Simulations in Medical Physics Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, M.KACI**, G.AMOROS**, *Université Mohammed V –Agdal, Faculté des Sciences de Rabat,

Slides:



Advertisements
Similar presentations
What are PET basics?.
Advertisements

GATE a simulation platform for nuclear medicine based on GEANT4
Computer Simulation for Emission Tomography: Geant4 and GATE Xiao Han Aug
Computers and Computed Tomography
6: Positron Emission Tomography
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
Chapter 8 Planar Scintigaraphy
Buxton & District Science Discussion Medical Scanners Marge Rose 16 th November 2012.
Fysisk institutt - Rikshospitalet 1. 2 Overview Gamma camera Positron emission technology (PET) Computer tomography (CT) Proton therapy Electrical impedance.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Imaging PET Course Layout Class + ContentDateClass Physical Principles of PET I Physical principles of MRI II Imaging applications III.
Simulation System for Emission Tomography (SimSET): using the new block detector feature. Robert L. Harrison, William C. J. Hunter, Steven B. Gillispie,
Examples of GATE simulation Yun Dong. Different systems available in GATE Scanner: most generic system; Cylindrical PET: cylindrical geometry; CPET: simulate.
Kirov A S, MSKCC Overview of Geant4 Use and Issues in Imaging: Emission Tomography (PET and SPECT) Assen S. Kirov Department of Medical Physics Memorial.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Coincidence imaging today
Very High Resolution Small Animal PET Don J. Burdette Department of Physics.
Medical Image Analysis Medical Imaging Modalities: X-Ray Imaging Figures come from the textbook: Medical Image Analysis, Second Edition, by Atam P. Dhawan,
Coincidence to Image: PET Imaging Jennifer White Marketing Manager SNS Workshop October 13, 2003.
St. Petersburg State University. Department of Physics. Division of Computational Physics. COMPUTER SIMULATION OF CURRENT PRODUCED BY PULSE OF HARD RADIATION.
Design and simulation of micro-SPECT: A small animal imaging system Freek Beekman and Brendan Vastenhouw Section tomographic reconstruction and instrumentation.
0 A Fast Time Incorporating Monte-Carlo Simulation of Wire Chamber Based Small Animal PET Scanners for Detector Scatter Correction M. Dawood 1, Don Vernekohl.
Innovation is in our genes. 1 Siemens Medical Solutions Molecular Imaging What are SPECT basics?
Fundamental Limits of Positron Emission Tomography
Medical Image Analysis Dr. Mohammad Dawood Department of Computer Science University of Münster Germany.
Accurate gamma-ray spectrometry of environmental samples: a challenge O. Sima - Bucharest University D. Arnold - PTB Braunschweig C. Dovlete - ERL Bucharest.
First Results from a Test Bench for Very High Resolution Small Animal PET Using Solid-State Detectors Klaus Honscheid for The CIMA Collaboration The Ohio.
Single Photon Emission Computed Tomography
BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 1 Biomedical Imaging I Class 5 – Radionuclide Imaging (PET, SPECT), Part 3: Attenuation and Scatter.
Professor Brian F Hutton Institute of Nuclear Medicine University College London Emission Tomography Principles and Reconstruction.
PET/SPECT Phantom. Side View of Phantom Image Resolution Intrinsic resolution FWHM Intrinsic resolution FWHM Field of view Field of view Measurement:
M. D. A NDERSON Cancer Center Nuclear Imaging (M.Cam) Richard E. Wendt III, Ph.D. and William D. Erwin, M.S. Small Animal Cancer Imaging Research Facility.
Where do our data come from? Positron Emission Tomography (PET)
Introduction to Modern Medical Imaging
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
16. January 2007Status Report On Compton Imaging Projects 1 Status Of Compton Imaging Projects Carried Out In The CIMA Collaboration HPD Brain PET Meeting.
Seoul National University Functional & Molecular Imaging System Lab Progress in Nuclear Imaging Mikiko Ito, PhD Dept. of Nuclear Medicine, Seoul National.
SAFIR: a fast PET insert for pre-clinical MRI with high temporal resolution Becker Robert 1, Jean-Pierre Cachemiche 2, Casella Chiara 1, Dissertori Günther.
Enhancing InBeam PET with single Photon (Compton) Detection CERN September 2nd 2008 VALENCIA GROUP, IFIMED José M. Benlloch (PET hardware, speaker) José.
A Single Photon Emission Computer Tomograph for breast cancer imaging S. Vecchio a, N. Belcari a, P. Bennati b, M. Camarda a, R. Campanini c, M. N. Cinti.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Impact of Axial Compression for the mMR Simultaneous PET-MR Scanner Martin A Belzunce, Jim O’Doherty and Andrew J Reader King's College London, Division.
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
Improved Hybrid PET Imaging Using Variable Focal Length Fan-Slat Collimators Thomas C. Rust and Dan J. Kadrmas, Ph.D. Medical Imaging Research Laboratory.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
RPC February 2010 SPATIAL RESOLUTION OF HUMAN 3D RPC-PET SYSTEM 1 LIP, Laboratório de Instrumentação e Física Experimental de Partículas, Coimbra,
Presentation of Master of medical and imagery physics Rajaa Cherkaoui El Moursli, Mohammed V – Agdal University, Rabat, Morocco Hassan II Academy of Sciences.
L/O/G/O Filtering images by Using a New Approach of Anisotropic Diffusion Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, L.MASMOUDI*, M. CHERKAOUI MALKI**. *Université.
Institute of Basic Science Rare Isotope Science Project PANGEA P hoton detector system for A stro-science and N uclear physics with GE rmanium A rray 2015.
a Very Interesting Presentation
GATE application example using SuperComputer 국립암센터 박 세 준 연구원.
Andy Boston Imaging devices for medicine and security.
PET Imaging Positron Emission Tomography
Chapter-5 Positron emission tomography (PET)
+ Voxel Imaging Pizza Gianluca De Lorenzo. + Positron Emission Tomography April Gianluca De Lorenzo.
P.E.T. Positron Emission Tomography
Positron emission tomography: a review of basic principles, scanner design and performance, and current systems  Pat Zanzonico  Seminars in Nuclear Medicine 
Trigger System for a Thin Time-of-flight PET scanner
Prof. Stefaan Vandenberghe Enrico Clementel
SIMULATION AND IMAGE RECONSTRUCTION OF CLINICAL TOF-PET SCANNERS
Reconstructions with TOF for in-beam PET
Detailed simulations of a full-body RPC-PET scanner
Summary of the Compton-PET project
Monte Carlo Simulation
Presentation transcript:

Simulations in Medical Physics Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, M.KACI**, G.AMOROS**, *Université Mohammed V –Agdal, Faculté des Sciences de Rabat, Maroc ** Instituto de Física Corpuscular, Universitat de València/CSIC, Spain

Introduction TOUFIQUE Yassine workshop Valencia 2012

GATE is an advanced opensource software developed by the international OpenGATE collaboration and dedicated to numerical simulations in medical imaging and radiotherapy. It currently supports simulations of Emission Tomography (Positron Emission Tomography - PET and Single Photon Emission Computed Tomography - SPECT), Computed Tomography (CT) and Radiotherapy experiments. # W O R L D # /gate/world/geometry/setXLength 400. cm /gate/world/geometry/setYLength 400. cm /gate/world/geometry/setZLength 400. cm # E C A T E X A C T H R + P E T S C A N N E R /gate/world/daughters/name ecat /gate/world/daughters/insert cylinder /gate/ecat/setMaterial Air # R E P E A T P M T /gate/PMT/repeaters/insert cubicArray /gate/PMT/cubicArray/setRepeatNumberX 1 /gate/PMT/cubicArray/setRepeatNumberY 2 /gate/PMT/cubicArray/setRepeatNumberZ 2 GATE : Geant4 Application for Tomographic Emission OPET scannerSPECT CylindricalPET Ecat PET Radiotherapy TOUFIQUE Yassine workshop Valencia 2012

PET:(Positron tomographic emission )  now a well established diagnostic modality that is extensively used in oncology for tumour diagnosis.  is based on the detection, in coincidence, of two 511 keV photons emitted, at 180º from each other. TOUFIQUE Yassine workshop Valencia 2012

The NEMA NU Test Protocol NEMA scatter fraction phantom Line Source Polyethylene A sensitivity measurement phantom: (a) schematic diagram, (b) actual phantom viewed end-on. The NEMA NU protocol has been designed for the performance evaluation of whole-body PET measurements with scanners acquiring data in 3-D mode. This protocol includes a number of tests to check the different aspects of scanner performance, which comprises : - Spatial resolution - Scatter fraction, count losses, and random measurements - Sensitivity - Accuracy of corrections for count losses and random - Image quality, accuracy of attenuation, and scatter corrections The National Electrical Manufacturers Association TOUFIQUE Yassine workshop Valencia 2012

Description of the ECAT HR+ PET Scanner ParametersEcat exact HR+ Detector MaterialBGO Crystal Dimension (mm 3 )4,05x4,39x30 Detector Ring Diameter (cm)82,4 Transverse Field of View (cm)58,3 Axial Field of View (mm)155 Coincidence Time Windows (nsec)12 ECAT Exact HR+ PET scanner is a commercial Siemens scanner consisting in consists of 4 block rings of 72 detector blocks each. Each block is constructed of an 8×8 BGO crystal array. The dimensions of each crystal element are 4.05mm×4.39mm×30 mm. The detector ring diameter is 82.4 cm while the axial FOV is 155mm. PMTs Crystals TOUFIQUE Yassine workshop Valencia 2012

Parameters and digitizer for the simulation of ECAT HR+ PET Signal processor chain Geant4 Hits Pulses Readout/ block Energy resolution efficiency deadtime/ block Energy Window 511keV 88% 5000ns Paralysable 300/650keV Singles Gate Coincidences deadtime 500ns Paralysable Final Coincidences Parameters Lowenergy models for Compton and Rayleigh Energy cuts: delta-ray 10 keV, X-rays 10 keV, Electron range cut 2 mm Coincidence time window 12 nsec Energy window (in spectra) keV TOUFIQUE Yassine workshop Valencia 2012

Schematic representation of a LOR within a transaxial plane. True ScattedRandommultiple Line of Response and Detected events in PET Representation of a sinogramme 2D TOUFIQUE Yassine workshop Valencia 2012

Results of PET simulation TOUFIQUE Yassine workshop Valencia 2012

Results 1 TOUFIQUE Yassine workshop Valencia 2012

Results 2 TOUFIQUE Yassine workshop Valencia 2012

Results : Comparisons MEASUREDSIMULATED SCATTER FRACTION 46 %44 % MEASUREDSIMULATED SENSITIVITY T.O.P = 0 cm6650 cps/MBq6877 cps/MBq T.O.P = 10 cm7180 cps/MBq7235 cps/MBq Ratio (0 cm/10 cm) T.O.P : Transaxial Offset Position Energy window (keV) The SCATTER FRACTION is the ratio of scattered events to total events (at low counting rate). The SENSITIVITY of a scanner represents its ability to detect annihilation radiations. TOUFIQUE Yassine workshop Valencia 2012

Activity (MBq) Nb Jobs Success Time (h) Results: using GATE on the Grid We need to perform a simulation with 528 MBq source activity. We test GATE on the Grid. Execution time of simulations is limited by the Proxy duration : 48 h

brachytherapy the internal radiation treatment achieved by implanting radioactive material directly into the tumor or very close to it. Catheter Water Phantom Experience: TOUFIQUE Yassine workshop Valencia 2012

brachytherapy TOUFIQUE Yassine workshop Valencia 2012

Slide 96/201

TOUFIQUE Yassine workshop Valencia 2012  Follow up the present study Conclusion