1 SIMS Characterization of Impurity Elements in Nb: The Effect of Heat Treatments ncsu.edu/aif jlab.org 1 P. Maheshwari, F. Stevie, D. Griffis, M. Rigsbee.

Slides:



Advertisements
Similar presentations
Secondary Ion Mass Spectrometry
Advertisements

Ion Beam Analysis techniques:
AMCF Materials Characterization School 2012 X-Ray Photoelectron Spectroscopy Tim Morgan.
Hamamatsu, November 2007 Methods and Tehniques in Surface Science Prof. Dumitru LUCA “Alexandru Ion Cuza” University, Iasi, Romania.
1 EFFECTS OF CARBON REDEPOSITION ON TUNGSTEN UNDER HIGH-FLUX, LOW ENERGY Ar ION IRRADITAION AT ELEVATED TEMPERATURE Lithuanian Energy Institute, Lithuania.
ERDA, for measurement of hydrogen in PV applications
Cr and Co release reduction from stainless steels in PWR and BWR 2009 ISOE Asia ALARA Symposium Aomori EPRI Radiation Protection Conference September 9,
Study of sputtering on thin films due to ionic implantations F. C. Ceoni, M. A. Rizzutto, M. H. Tabacniks, N. Added, M. A. P. Carmignotto, C.C.P. Nunes,
Y. Ueda, M. Fukumoto, H. Kashiwagi, Y. Ohtsuka (Osaka University)
XPS and SIMS MSN 506 Notes.
X-Ray Photoelectron Spectroscopy (XPS)
X-Ray Photoelectron Spectroscopy (XPS)
Secondary Ion Mass Spectrometry Professor Paul K Chu.
Secondary Ion Mass Spectrometry Professor Paul K Chu.
MiniSIMS Secondary Ion Mass Spectrometer Dr Clive Jones Millbrook Instruments Limited Blackburn Technology Centre, England
An Introduction to SIMS and the MiniSIMS ToF © Millbrook Instruments Limited Blackburn, UK
Secondary Ion Mass Spectrometry (SIMS)
The Surface Analysis Laboratory Cutting and Sputtering: Getting to the Buried Interface John F Watts The Surface Analysis Laboratory Department of Mechanical.
Ion-Driven Permeation of Deuterium through Tungsten Motivation Permeation experiment Results Next steps A. V. Golubeva, M. Mayer, J. Roth.
PC4250 Secondary Ion Mass Spectrometry (SIMS). What is SIMS? SIMS is a surface analysis technique used to characterize the surface and sub-surface region.
Ion Beam Analysis Dolly Langa Physics Department, University of Pretoria, South Africa Blane Lomberg Physics Department, University of the Western Cape,
TOPIC D: SPECTROMETRY AND SPECTROSCOPY. Mass spectrometry is used to detect isotopes. mass spectrometer uses an ionizing beam of electrons to analyze.
Overview of coatings research and recent results at the University of Glasgow M. Abernathy, I. Martin, R. Bassiri, E. Chalkley, R. Nawrodt, M.M. Fejer,
Quantification Techniques Under Dynamic SIMS 1 Secondary Ion Mass Spectrometer Start-Up Project Overview Secondary Ion Mass Spectrometry Overview MiniSIMS:
Overview of Characterization Methodology Michael J. Kelley College of William & Mary and Jefferson Lab
Sputter deposition.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
1 A. Kitamura, H. Iwai, R. Nishio, R. Satoh, A. Taniike and Y. Furuyama Department of Environmental Energy Science, Graduate School of Science and Technology,
High Q R&D at JLab G. Ciovati, P. Dhakal, R. Geng, P. Kneisel, G. Myneni TTC Topical Meeting on CW SRF Cornell Univ., June 12 th -14 th, 2013.
日 期: 指導老師:林克默、黃文勇 學 生:陳 立 偉 1. Outline 1.Introduction 2.Experimental 3.Result and Discussion 4.Conclusion 2.
Characterization of nuclear transmutations by 638 nm laser beams ( ¹ ) STMicroelectronics, via Tolomeo, Cornaredo Milano-I ( ² ) Applied Electronics.
31 May 2006Update ageing measurements at NIKHEF - LHCb week - Niels Tuning 1/37 Update ageing measurements at NIKHEF 31 May 2006 Niels Tuning, Gras van.
The effect of displacement damage on deuterium retention in plasma-exposed tungsten W.R.Wampler, Sandia National Laboratories, Albuquerque, NM R. Doerner.
Basics of Ion Beam Analysis
X-ray absorption spectroscopy (XAS)
N. Tabet (a), M. Faiz (a), N. M. Hamdan (b) and Z. Hussain (c) (a)Surface Science Laboratory, Physics.
Updates of Iowa State University S. Dumpala, S. Broderick and K. Rajan Sep – 18, 2013.
Ion Beam Analysis of the Composition and Structure of Thin Films
High Resolution Depth Profiling of Ti Oxidation
Rutherford Backscattering Spectrometry (RBS)
SRF Niobium Characterization Using SIMS and FIB-TEM Fred A. Stevie Analytical Instrumentation Facility North Carolina State University Raleigh, North Carolina.
REFERENCE [1] : Jin-Woo Han, Beomseok Kim, Nobuhiko P. Kobayashi, Jing Li, and M. Meyyappan, a simple method for the determination of doping type in nanomaterials.
Questions/Problems on SEM microcharacterization Explain why Field Emission Gun (FEG) SEM is preferred in SEM? How is a contrast generated in an SEM? What.
ALCPG2011, 3/19- 23, SRF Group Institute of Heavy Ion Physics, Peking University ALCPG /3/19-23, Eugene, Oregon, USA RF superconducting Cavity.
Lecture 5: Secondary ion mass spectroscopy (SIMS) Assoc. Prof. Dr. Zainovia Lockman, PPKBSM, USM EBB 245. Materials Characterisation.
High Temperature Heat Treatment to Raise the Quality Factor of Large Grain Niobium Cavities Pashupati Dhakal Gianluigi Ciovati Ganapati Rao Myneni July.
Scanning Tunneling Microscopy Studies of Single-Crystal Niobium Oxidation Natalie A. Kautz, Yichen Yu, Kevin D. Gibson.
Date of download: 5/31/2016 Copyright © ASME. All rights reserved. From: Influence of Interfacial Mixing on Thermal Boundary Conductance Across a Chromium/Silicon.
Atomic-scale characterization of Nb for SRF cavities using UV
LEAP investigation of hydrogen in SRF Niobium 7 th SRF Materials Workshop, JLAB Newport News, VA July 17, 2012 Yoon-Jun Kim and David N. Seidman Department.
The Applied Superconductivity Center The National High Magnetic Field Laboratory Florida State University 7 th SRF MW Investigation: Variation of Surface.
Study of some gilded film/glass interfaces and of one standard type of “liquid gold” XVI ICF TECHNICAL EXCHANGE CONFERENCE 9 th -12 th October 2004 Karlovy.
Niobium RRR and Ta specifications for SRF cavities: a critical review G. Ciovati, P. Kneisel and G. Myneni 7 th SRF Materials Workshop, July 16 th 2012.
Hiden Compact SIMS Mass Spectrometry in solid material.
Surface Resistance of a bulk-like Nb Film Sarah Aull, Anne-Marie Valente-Feliciano, Tobias Junginger and Jens Knobloch.
EOS Elettronica Organica per Strumentazione Innovativa di Ricerca.
New Cavity Techniques and Future Prospects
JLab infusion and LG flux expulsion update
Experiments at LCLS wavelength: 0.62 nm (2 keV)
High Q via N infusion R&D at Jefferson Lab
What is XPS? XPS (x-ray photoelectron spectroscopy) is also known as ESCA (electron spectroscopy for chemical analysis). XPS provides chemical information.
Study of vacuum stability at cryogenic temperature
Fermi Level Dependent Diffusion in Silicon
Dr. John S. Hammond Physical Electronics Chanhassen, MN, USA
文献 岳仑仑.
SRF Surface Studies and the High Field Q-slope Mystery
Determining Composition through X-Ray Photoelectron Spectroscopy
Sachiko Amari Washington University St. Louis MO, USA
JLab Work on Low Temperature Near-Surface Diffusion aka “Infusion”
Ion Beam Analysis (IBA)
Presentation transcript:

1 SIMS Characterization of Impurity Elements in Nb: The Effect of Heat Treatments ncsu.edu/aif jlab.org 1 P. Maheshwari, F. Stevie, D. Griffis, M. Rigsbee North Carolina State University G. Myneni, G. Ciovati Jefferson Laboratory

2 ncsu.edu/aif jlab.org 2 Large grain sample Secondary Ion Mass Spectrometry (SIMS) Escape depth of sputtered species only few Angstroms All elements and isotopes measurable (including H) ppm to ppb detection limit nm depth resolution typical, 1-2nm at low energies R. G. Wilson, F. A. Stevie, C. W. Magee: Secondary Ion Mass Spectrometry, Wiley-Interscience (1989)

3 ncsu.edu/aif jlab.org 3 1. Effect of High Temperature HT 800 o C/3hrs, 120 o C/12hrs 1200 o C/6hrs 800 o C/3hrs, 400 o C/20min Control H levels decrease up to a factor of 100, believed to be responsible for improvement in Q o (~45% at 90 mT, 2.0 K, 1.5 GHz); Insignificant changes in O, C and N levels

4 ncsu.edu/aif jlab.org 4 No heat treatment (Control) Intense hydride peaks observed in the mass spectra of a non heat treated sample; greatly reduced after high temperature heat treatment After 800 o C/3hrs, 400 o C /20min heat treatment SIMS measurements at 14.5 keV impact energy with Cs + NbH 5 - NbH 4 - NbH 3 - NbH 2 - Nb - NbH - Nb - NbH 2 - NbH - 1. Effect of High Temperature on Nb Hydrides

5 ncsu.edu/aif jlab.org 5 2. Effect of Baking Some change in H, Some diffusion of O in Nb (first 60nm), Reduction in Q-drop might be related to impurities? SIMS Analysis 6 keV Cs + (Low Energy) 120 o C/48hrs Control O Concentration after 120 o C/48 hrs HT H Levels after 120 o C/48 hrs HT H - /Nb - Ratio 120 o C/48hrs Control

6 ncsu.edu/aif jlab.org 6 3. O and Ti diffusion in Nb for HT >1000 o C O diffuses to the surface of Nb above 1000 o C in the presence of Ti Conc. (atoms/cm 3 ) 1400 o C/3hrs 1200 o C/2hrs,120 o C/12hrs O concentration in Nb Conc. (atoms/cm 3 ) 1400 o C/3hrs 1200 o C/2hrs,120 o C/12hrs Ti concentration in Nb SIMS measurements: 14.5 keV impact energy with Cs + SIMS measurements: 5.5 keV impact energy with O 2 +

7 4. Impurities in Grain Boundaries of LG Nb No segregation of H at grain boundary Segregation of C at grain boundary Grain Boundary of Bicrystal TOF SIMS Analysis using 25 keV Bi 3+ after sputtering for 3 min with 10 keV Cs o C/3hrs, 120 o C/24hrs Control

8 ncsu.edu/aif jlab.org 8 5. Quantification of H in Nb using Nb 2 O 5 Oxide acts as a passivation layer on the Nb surface; anodization of a control sample used to create a layer, about 150nm in thickness D and H implanted into the oxide to create SIMS standards Peaks observed for H, D in Niobium Oxide H increases as Oxide-Nb interface reached D implanted to place peak at Nb oxide/Nb interface SIMS measurements at 6 keV impact energy with Cs + Oxide Substrate

9 ncsu.edu/aif jlab.org 9 5. Estimate of H in Nb SIMS measurements at 6 keV impact energy with Cs + Matrix signal similar in oxide and in Nb, can use RSF from oxide to quantify H in Nb H concentration estimated to be 2e22 atoms/cm 3 ≈ 37 % atomic H on a control Nb sample surface 2E22 at./cm 3 Since the Nb secondary ion intensity shows little change between oxide and substrate, an estimate of H in Nb can be made using the RSF derived by taking Niobium Oxide implant as standard

10 Low Energy SIMS Analysis 6 keV Cs + ; Ti : 1.25 keV O o C/3hrs,120 o C/12hrs SRF cavity had record Q 0 of 4.6  at 90 mT, 2.0 K, 1.5 GHz ( Yesterday’s talk by P. Dhakal ) H - /Nb - Ratio Control 1400 o C/3hrs,120 o C/12hrs H - /Nb - Ratio Conc. (at/cm 3 )

Corroborated by NRA Analysis Control 800 o C/2hrs, 120 o C/24hrs Courtesy : Pacific Northwest National Lab., USA

Conclusions H seen to influence cavity performance, cavity efficiency increases by an average of 40% after heat treatment, possibly due to the reduction of H. H concentrations of ~40 at.% in BCP-treated Nb samples have been estimated by SIMS. H depth profiling is limited by matrix effect and high diffusion rate C segregation at grain boundaries was found by TOF-SIMS after heat treatment at 800 °C Significant concentrations (> 1 at.%) of Ti,O and low H levels were found in sample heat treated at 1400 °C (cavity with record Q 0 )