Tel: +44 (0) 1726 879800 www.partech.co.uk Final Effluent Monitoring Application & Product Data.

Slides:



Advertisements
Similar presentations
WHAT IS DRS? Thermoflow, Inc.
Advertisements

Water Quality Testing Made Easy GPS Aquameter and Multiparameter Aquaprobe The perfect solution for your water quality testing needs.
© ABB Group September 1, 2014 | Slide Turbidity Systems Accurate, reliable turbidity measurement.
Wastewater Treatment.
CE 370 Sedimentation.
LEACHATE MANAGEMENT AND TREATMENT
INTRODUCTION TO THE TREATMENT OF TANNERY EFFLUENTS
Welcome Bienvenue Willkommen Bienvenido Добро пожаловать ようこそ 歡迎.
Sewage and Effluent Treatment 2-4 November 2002 Seán Moran -The first few slides.
ENVE 420 Industrial Pollution Control EQUALIZATION Dr. Aslıhan Kerç.
Aquascan. Aquascan - Introduction Aquascan is an online instrument capable of simultaneous multi-parameter measurement for a full range of water quality.
Landfill Water Quality Project Paul Brooks, Lea Bullard, Leslie Harper, Amanda Strickland, Sarah van Schagen April 30, 2004 University of North Carolina.
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
CE 370 Filtration.
Treatment
INTRODUCTION TO THE TREATMENT OF TANNERY EFFLUENTS
You Can Measure the Benefits… Solid Applied Technologies Sewer Level Monitoring.
Surface Water Treatment Plant
Moving Bed Biofilm Reactor MBBR for Nitrification/Denitrification
Coagulation and Flocculation
Representative Sampling By Chuck Abbott. Automatic Samplers.
© ABB Group May 19, 2015 | Slide 1 ABB Analytical Instrumentation Introducing the new Aztec 600 Colorimetric Range.
Nephelometer Introduction & Operation. What is a Nephelometer? The Nephelometer is an analytical instrument used to measure the light-scattering coefficient.
Introduction to Environmental Engineering
Introduction: We will start with an overview of treatment processes 1) Why do we treat water and wastewater? The main objectives of the conventional wastewater.
EKT314/4 Electronic Instrumentation
PAJ GROUP WE BELIEVE IN QUALITY Development & production of advanced mechatronics.
Water and Wastewater Focus Wireless Sales Push 2009.
Solids Measurement by Gravimetry n Objective n to understand the difference between the various Solids fractions that occur in Water, Effluent and Sludge.
Applications for CBX Sludge Blanket Meter Savings and optimization of the process.
Tel: +44 (0) Turbidity Application and Product Data.
Overview of Continuous Water-Quality Monitoring. Purpose of Monitoring Define the objectives of the water quality monitoring project 1. Environmental.
Solid Applied Technologies Gauger Compact, continuous, non-contact, loop- powered, ultrasonic level meter: Simple installation and configuration.
Human Waste Disposal  More than 500 pathogenic bacteria, viruses, and parasites can travel from human or animal excrement through water.  Natural Processes.
E NVIRONMENTAL E NGINEERING 441 Lecture 5: Water Treatment (3) Sedimentation & filtration Philadelphia University Faculty of Engineering Department of.
File Name: Turbidity.pptFeb 2001 Turbidity & Suspended Solids Overview.
SEWER MINING.
Representative Sampling. Samples vs. Populations The population is the total or all of the possible answers we might get by sampling. All of the individuals.
ChemScan ® mini oP Ortho-Phosphate Analyzer (click to advance slides)
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
ACWA – RECYCLE RESEARCH Presentation to the ACWA National Convention August 2009.
Waste Treatment, Physical
Introduction to Environmental Engineering Dr. Kagan ERYURUK
Water Horner APG, LLC June 4, What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured.
Presentation by Chelsea Smith March 11, My Background Southern Wells (K-12) Graduated in 2010 Ball State University ( ) BS in Environmental.
Wastewater Treatment Principles and Regulation. What is Wastewater? Sewage released by residences, businesses and industry Contains liquid and solid components.
Engineered systems for wastewater treatment and disposal.
Membrane Bioreactors for Wastewater Treatment.
WATER MANAGEMENT.
Tel: +44 (0) Dissolved Oxygen.
Conventional Sewage Treatment Plants:
EMSA 22 Lab Module 1 Field Equipment Calibration
ACWA – RECYCLE RESEARCH
Lecture (8): liquid wastes treatment (primary, vital, advanced).
Wastewater Treatment.
Wastewater Treatment.
Drinking-water Treatment
Wastewater Treatment.
Filtration Technologies Comparison for Tertiary Treatment
Experience Nordic Water WesTech / General Filter
Pilot testing services and a case study to reduce organics Devendra Borikar, Laura Zettler, Jeff Avedesian, Lindsay Ariss, Luc Léonard, Denis Dolbec,
Typical Drainage system
Hanmer Springs Water Supply
Wastewater Treatment.
Turbidity - “A Quantum Leap in Technology” Southwest Section AWWA
Wastewater Treatment Secondary Treatment.
Wastewater Treatment: Characteristics and Systems
Wastewater Treatment.
Wastewater Treatment.
Water Treatment.
Presentation transcript:

Tel: +44 (0) Final Effluent Monitoring Application & Product Data

Final Settlement River Tertiary Treatment Plant Wastewater or Industrial Effluent Treatment Plant

Final Effluent Channel Package Plant Outlet River Discharge Point Effluent Monitoring

The effluent monitor is the policeman at the end of the treatment process. Providing an alarm when the effluent quality is deteriorating. A change in the effluent conditions can indicate a process that is starting to fail, providing an early warning. An effluent monitor can pick up high levels of residual dosing chemicals that are not being used correctly, this indicates an overdosing condition. When the effluent quality is very good, it is often possible to bypass or modulate high energy tertiary treatment plants. Why is Effluent Monitoring Important?

From upstream process Tertiary Treatment UV, Sand Filter, Membrane Plant or similar Clarifier Effluent River Monitoring at allows the operator to inhibit use of the tertiary treatment system when: The effluent is of a good quality and further treatment is not required The effluent is too poor a quality and could damage the tertiary treatment plant Monitoring at allows the operator to inhibit use of the tertiary treatment system when: The effluent is of a good quality and further treatment is not required The effluent is too poor a quality and could damage the tertiary treatment plant Clarifier Return to upstream process Tertiary Treatment Control

Safe easy access to sensor and electronics Avoid Turbulence Avoid Other Sensing Structures Find Representative sample point of the process Well mixed sample Safe to reach sensors Find Representative sample point of the process Well mixed sample Safe to reach sensors Avoid Dead Zone Extreme Turbulence Other Instrumentation Hazardous access to sensor Reaching over handrails Avoid Dead Zone Extreme Turbulence Other Instrumentation Hazardous access to sensor Reaching over handrails Ensure Success – Pick your Location

Flow Where should the Turbidity or pH sensor go? Ultrasonic Level Sensor for flow measurement Sensors in Flumes

Flow Upstream of ultrasonic sensor, in controlled flow area Ultrasonic Level Sensor for flow measurement Not here – it would interfere with level measurement Not here – to turbulent and can’t guarantee level Sensor in Flumes

Flow Upstream of ultrasonic sensor, in controlled flow area Ultrasonic Level Sensor for flow measurement Not here – it would interfere with level measurement Not here – to turbulent and can’t guarantee level Not here – to turbulent InletOutlet V-Notch Weir Plate Sensors in Weir Boxes

pH, Conductivity, Temperature Turbidity or Suspended Solids UV254 as a surrogate for COD or as an indication of transmissivity for control of UV treatment Nutrients – Ammonia, Phosphate Residual Dosing Chemicals – Iron, Aluminium Parameters

Turbidity is recognised as an excellent general indicator of process performance Increasing Turbidity provides an early warning of a failure in the treatment process Increasing Turbidity can give a surrogate indication of an increase in more complex measurements such as BOD and COD Increasing Turbidity highlights problems with Pin Floc created by overdosing of Flocculation and Coagulation chemicals such as Aluminium and Iron Salts used for P Removal Why Measure Effluent Turbidity

Suspended Solids - Definition The mass of dry solid material in a sample, the only true measurement is taken using a laboratory method involving manual filtration and drying of the sample (Standard Method: 2540D) Abbreviated as TSS or SS Online sensors use inferential methods, relying on a calibration based on the laboratory method above Turbidity - Definition Optical parameter indicating the clarity or cloudiness of a liquid Wikipedia - Turbidity is the cloudiness or haziness of a fluid caused by individual particles (suspended solids) that are generally invisible to the naked eye, similar to smoke in air. The measurement of turbidity is a key test of water quality. Typically units of FTU and NTU are used with calibration against a ??? standard Suspended Solids or Turbidity

Matches consent rule Represents each site Ease of calibration Comparable site to site Suspended Solids or Turbidity Turbidity Suspended Solids

Another general indicator of process performance pH outside of normal ambient levels indicates that the effluent is likely to be toxic Varying pH indicates that the process is out of control A drift to either high or low pH can indicate that under or overdosing is occurring in the process Sudden changes indicate that a major incident or change in plant loading has occurred Why Measure Effluent pH

Measurement of UV light at 254nm cannot be universally applied BUT For some effluents it will provide a low cost alternative to an online COD analyser Good for: Nitrate not for Ammonia Good for organics containing a Benzene Ring (Aromatic) compound Often referred to a SAK(C) – spectral Absorption Coefficient Provides an output in mg/l Carbon UV Transmissivity will provide a control signal to modulate or inhibit UV treatment UV254 – OPM and UV Transmissivity

Laboratory Tests Sample sent away Results not known until at least 24hrs after the event Sample degrades in transit Site Settling Jars/Handheld Meter Very operator dependent Takes 30 minutes Portable Monitor Calibration can be made to same standards as fixed installation systems Available when operator is on site, manual adjustment possible Fixed Installation Monitor 24/7 Monitoring Automated control possible Measurement Options

Pro’s Continuous In-Line Monitoring reduces the need for time-consuming laboratory analysis Removes operator dependency from the measurement Real-time monitoring provides more accurate process control Improves plant efficiency by providing stability and continuity to the treatment process Conn’s Capital costs Whole life costs Benefits of Online Monitoring

7300w 2 Monitor WaterWatch² Partech’s versatile electronics platform

7300w² and 7200w² Monitor / Controller Advanced Features 1 or 2 sensor input. Multiple Parameter Capability via optional interface unit. Graphic display with trending USB Interface for data logging for each measurement. Fully Featured Dosing Control. PID plus. Conventional or Profibus output. Triple validation option Low Power Operation, ability to lay dormant when intermittent sampling is required. Easy to use menu structure.

Example of an Application

The cleaning action is thorough & effective ! Fit for purpose !

TurbiTechw 2 LS Light Scatter Principle. 860nm Wavelength Designed for use in wastewater applications. Sensor can measure both inlet and outfall (discharge) Turbidity Can be calibrated for Suspended solids monitoring TurbiTechw 2 LS Large optical surface & sample volume ensures tolerant of fouling. Deposits of fats and grease on the sensor area do not prevent the sensors from measuring unlike smaller optical surfaces. Self Cleaning mechanism. Initiated by monitor at user determined frequency. Cleaning process only takes 90 seconds Rugged & Robust sensor designed for the application Concentration C Light Intensity I o Light Intensity I Suspended Solids – TurbiTechw² LS Sensor

WaterTechw² pH8000 pH and Temperature Applications Inlet Monitoring Final Effluent Drinking Water WaterTechw² Redox8000 Redox and Temperature Applications Intake Protection ASP Control pH and Redox

Sensor Fouling - The TurbiTech sensors have an integral automatic self cleaning system. - Optional. Sensors can be retracted and then extended when required for readings. Air Bubbles - Good Installation practise reduces problems, high damping on the reading reduces the problem Varying Sampling Characteristics - Not a problem in activated sludge process Installation Consideration

Avoid ProsecutionSave money Improve response to process changes Remove operator error from process adjustment Good Effluent Monitoring will help: Summary

Tel: +44 (0) Andrew Wallace - Field Sales Engineer Mobile: Angus Fosten - Sales and Marketing Director Mobile: +44 (0) Clive Teobald - Sales Engineer Mobile: David Wilson- Export Sales Manager Mobile: +44 (0) Jan Johnson - Sales Administrator