Reading assignment: section 26E(p781) Chapter 26 # 2, 3, 14, 15, 16 Chapter 27 # 7(a,d,f), 22, 23, 24, 25.

Slides:



Advertisements
Similar presentations
Gas Chromatography Introduction 1.) Gas Chromatography
Advertisements

GAS CHROMATOGRAPHY CHAPTER 21.
Gas Chromatography Lecture 36.
Gas Chromatography Vaporization of sample Gas-solid
Gas Chromatography 427 PHC.
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
GAS CHROMATOGRAPHY.
Lab Methods Day June 25, 2014 Gas Chromatography
Mobile phase is a gas! Stationary phase could be anything but a gas
Gas Chromatography A.) Introduction: B.) Equipment:
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
Experiment 6 Simple and Fractional Distillation.
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
1 Gas Chromatography Lecture a. Thermal Conductivity Detector (TCD) This is a nondestructive detector which is used for the separation and collection.
The geometry of capillary columns is fairly simple, consisting of length, internal diameter, and stationary phase thickness. Nevertheless, there are endless.
Gas Chromatography.
Gas Chromatography.
Chapter 27 Gas Chromatography
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Capillary Columns Nicholas H. Snow Department of Chemistry, Seton Hall University, 400 South Orange Avenue, South Orange, NJ 07079
Gas Chromatography. Mobile phase: Inert gas such as N2 or He. Mobile phase: Inert gas such as N2 or He. Stationary phase: May be solid (GSC) or Stationary.
Gas Chromatography.
Chromatography Chapter 4.
GC Detectors Ideal Detector Characteristics: 1. Universal Response
Gas Liquid Chromatography
Gas Chromatography. Gas Chromatography Basics Gas Liquid Chromatography (GLC) Gas Solid Chromatography (GSC) Mobile phase does not interact with analyte.
Chapter 22 GC & LC Gas Chromatography -1 1.Schematic diagram.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Effect of Packing Particle Size on Plate Height. Resolution between 2 adjacent peaks.
GAS – LIQUID CHROMATOGRAPHY BY M. GLORY HEPSIBAH M.PHARM (PH. ANALYSIS) BHARAT COLLEGE OF PHARMACY.
Gas Chromatography A.) Introduction: B.) Equipment:
Chapter 27 Gas Chromatography 1. Principles
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
PLOT Columns P orous L ayer O pen T ubular Porous layer open tubular (PLOT) columns are defined as capillary columns where the inner surface is coated.
animation.php.
High Performance Liquid Chromatography Instrumentation.
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Gas Chromatography Lecture 38.
Gas Chromatography Experiment. Gas Chromatography - Gas Chromatography (GC) is a common technique used to separate and identify volatile organic compounds.
Intensive General Chemistry Chemical separations II Isabelle Vu Trieu
Analytical Separations
Basic Gas Chromatography. History Separation of dyes by Runge Separation of plant pigments by Tswett Theoretical gc (Martin & Synge)
Created with MindGenius Business 2005® Gas Chromatography Gas Chromatography From Harris, Quantitative Chemical Analysis, 6e, Chapter 24.
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
GAS CHROMATOGRAPHY In gas chromatography (GC), the sample is injected onto the head of a chromatographic column and immediately vaporized. The components.
GAS LIQUID CHROMATOGRAPHY Principles Partition of molecules between gas (mobile phase) and liquid (stationary phase).
Chapter 32 Gas Chromatography. In gas chromatography, the components of a vaporized sample are separated by being distributed between a mobile gaseous.
Gas Chromatography.
Chapter 32 Gas Chromatography 1. In gas chromatography, the components of a vaporized sample are separated by being distributed between a mobile gaseous.
Gas Chromatography. In Gas Chromatography (GC), a gaseous mobile phase transports a gaseous solute through a long, thin column containing solid or liquid.
K V GOPINATH M Pharm PhD,CPhT Tirumala Tirupati Devasthanams TIRUPATI GAS CHROMATOGRAPHY.
Thermal Conductivity Detector
Gas Chromatography.
M.PRASAD NAIDU Msc Medical Biochemistry, Ph.D Research scholar.
CHROMATOGRAPHY  A laboratory technique in which the components of a sample are separated based on how they distribute between two chemical or physical.
Experiments in Analytical Chemistry
Gas Chromatography Chap 27 Types: Gas-solid chromatography (GSC)
GAS CHROMATOGRAPH. GAS CHROMATOGRAPH Principle: Which type of compounds can analyse? Volatile Thermostable.
An analytical instrumentation process
Chapter 27 Gas Chromatography
Pure Carrier Gas Grades (subjective)
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
VAPOUR PHASE CHROMATOGRAPHY
32A-4 Chromatographic Detectors
GAS CHROMATOGRAPHY.
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
CHROMATOGRAPHY.
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
32A-2 Sample Injection system
Presentation transcript:

Reading assignment: section 26E(p781) Chapter 26 # 2, 3, 14, 15, 16 Chapter 27 # 7(a,d,f), 22, 23, 24, 25

Two types -Gas-solid chromatography (limited because of semipermanent retention of polar molecules) - Gas-liquid chromatography Retention volume F: average volumetric flow rate mL/min, can be determined by measuring flow rate exiting the column using a soap bubble meter Fig (p.790) A soap-bubble flow meter

But V R and V M depend on pressure inside column, and column has resistance to flow -At inlet, P high, F low -At outlet, P low, F high  P  F = constant Pressure drop correction factor j - to calculate average pressure from inlet pressure P i and outlet pressure P

Specific retention volume V g -semi-useful parameter for identifying species eluting Relationship between V g and k

2.1 Carrier gas (mobile-phase gas) He (common), N 2, H 2, P i psi above atom, F = mL/min for packed column, 1-25 mL/min for open tubular capillary Fig (p.790) Block diagram of a typical GS

2.2 Sample injection - Direct injection into heated port to promote fast vaporization -Sample volume 1-20  L for packed column  L for capillary column, a sample splitter is needed (1/50-1/500 to column, rest to waste) or use a purge valve Fig (p.791) Cross-section view of a microflash vaporizer direct injector

2.3Column -Packed column: 1- 5m -Open tubular (capillary): 1m to 100m Both constructed of coiled stainless steel/glass/Teflon, with coil diameter of cm 2.4 Oven: accurate to < 1  C equal or slight high than average boiling point of sample For broad boiling range--temperature programming 2. 5 Detectors Requirement and desire: 1. Sensitive ( g solutes/s) 5. fast response wide dynamic range 2. Stability and reproducibility 6. simple (reliable) 3. Linear response 7. uniform response to all analytes 4. Operate at high T (RT  C)8. nondestructive

Flame Ionization Detector (FID) - Sample pyrolyzed and produce current in electrical field. - Signal depends on #C atoms in organic analyte –mass sensitive not concentration sensitive - Weakly sensitive to carbonyl, halogen, alcohol, amine groups - Insensitive to non-combustibles – H 2 O, CO 2, SO 2, NO X Advantages - Rugged, general applicability, ease of use - Sensitive ( g/s) - Wide dynamic range (10 7 ), low noise Disadvantage - Destructive Fig (p.794) FID

Thermal Conductivity Detector (TCD) -Thermal conductivities of He and H 2 much larger than organics - Organics cause T rise in detector Advantages - Simplicity, general applicability - Wide linear dynamic range (10 5 ) - Responds to both organic and inorganic - Nondestructive Disadvantage - Low sensitivity (10 -8 g/mL carrier gas) Fig (p.794) TCD

Electron Capture Detector (ECD) -electron from  -source ionize carrier gas - organic molecules capture electron and decrease current Advantages - Simple and reliable - Sensitive to electronegative groups (halogens, peroxides) - Largely non-destructive Disadvantages - Insensitive to amines, alcohols, and hydrocarbons - Limited dynamic range (10 2 ) Other detectors: AES, AAS, chemiluminescence reaction, MS, FTIR Fig (p.795) ECD

GC-MS Fig (p.799) GC/MS

3.1 Open tubular columns (Capillary) -Wall coated (WCOT) <1  m thick liquid coating on inside of silica tubing - support-coated (SCOT) 30  m thick coating of liquid-coated support on inside of silica tubing - Best for speed and efficiency but only small samples 3.2 Packed columns - Liquid-coated silica particles (<  m diameter) in glass tubing - Best for large scale but slow and inefficient

3.3 Immobilized liquid stationary phases - Low volatility - High decomposition temperature - Chemically inert (reversible interaction with solvent) - Chemically attached to support (prevent “bleeding”) - Appropriate k and  for good resolution - Many based on polysiloxanes or polyethylene glycol (PEG) - [Check Table 27-2 for common stationary phases for GC]

Stationary phases usually bonded and/or cross-linked for longer-lasting -Bonding – covalent linking of stationary phase to support -Cross-linking – polymerization reactions after bonding to join individual stationary phase molecules Film thickness (0.5-1  M) affects retention and resolution -thicker films for volatile analytes Non-polar stationary phases best for non-polar analytes - non-polar analytes retained preferentially Polar stationary phases best for polar analytes - polar analytes retained preferentially Chiral phases being developed for enantiomer separation (pharmaceutical)

separation + analysis (retention time, retention volumes) 1. Limited for qualitative analysis 2. The area under the peak is proportional to extent of components 3. Retention index Retention index = 100 x number of carbon for normal alkane. Within a homologous series, a plot of log(t R ’)=log(t R -t M ) versus the number of C atoms is linear.