{ Digital Image Processing By Professor Stelmark.

Slides:



Advertisements
Similar presentations
Patient information extraction in digitized X-ray imagery Hsien-Huang P. Wu Department of Electrical Engineering, National Yunlin University of Science.
Advertisements

DIGITAL RADIOGRAPHY.
The Field of Digital Radiography
Copyright © 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins CHAPTER 15 Creating the Digital Image.
Primary Exposure Factors IV
1 DIGITAL RADIOGRAPHY. 2 Digital Radiography A “filmless” imaging system introduced in 1987 Digital radiography uses an electronic sensor, instead of.
Dr. Mustafa Zuhair Mahmoud Mr.Ali B Alhailiy بسم الله الرحمن الرحيم 1.
Chapter 7 Digital Radiographic Image Processing and Manipulation
Digital Image Manipulation I By Professor Stelmark.
QC/PACS Artifact Identification. Artifact Causes Image receptor/Hardware –Dirty –Foreign material –Failures Software –Algorithm –Enhancements/manipulations.
FILM ARTIFACTS.
Optical Density and Brightness
Chapter 5 Cassette-Based Image Acquisition
Digital Radiography Chapter 22. History of Digital Radiography Slower process of conversion because no pressing need to convert to digital radiography.
CR Image Acquisition By Professor Stelmark.
ARRT & Other DIGITAL Terms Defined Supplement to HW assignment
Digital Image Characteristic
Tutorial 2: Working with Image Files. Objectives Session 2.1 Learn about file formats and their uses Change file type, file size, and resolution Examine.
Fundamentals of Digital Radiology
Computers in Imaging Q & A Robert Metzger, Ph.D..
Elsevier items and derived items © 2008 by Mosby, Inc., an affiliate of Elsevier Inc.1 Digital Radiographic Image Processing and Manipulation.
Color Correct and Remove Keystoning A minimalist approach to photographing your art By Paul Marley.
Lecture 5. Morphological Image Processing. 10/6/20152 Introduction ► ► Morphology: a branch of biology that deals with the form and structure of animals.
The Digital Image Dr. John Ryan.
Seeram Chapter #3: Digital Imaging
Factors affecting CT image RAD
Computed Radiography (CR), & Digital Radiography (DR) Images
Computed Radiography By Prof. Stelmark. Presently, an acceleration in the conversion from screen-film radiography (analog) to digital radiography (DR)
 The image that the digital camera sensor captures is based on the light reflected or emitted from a subject and how much the sensor is exposed to that.
Things they never tell you when the equipment is installed REV 11/2008
Radiographic Quality Visibility and Sharpness
Digital Image Processing Lecture 16: Segmentation: Detection of Discontinuities Prof. Charlene Tsai.
More digital reading explaining LUT RT 244 Perry Sprawls, Ph.D. Professor Emeritus Department of Radiology Emory University School of.
Digital Image Processing Lecture 16: Segmentation: Detection of Discontinuities May 2, 2005 Prof. Charlene Tsai.
More digital 244 wk 12 Perry Sprawls, Ph.D. Professor Emeritus Department of Radiology Emory University School of Medicine Atlanta, GA,
CR Image Acquisition By Professor Stelmark.
Digital Radiographic Image Processing and Manipulation Chapter 7.
Answer (slide 1/3): The correct answer is b) Black Surround Mask applied incorrectly. Black Surround Masking is an image processing feature used to reduce.
By Prof. Stelmark. Digital Imaging In digital imaging, the latent image is stored as digital data and must be processed by the computer for viewing on.
Photoshop Review What we need to know. Image>Image size A panel in Photoshop where you can see the size and resolution of your image.
BIO 498: Additional Photoshop Techniques Image Manipulation.
Chapter 10 Digital Signal and Image Processing
Computed Tomography Image Manipulation
Fundamentals of Digital Radiology
Lesson 5: Viewing and Printing Workbooks
Computed Tomography Basics
Getting Started with Adobe Photoshop CS6
Chapter 5 Cassette-Based Image Acquisition
Digital Image Processing Lecture 16: Segmentation: Detection of Discontinuities Prof. Charlene Tsai.
Rad Tech 265.
Digital image self-adaptive acquisition in medical x-ray imaging
Template for IBI poster 56 inches in width and 36 inches in height The title occupies no more than two lines First Author1, Second Author2, Third Author1,2.
Quality Control Testing of Screen Speed
Tuesday Physics Case of the Day
מה צריך רנטגנאי לדעת על דימות דיגיטלית?
Challenges with Digital Imaging
Fundamentals of Digital Radiology
CS Digital Image Processing Lecture 5
Resident Physics Lectures
Digital Imaging CHAPTERS 1, 4-7 CARTER.
Template for IBI poster 36 inches in width and 48 inches in height The title occupies no more than three lines First Author1, Second Author2, Third Author1,2.
Chapter V, Printing Digital Images: Lesson III Using Software to Adjust the Image
Template for IBI poster 48 inches in width and 36 inches in height The title occupies no more than two lines First Author1, Second Author2, Third Author1,2.
VISUAL COMMUNICATION USING ADOBE PHOTOSHOP CREATIVE SUITE 5
INSTRUCTIONAL NOTES There are many similarities between Photoshop and Illustrator. We have attempted to place tools and commands in the context of where.
Digital Radiographic Image Processing and Manipulation
How to take better pictures with your digital camera
Digital radiography.
Presentation transcript:

{ Digital Image Processing By Professor Stelmark

Postprocessing Postprocessing functions are computer software operations available to the radiographer and radiologist that allow manual manipulation of the displayed image. These functions allow the operator to adjust manually many presentation features of the image to enhance the diagnostic value.

Background Removal or Shuttering Anytime a radiographic image is viewed, whether it is film/screen or digital, unexposed borders around the collimation edges allow excess light to enter the eye. Known as veil glare, this excess light causes oversensitization of a chemical within the eye called rhodopsin that results in temporary white light blindness. Although the eye recovers quickly enough so that the viewer recognizes only that the light is very bright, it is a great distraction that interferes with image reception by the eye. In film/screen radiography, black cardboard glare masks or special automatic collimation view boxes were sometimes used to lessen the effects of veil glare, but no technique has ever been entirely successful or convenient. In CR, automatic shuttering is used to blacken out the white collimation borders, effectively eliminating veil glare. Shuttering is a viewing technique only and should never be used to mask poor collimation practices.

Electronic collimation has no effect on overall image quality or patient exposure.

Image Orientation Image orientation refers to the way anatomy is oriented on the imaging plate. The image reader has to be informed of the location of the patient’s head versus feet and right side versus left side. The image reader scans and reads the image from the leading edge of the imaging plate to the opposite end. The image is displayed exactly as it was read unless the reader is informed differently. Vendors mark the cassettes in different ways to help technologists orient the cassette in such a way that the image will be processed to display as expected. Fuji uses a tape-type orientation marker on the top and right side of the cassette. Kodak uses a sticker reminiscent of the film/screen cassette identification blocker. Some examinations, however, require unusual orientation of the cassette. In these cases, the reader must be informed of the orientation of the anatomy with respect to the reader. In DR, for which no cassette is used, the position of the part should correspond with the marked top and sides of the imaging plate.

Image Stitching When anatomy or area of interest is too large to fit on one cassette, multiple images can be “stitched” together using specialized software programs. This process is called image stitching. In some cases special cassette holders are used and positioned vertically, corresponding to foot-to-hip or entire spine studies. Images are processed in computer programs that nearly seamlessly join the anatomy for display as one single image. This technique eliminates the need for large (36-inch) cassettes previously used in film/screen radiography.

Image Annotation Many times, information other than standard identification must be added to the image. In screen/film radiography, time and date stickers, grease pencils, or permanent markers were used to indicate technical factors, time sequences, technologist identification, or position. The image annotation function allows selection of preset terms and/or manual text input and can be particularly useful when such additional information is necessary. (Function availability depends on the manufacturer.) The annotations overlay the image as bitmap images. Depending on how each system is set up, annotations may not transfer to PACS. Again, input of annotation for identification of the patient’s left or right side should never be used as a substitute for technologist’s anatomy markers.

Another common measurement a radiologist may use is a region of interest (ROI). It will determine the pixel intensity of a certain area. Because each type of tissue or fluid has a little bit different intensity reading, the radiologist can make a determination whether something is solid or fluid.

Magnification Two basic types of magnification techniques come standard with digital systems. One technique functions as a magnifying glass in the sense that a box placed over a small segment of anatomy on the main image shows a magnified version of the underlying anatomy. Both the size of the magnified area and the amount of magnification can be made larger or smaller. The other technique is a “zoom” technique that allows magnification of the entire image. The image can be enlarged enough so that only parts of it are visible on the screen, but the parts not visible can be reached through mouse navigation

Subtraction is a technique that can remove superimposed structures so that the anatomic area of interest is more visible. Because the image is in a digital format, the computer can subtract selected brightness values to create an image without superimposed structures

Black/white reversal is a postprocessing technique that reverses the grayscale from the original radiograph.

Edge enhancement is a postprocessing technique that improves the visibility of small, high-contrast structures. Image noise may be slightly increased, however.

Smoothing is a postprocessing technique that suppresses image noise (quantum noise). Spatial resolution is degraded, however.

3D Angiography A three-dimensional (3D) image may be produced from the image data acquired during a rotational acquisition. These data are processed by a sophisticated computer system with the use of digital reconstruction techniques similar to those used in computed tomography.