
Parul Institute of Technology
Tractor Safety, Operation, and Maintenance
Sprayers Ride-On-Sprayers Tank Sprayers
In order to design a sprinkler or drip irrigation system for the lawn, we must first know how much flow is available in gallons per minute from the water.
How can you Maintain an Acrylic Sports Surface
How to: Walchem W600 Calibration Introduction Calibration Overview
Trouble Shooting The following section is to assist you in the trouble shooting process of your deicer. Although we do not expect to have problems with.
The BioTector B3500ul TOC analyzer Process Tests
Troubleshooting 11/14/2018 Water King Service Seminar.
How to: Walchem W600 Calibration Introduction Calibration Overview
“Lesson – Installing Material Cartridge and Printing a File”
Overview Menus & Settings
COOLING WATER TREATMENT CONTROLLER
Boiler Room LOG Sheets: Interpreting the Records
Machine Shop safety.
Chapter 7: Classroom and shop manuals
Presentation transcript:

Preventative Maintenance For Water Treatment Systems Presented by:

Preventative Maintenance PM will: Prolong the life of equipment Provide more efficiently operating systems Minimize emergency maintenance calls Save money in the long run

Water Treatment Systems Water treatment controllers Chemical metering pumps Bleed-off valve assemblies

Water Treatment Controllers Probe Maintenance Conductivity Probes Without accurately controlling TDS levels, chemical treatment efforts are of little use Inaccurate conductivity readings are caused by fouled/failed probes

Conductivity Probe Maintenance Clean probe vs. fouled probe Some fouling only appears when the probe is dry...

Conductivity Probe Maintenance Loose coatings or oils - soft cloth with detergent Hard coatings or scale –mild acid (5% HCl) –fine-grit sandpaper or emery cloth

Conductivity Probe Maintenance Always clean probe before calibration > 5-10% error is excessive Cleaning/calibration frequency depends on water quality (monthly is a good starting point) Compare controller’s reading to calibrated hand tester (easiest) or check against buffer solutions

Conductivity Probe Maintenance Storage - wet or dry (drain sample line in winter to protect plastic piping from bursting) Life span - several years when properly maintained

pH/ORP Probe Maintenance pH/ORP Probes pH probes are required for automated acid feed programs ORP probes are often used for automated oxidizing biocide feed Probe anatomies are similar (reference junction & measurement surface)

pH/ORP Probe Maintenance Reference junction should be white Soft coatings - vigorous stirring in water, squirt bottle, or gentle soft cloth Hard coatings - mild acid (5% HCl) Oils - Spray detergent (409)

pH/ORP Probe Maintenance pH probes should be cleaned & calibrated as needed (compare accuracy against a hand tester or standard solutions); weekly is a good starting point Use periodic 2-point pH calibrations (low and high buffer solutions) to ensure accurate span ORP is normally not calibrated (reads in a range, not a single point); clean probe if ORP doesn’t maintain the target Cl- or Br- residuals

pH/ORP Probe Maintenance Flat surface probes are self- cleaning to some degree (no dead spots) Flat surface probes resist breakage (no protruding bulb)

pH/ORP Probe Maintenance pH/ORP probes last 6-24 months depending on quality of water; replace annually (or every other year at the longest) New ORP probes take several hours to initialize and then respond within minutes New pH probes are ready out of the box and respond in a matter of seconds Reaction time and span accuracy decrease with age/fouling

pH/ORP Probe Maintenance Disconnect pH/ORP probes when the controller is unpowered (they are a type of battery that will drain) pH/ORP probes cannot be stored dry –4.0 buffer for pH probes (never DI water) –tap water for ORP probes Reviving a dried probe may be possible by soaking the probe in its storage solution for 8+ hours (save the shipping cap/bottle for storage)

Flow switches prevent relay activation when the recirc pumps are off Fouled flow switches lead to improper relay activation Flow Switch Maintenance

Thermal flow switches with no moving parts minimize debris hang-ups Still susceptible to scaling over Flow Switch Maintenance

Metering Pump Maintenance Pump maintenance is limited primarily to the liquid end. A pump liquid end will last a few years under normal conditions. Life span is affected by: Chemical compatibility Frequency of use Temperature

Metering Pump Maintenance A typical pump liquid end consists of over 60 individual components arranged into major sub- assemblies. Replacing assemblies vs. components: –Less time consuming –More cost effective

Metering Pump Maintenance Foot valve assembly Foot valves feature an integral strainer screen and cartridge check valve. Clean or replace when pump will not prime or when pump continually loses prime. Install 1”-2” above bottom of tank to minimize blockages.

Metering Pump Maintenance Head assembly Consists of head, suction & discharge valves, priming valve, diaphragm, & screws Clean or replace when pump will not move chemical or when chronic leakage occurs. Do not use Teflon tape on pump head fittings. Tighten fittings only hand-tight.

Metering Pump Maintenance Injection valve assembly Injection valves feature a spring-loaded cartridge check valve. Clean or replace when chemical won’t pass or when tower water overcomes check valve. Inspect nozzle tip for chemical crystallization and blockages.

Metering Pump Maintenance General tips: Replace all wear & tear components at the same time (will save on multiple repair attempts). Keep a spare liquid end on hand to prevent unnecessary downtime in chemical treatment program. Inspect tubing annually for cracks and splits. Replace as needed.

Bleed Valve Assemblies Use a strainer with solenoid valves; clean as needed Consider upgrading to a motorized ball valve if plugged valves are a recurring problem.

Any Questions?