1 HMPID Project Assembly & Tests of CsI QE monitors: VUV-scanner and ASSET Milestone: December 2002.

Slides:



Advertisements
Similar presentations
Good Practices of Fluorescence Spectroscopy
Advertisements

ExoMars UV Laser diode thermal vacuum test Alex Rousseau.
The HPD DETECTOR The HPD working principles The HPD production CLUE Experiment The TOM Project The TOM HPDs LAB/Mountain HPD Measurements Michele Giunta.
1 First observations on CsI -coated ThGEM in Trieste presented by Gabriele Giacomini phone meeting 06/08/2008.
Currently: 3 year ( ) NSF-supported UF/IAP collaborative project "Methods and Instruments for High-Precision Characterization of LIGO Optical Components"
S. Bricola, A. Menegolli, M. Prata, M.C. Prata, G.L. Raselli, M. Rossella, C. Vignoli INFN and University of Pavia - Via Bassi, 6 – Pavia – Italy.
OL 750 Measurement Systems
CAMERA MATERIALS TEST CHAMBER Jack Singal 9/17/08 LSST Camera Workshop Turbo pump Optics table scroll pump and LN trap (for roughing A1, A3, and LL)
Large Multilayer Diffraction Gratings: Coating Uniformity Senior Student: Erik Krous Project Advisor: Dr. Carmen Menoni Collaborators: Dr. D. Patel, Dr.
Spatial profiles of copper atom density in a Cu/Ne hollow cathode discharge P. Hartmann*, T.M. Adamowicz**, E. Stoffels and W.W. Stoffels, Department of.
Provides a means to align a pattern on a chip to the pattern on a mask; and then to expose this pattern UV-light Mask: quartz + Cr pattern Photoresist.
CCD testing Enver Alagoz 12 April CCD testing goals CCD testing is to learn how to – do dark noise characterization – do gain measurements – determine.
Update on Armor Simulation Experiments At Dragonfire Facility Farrokh Najmabadi, John Pulsifer, Mark Tillack HAPL Meeting August 8-9, 2006 General Atomic.
HBD Transmission Monitor: Update on Assembly & Testing HBD Working Group Meeting 8/29/06 B. Azmoun Brookhaven National Lab.
CsI Photocathode Production and Testing
Thin films technology for RICH detectors Functionality Production technologies Performance Presented at the CBM-RICH workshop March 2006 André Braem,
Threshold ionization mass spectroscopy of radicals in RF silane discharge Peter Horvath 5/19/2004 Progress of experiments.
Corner Raft Test Station Kirk Arndt, Ian Shipsey Purdue University LSST Camera Workshop SLAC Sept , 2008.
Designer and Manufacturer of Scientific Instruments Since 1985.
Heavy Gas Cherenkov Mirror Reflectivity Measurement Hall C Workshop. August 27, Wenliang Li, Garth Huber, Keith Blackburn, Chris Gould, Joe Gubeli,
1 First observations on CsI -coated ThGEM in Trieste presented by Gabriele Giacomini phone meeting 06/08/2008.
Polarized GaAs photo cathode development and the preparation of Gatling Gun cathodes at BNL The Single Cathode Activation Chamber.
Tests WLS - Readout axial PET - Bari - Janvier 2007 AXIAL PET - HPD AXIAL COORDINATE RECONSTRUCTION WITH WLS STRIPS
Gas measurements and CsI photocathode studies at WIS Ilia Ravinovich November 2002 Weizmann Institute.
SAXS/WAXS Conversion for Beamline Engineering Review.
What we did up to now: Summary of the measurements performed up to now with the gas setup built for the THGEMs coated with the CsI. Photocurrent measurements.
HBD Gas and QE Monitoring Craig Woody BNL HBD Working Group Meeting October 19, 2005.
1 LAPPD Team meeting 6/10/2010 Ossy Siegmund, Experimental Astrophysics Group, Space Sciences Laboratory, U. California at Berkeley Bialkali Photocathode.
CBM-RICH: Photodetector developement CBM Collaboration Meeting February 2008 P.Koczoń, C.Höhne, A.Braem C.Joram, S.Ilie, M. van Stenis CBM Workshop February.
HBD CDR Gas System and Monitoring Craig Woody BNL DC Upgrades/EC Meeting March 9, 2005.
Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)
1 Status of Vacuum Process Facilities at SSL 16 October 2009 Sharon R Jelinsky Space Sciences Laboratory, UC Berkeley.
Laboratoire de Chimie-Physique CNRS – Université Paris-Sud UMR ORSAY Cs 2 Te photocathodes at ELYSE.
Ageing of large CsI photocathodes exposed to ionizing radiation in a gaseous RICH detector A. Braem, G. De Cataldo, A. Di Mauro, A. Franco, A. Gallas Torreira,
Itzhak Tserruya RICH 2004, Playa del Carmen 1 RICH 2004 Playa del Carmen, Mexico Nov. 30 – Dec. 5, 2004 Itzhak Tserruya Short report from RICH 2004 at.
LASER FRAME: Straightness monitor (Tentative results of resolution test) Third Mini-Workshop on Nano Project at ATF May 30-31,2005 KEK Nano BPM Group Y.Higashi,
IFS prototype – PM3 LAM, 13/06/2003 Prototype testing at CRAL Tests at room temperature in the visible.
Chamber Quality Control Before the construction several checks are performed on:  Panels (cathode and pad PCB)  GEM foil Tests on assembled detector.
HBD Gas System and Monitoring Craig Woody BNL HBD Working Group Meeting December 8, 2004.
BL SAXS End Station (Small Angle X-ray Scattering)
Schematic of Laser Transport Vacuum enclosure Laser Room Interlocked, controlled area Laser Wall Periscope in vacuum enclosure Cathode Fiduciary Beam line.
Real-time Ellipsometry on Cesium-Telluride Photocathode Formation
Quality-evaluation of Cesium Iodide photocathodes for the ALICE/High Momentum Particle Identification detector by means of a VUV-Scanner system Herbert.
1/26 WSHQE–October 4-6, 2006 L. Monaco INFN Milano – LASA Photocathode FLASH: Quantum Efficiency (QE) L. Monaco Work supported by the European.
F. Peauger19th June #3-CTF3 Committee1 CALIFES STATUS CA.BHB 0400CA.SNH 0110CA.SNI 0120 CA.VVS 0100 CA.DHG/DVG 0130 CA.VVS 0200 CA.MTV 0215 CA.BPM.
Sasha GilevichDrive Laser Meeting December Launch System Outline General Layout Incidence Angle Effect of the broad bandwidth.
Update on HBD Activities at BNL Craig Woody BNL HBD Working Group Meeting November 16, 2004.
Liquid Argon Purity Monitor Testing Bonnie Weiberg TRAC Program Summer, 2015 ICARUS clone made at FNAL (S. Pordes - FNAL May 13th 2006)
Pulsed Laser Deposition and Quantum Efficency of Mg films University of Lecce L. Cultrera.
New single-chip “box” to test laser soldering in vacuum WP6 meeting, 16/01/14.
Thin films technology for RICH detectors
Date of download: 10/12/2017 Copyright © ASME. All rights reserved.
Drive-Laser Commissioning Status and Plans
Detector development for
Laser Physics & Nonlinear Optics
Chapter 13 Chapter 13 Chapter 13 Chapter 13 Chapter 13 Chapter 13
Performances of the NA62 RICH detector
Cesium Telluride Photocathode Preparation at Argonne
Production of Cesium Iodide Photocathodes for
Chapter 3. Components of Optical Instruments
Detector development for
First observations on CsI-coated ThGEM in Trieste - ADDENDUM -
UCB Bialkali Cathode Process Program
Bialkali Cathode Process Program
Status of Cathode System in FZR
Bialkali Cathode Process Program
Instrumentation for UV and visible absorption
Injector Drive Laser Technical Status
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
Basic Operational Instructions
Presentation transcript:

1 HMPID Project Assembly & Tests of CsI QE monitors: VUV-scanner and ASSET Milestone: December 2002

2 VUV Scanner System for “in-situ” quality control of large area CsI photocathodes (PCs) immediately after the deposition: scanning measurement of the photocurrent produced illuminating PCs with a collimated light beam from a VUV deuterium source;  concept, design, drawings, production: done  assembly & tests: done ASSET ( “A Small Sample Evaporation and Test facility”) R&D setup: Characterization of small samples of CsI films  absolute QE evaluation with a VUV monochromator of resolution of ~4 nm. The monochromator system was designed to be compatible with the UV-system of the VUV- scanner (i.e. allow both UV-systems to be interchangeable): done  assembly and tests: done

3  Layout of the CERN/HMPID CsI deposition plant & VUV scanner  Monitoring: - RGA - Temperatures - Pressures - CsI deposition rates - Witness samples - VUV scanner (rel. QE)

4 Pad cathode mounted on rails Protective box 4 CsI sources (in series) VUV scanner mounted on rails Reference PM Auto CAD drawings:

5 (relative Quantum Efficiency determination) Production/assembly/tests 

6 Turbo pump Primary vac.pump PicoAmmeterMultiplexer D 2 -lamp Optics Before … Now: Inside evaporator  All scanning motions and photo-current readout-electronics are equipped with a remote control (NIDAQ/LabView)

7 VUV Scanner platform inside: Vacuum feed through (4x) Ref.PM & housing Anode ring & Cathode ring & gnd shield PC ‘trolley Rotating Mirror Vertical alignment of Ref.PM and anode Horizontal alignment of mirror and anode

8 Tests, e.g.: - remote control X,Y motion (scan), - PicoAmp.-readout - incident UV-spot scan with photo-diode Optical alignment with laser (e.g. red spot)

9 P < mbar 4 interferential filters on rotary disk: relative QE Ref.PM (CsTe) UV source sample holder for 2 samples (18x18mm 2 ) anode grid picoAm.1 picoAm.2 ASSET: A Small Sample Evaporation and Test facility Previous layout/concept: relative QE determination  implicit test for VUV-scanner application: OK evaporation chamber UV test chamber S1S2 UV light spot of   5mm ASSET upgrade with UV-monochromator: absolute QE measurements 

10 UV-mirror Sample holder input Argon output Argon MgF 2 lens & x-y micro-control lens holder diaphragm anode grid Ref PM UV test chamber Deuterium lamp with quartz exit-window Upgrade concept & design (compatible with VUVscanner optics) monochromator box (leak- & light-tight)

11 System test: Deuterium Lamp spectrum D 2 -peak at =160 nm is being cut off by the quartz exit window of the D 2 -lamp I [pA] [nm] Upgraded setup is ready