1 Impact de l’effet faisceau-faisceau sur la precision de la mesure de la luminosité à l’ILC Cécile Rimbault, LAL Orsay SOCLE,19-20 Novembre 2007, Clermont-Ferrand.

Slides:



Advertisements
Similar presentations
GUINEA-PIG: A tool for beam-beam effect study C. Rimbault, LAL Orsay Daresbury, April 2006.
Advertisements

Study of alternative optical parameters for the ILC final focus On-going work and plans Philip Bambade Laboratoire de l’Accélérateur Linéaire Université.
Zhiqing Zhang (LAL, Orsay) 30/5-3/6/ SM Background Contributions Revisited for SUSY DM Stau Analyses Based on 1.P. Bambade, M. Berggren,
TESLA R&D: LCAL/LAT Achim Stahl DESY Zeuthen Cracow Tel Aviv Minsk Prague Colorado Protvino UCL London Dubna.
P hysics background for luminosity calorimeter at ILC I. Božović-Jelisavčić 1, V. Borka 1, W. Lohmann 2, H. Nowak 2 1 INN VINČA, Belgrade 2 DESY, Hamburg.
NLC - The Next Linear Collider Project  IR background issues and plans for Snowmass Jeff Gronberg/LLNL Linear Collider Workshop October 25, 2000.
ILC Machine-Detector Interface Challenges Philip Bambade LAL-Orsay Workshop on the Future Linear Collider Gandia, Spain, December 1, 2005.
Beam-beam simulations M.E. Biagini, K. Ohmi, E. Paoloni, P. Raimondi, D. Shatilov, M. Zobov INFN Frascati, KEK, INFN Pisa, SLAC, BINP April 26th, 2006.
20 March 2005Ken Moffeit LCWS1 Highlights from the MDI workshop Spin Rotation System for 2 IR’s Downstream polarimetry Ken Moffeit.
I. Božović-Jelisavčić, LCWS10, Beijing, March LUMINOSITY MEASUREMENT AT ILC I. Bozovic-Jelisavcic (on behalf of the FCAL Collaboration)
M. Woods (SLAC) Beam Diagnostics for test facilities of i)  ii) polarized e+ source January 9 –11, 2002.
August 2005Snowmass Workshop IP Instrumentation Wolfgang Lohmann, DESY Measurement of: Luminosity (precise and fast) Energy Polarisation.
Ronen Ingbir Collaboration High precision design Tel Aviv University HEP Experimental Group Krakow2006.
Precise Measurements of SM Higgs at the ILC Simulation and Analysis V.Saveliev, Obninsk State University, Russia /DESY, Hamburg ECFA Study Workshop, Valencia.
BeamCal Simulations with Mokka Madalina Stanescu-Bellu West University Timisoara, Romania Desy, Zeuthen 30 Jun 2009 – FCAL Meeting.
Luminosity Monitoring and Beam Diagnostics FCAL Collaboration Workshop TAU, September 18-19, 2005 Christian Grah.
Analysis of Beamstrahlung Pairs ECFA Workshop Vienna, November 14-17, 2005 Christian Grah.
Beam Monitoring from Beam Strahlung work by summer students  Gunnar Klämke (U Jena, 01)  Marko Ternick (TU Cottbus, 02)  Magdalena Luz (HU Berlin, 03)
ILC Meeting Vancouver July What Does Beam-strahlung Tell Us? William Morse - BNL.
Top threshold Monte Carlo generator Stewart Boogert John Adams Institute Royal Holloway, University of London Filimon Gournaris (Ph.D student and majority.
Ivan Smiljanić Vinča Institute of Nuclear Sciences, Belgrade, Serbia Energy resolution and scale requirements for luminosity measurement.
Trilinear Gauge Couplings at TESLA Photon Collider Ivanka Božović - Jelisavčić & Klaus Mönig DESY/Zeuthen.
Simulation of Beam-Beam Background at CLIC André Sailer (CERN-PH-LCD, HU Berlin) LCWS2010: BDS+MDI Joint Session 29 March, 2010, Beijing 1.
Karsten Büßer Instrumentation of the Forward Region of the TESLA Detector International Europhysics Conference on High Energy Physics Aachen, July 19th.
ILC-ECFA Workshop Valencia November 2006 Four-fermion processes as a background in the ILC luminosity calorimeter for the FCAL Collaboration I. Božović-Jelisavčić,
Beam Monitoring from Beam Strahlung new work by summer students  Magdalena Luz (HU)  Regina Kwee (HU) Achim Stahl DESY Zeuthen 10.Oct.2003 LumiCal BeamCal.
Fast Beam Diagnostics at the ILC Using the Beam Calorimeter Christian Grah, Desy FCAL Workshop February Cracow.
Implementation and study of depolarizing effects in GUINEA-PIG++ beam-beam interaction simulation Advanced QED Methods for Future Accelerators 3 rd -4.
Philip Bambade - LALLCWS04 - MDI 20/4/20041 Crossing-angle-or-not physics implications report from phone-meeting cold half-angle = 10, 4, 1, 0.3,……
TESLA R&D: Forward Region Achim Stahl DESY Zeuthen Cracow Tel Aviv Minsk Prague Colorado Protvino UC London Dubna.
Study of alternative ILC final focus optical configurations Dou Wang (IHEP), Yiwei Wang (IHEP), Philip Bambade (LAL), Jie Gao (IHEP) International Workshop.
HEP Tel Aviv University LumiCal (pads design) Simulation Ronen Ingbir FCAL Simulation meeting, Zeuthen Tel Aviv University HEP experimental Group Collaboration.
Pad design present understanding Tel Aviv University HEP Experimental Group Ronen Ingbir Collaboration High precision design Tel-Aviv Sep.05 1.
1 O. Napoly ECFA-DESY Amsterdam, April 2003 Machine – Detector Interface : what is new since the TDR ? O. Napoly CEA/Saclay.
Top/QCD program (b) Higher Order EW + QCD Fixed order vs resummed Normalization (and peak position) stabilised by higher orders; –summation of leading.
1 Experience at CERN with luminosity monitoring and calibration, ISR, SPS proton antiproton collider, LEP, and comments for LHC… Werner Herr and Rüdiger.
First Collision of BEPCII C.H. Yu May 10, Methods of collision tuning Procedures and data analysis Luminosity and background Summary.
Inputs from GG6 to decisions 2,7,8,15,21,27,34 V.Telnov Aug.24, 2005, Snowmass.
1 Calorimeters of the Very Forward Region Iftach Sadeh Tel Aviv University DESY Collaboration High precision design March 5 th 2008.
16 February 2009CLIC Physics & Detectors Konrad Elsener 1... some issues regarding the forward region... (“picking up” from Lucie Linssen, 29 Sept 2008)
The Luminosity Calorimeter Iftach Sadeh Tel Aviv University Desy ( On behalf of the FCAL collaboration ) June 11 th 2008.
The Very Forward Region of the ILC Detectors Ch. Grah FCAL Collaboration TILC 2008, Sendai 04/03/2008.
Beam-Beam interaction SIMulation: GUINEA-PIG C. Rimbault, LAL Orsay CARE 05, Geneva, November 2005.
Systematic limitations to luminosity determination in the LumiCal acceptance from beam-beam effects C. Rimbault, LAL Orsay LCWS06, Bangalore, 9-13 March.
Impact of electromagnetic deflection due to beam-beam effect on Bhabha scattering C. Rimbault, LAL Orsay Krakow, February
Fast and Precise Luminosity Measurement at the ILC Ch.Grah LCWS 2006 Bangalore.
Correction methods for counting losses induced by the beam-beam effects in luminosity measurement at ILC Ivan Smiljanić, Strahinja Lukić, Ivanka Božović.
GUINEA-PIG: Beam-beam interaction simulation status M. Alabau, P. Bambade, O. Dadoun, G. Le Meur, C. Rimbault, F. Touze LAL - Orsay D. Schulte CERN - Genève.
LumiCal background and systematics at CLIC energy I. Smiljanić, Vinča Institute of Nuclear Sciences.
Boogert and Miller; Luminosity Measurement questions; calorimeter-related. 1 Luminosity Measurement questions; calorimeter-related Stewart Takashi Boogert.
Octobre 2007LAL Orsay Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY.
ILC BDS Commissioning Glen White, SLAC AWLC 2014, Fermilab May 14 th 2014.
Experimental considerations about  physics at DA  NE2 F. Anulli, D. Babusci, G. Pancheri Laboratori Nazionali di Frascati  Physics window at DA  NE2.
How well do we need to know the luminosity spectrum at 3 TeV CLIC? Lucie Linssen, CERN on behalf of the CLIC physics and detector study, material principally.
1 Updated comparison of feedback implementation for e + e - and e - e - modes of operation with realistic errors in the BDS M. Alabau Pons, P. Bambade,
Initial proposal for the design of the luminosity calorimeter at a 3TeV CLIC Iftach Sadeh Tel Aviv University March 6th 2009
Beam-Beam interaction SIMulation: GUINEA-PIG
1 April 1 st, 2003 O. Napoly, ECFA-DESY Amsterdam Design of a new Final Focus System with l* = 4,5 m J. Payet, O. Napoly CEA/Saclay.
Luminosity Measurement using BHABHA events
The Interaction Region
Summary of the FCAL Workshop Cracow, February 12-13
Emmanuel Tsesmelis TS/LEA 26 January 2007
Other beam-induced background at the IP
GUINEA-PIG++ Workshop on Spin Simulation Tools, 9-11 Nov 2010, DESY
Higgs Physics at a gg Collider
Preliminary results on depolarization due to beam-beam interaction at SuperB Cecile Rimbault LAL - Orsay.
Study of e+ e- background due to beamstrahlung for different ILC parameter sets Stephan Gronenborn.
Top Threshold at the ILC
Beam-beam simulations
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

1 Impact de l’effet faisceau-faisceau sur la precision de la mesure de la luminosité à l’ILC Cécile Rimbault, LAL Orsay SOCLE,19-20 Novembre 2007, Clermont-Ferrand

Cécile Rimbault, LAL Orsay Principe de la mesure de luminosité via la diffusion Bhabha Modifications induites par l’effet faisceau-faisceau Conséquences sur la précision accessible pour la luminosité Dépendance avec les paramètres du faisceau et l’énergie de la collision Conclusions Impact de l’effet faisceau-faisceau sur la precision de la mesure de la luminosité à l’ILC

Bhabha particles are detected in coincidence in the luminosity monitor LumiCal covering a range of 26.2 to 82 mrad. L= N Bh /  Bh from counting rate  integrated luminosity Measurement of energy and scattering angle of the Bhabhas  luminosity spectrum reconstruction Physics needs:  L/L : Luminosity measurement in the LumiCal using Bhabha scattering at small angles

Bhabhas are produced with BHLUMI, √s = 500 GeV, 25<  <90 mrad, ISR include Beam-Beam effect treatment with GUINEA-PIG (Nominal beam param. used for simul.) Modification of initial state: Beamstrahlung  √s’≤√s,  ini ≠ 0, E elec ≠ E posit Modification of final state: Electromagnetic deflections  bhabha angle reduction (~10 -2 mrad) + small energy losses Beam-Beam effects on Bhabha scattering

5 First study with the following selection cuts : E beam  Suppression of Bhabha particles within selection cuts: the bias is defined as (N theor – N exp )/N theor Due to modification of initial state = beamstrahlung: (-3.78 ± 0.04)% Due to modification of final state = EM deflections: (-0.65 ± 0.02)% Total BHabha Suppression Effect (BHSE): (-4.41 ± 0.05)% Why is there such an important Bias ? Consequences on integrated luminosity measurement: Reduction of Bhabha counting rate - 1

6 Bhabha0 Bhabha1 Beamstrahlung  enhancement of acollinearity:    = 1.27 mrad    = 2.00 mrad The angular cut should not be symmetric: new asymmetrical cuts 30 mrad<  -+ <75 mrad & 26.2 mrad<  +- <82 mrad ref. A. Stahl LC-DET Reduction of Bhabha counting rate - 2 Angular cuts optimization

7 Beamstrahlung & EM deflections: Bhabha energy reduction + energy asymmetry enhancement  use global energy cut: E + + E - > 0.8√s BHSE from Beamstrahlung BHSE from EM deflections Total BHSE Reduction of Bhabha counting rate - 3 Energy cuts optimization

8 Suppression of Bhabha particles inside the selection cuts E beam : Due to modification of initial state = beamstrahlung: (-3.78 ± 0.04)% Due to modification of final state = EM deflections: (-0.65 ± 0.02)% Total BHabha Suppression Effect : (-4.41 ± 0.05)% Suppression of Bhabha particles inside the optimized selection cuts 30 mrad 0.8√s : Due to modification of initial state = beamstrahlung: (-1.03 ± 0.04)% Due to modification of final state = EM deflections: (-0.48 ± 0.02)% Total BHabha Suppression Effect : (-1.51 ± 0.05)%  The bias on integrated luminosity measurement is reduced about a factor 3 with asymmetric angular cuts and global energy cut. Consequences on integrated luminosity measurement: Reduction of Bhabha counting rate - 4

9 Reconstruction of luminosity spectrum from lumical Experimentally, EMdeflections have no impact on the reconstructed lumi spectrum.  Beamstrahlung can still be measured with lumi spectrum  EMdeflections can not be controlled directly...    ISR ISR+BS ISR+BS+EMdef x exp from K. Mönig ref. LC-PHSM TESLA

10 Sensitivity of BHSE to the beam parameters BHSE is not sensitive to beam offsets,  x and  y,, to longitudinal shifts of the bunch waist and to vertical size of the bunch. BUT BHSE has strong dependence on bunch length,  z, and horizontal size,  x BHSE from Beamstrahlung BHSE from EM deflections Total BHSE  z (  m)  x (nm)

11 Sensitivity of BHSE to energy - 1 ILC should enable physics runs initially for energies from the Z boson mass to 500 GeV  In this energy range beam-beam effects are strongly modified BHSE from Beamstrahlung BHSE from EM deflections Total BHSE With constant beam optical parameters

12 Sensitivity of BHSE to energy - 2 ILC should enable physics runs initially for energies from the Z boson mass to 500 GeV  In this energy range beam-beam effects are strongly modified BHSE from Beamstrahlung BHSE from EM deflections Total BHSE Constant luminosity At low energy, EM contribution of BHSE becomes dominant, reaching few 100*10 -4 Constant beam parameters

13 Summary & Conclusions - 1 Beam-beam effects on Bhabha scattering increase acollinearity (+0.7 mrad) and energy asymmetry on the Bhabha particles  Need to find a compromise with background suppression cuts This leads to a bias on the integrated luminosity measurement of the order of , depending on selection cuts and beam parameters BHabha Suppression Effect mainly arises from beamstrahlung (for Nominal ILC) The reconstructed luminosity spectrum in the LumiCal is almost not modified by EM deflections  beamstrahlung can be measured from the lumi spectrum reconstruction Main dependencies are from the horizontal and longitudinal sizes of the bunch. A precision of 20% is needed on their knowledge to limit the error on BHSE from EM deflections to about To reach a precision of on luminosity, a precision better that 5% is needed on  x and  z.

14 Summary & Conclusions - 2 No direct way to control experimentally the bias from EM deflections, but measurements of beam angular divergence in extraction line could provide a way to monitor lumi bias from  x variations. For  z ?  Need to use a simulation tool: CAIN, GUINEA-PIG and GUINEA-PIG++ for further studies. For the GigaZ option, a precision of is needed for the luminosity, while the bias from EM deflections is >100 x  need more complete studies. “Impact of beam-beam effects on precision luminosity measurements at ILC”, C. Rimbault, P. Bambade, K. Mönig, D. Schulte, EuroTeV-Report , JINST 2 P09001.