James A Germann, Brian K Canfield, Jason K King, Alexander Terekhov, Lloyd M Davis.

Slides:



Advertisements
Similar presentations
Detection volume in confocal microscopy:
Advertisements

RICS Simulations for two photon excitation. Opening page of GLOBALS for Images program: Click on the SimFCS buttom.
R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.
Instructor: Lichuan Gui
Fluorescence lifetime correlation spectroscopy A cross-talk free dual color fluorescence cross correlation spectroscopy Dual-Color Fluorescence Lifetime.
Optical Tweezers F scatt F grad 1. Velocity autocorrelation function from the Langevin model kinetic property property of equilibrium fluctuations For.
Short pulses in optical microscopy Ivan Scheblykin, Chemical Physics, LU Outline: Introduction to traditional optical microscopy based on single photon.
Micro PIV  An optical diagnostic technique for microfluidics (e.g. MEMS, biological tissues, inkjet printer head) Requirements: Measure instantaneously.
OPT OPT 253 Quantum Optics Laboratory, Final Presentation Wednesday, December 10 th 2008 By Carlin Gettliffe.
Thermo-elastic properties characterization by photothermal microscopy J.Jumel,F.Taillade and F.Lepoutre Eur. Phys. J. AP 23, Journal Club Presentation.
Development of Experiment for Materials Studies at the Z-Beamlet Laser Facility Lasers enable us to study the state of materials and the dynamics of material.
Optical trapping of quantum dots in air and helium gas KAWAI Ryoichi Ashida Lab. 2013/10/30 M1 colloquium.
Two vertical-cavity surface-emitting lasers (VCSEL’s) are used at Alice, as sources of the two encoded states. Both outputs are then attenuated to achieve.
Particle Image Velocimetry (PIV) Introduction
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Dr Gihan Gawish Hydrodynamic focusing is a technique used to provide more accurate results from flow cytometers or Coulter counters for determining the.
Two-Focus Fluorescence Correlation  Spectroscopy: A New Tool for Accurate and Absolute Diffusion Measurements Jörg Enderlein et al., ChemPhysChem, 8, 433–443.
Peter J. LaPuma1 © 1998 BRUKER AXS, Inc. All Rights Reserved This is powder diffraction!
Sowmya Vasa, Umar Alqasemi, Aditya Bhargava. Objectives This paper aims in bringing out a novel light microscopy method called Focal Modulation Microscopy.
FCS Club Sept 8 th 2006 Schwille, P., F. Meyer-Almes and R. Rigler (1997). "Dual-color fluorescence cross- correlation spectroscopy for multicomponent.
Interference Total Internal Reflection Microscopy Particle 2D-tracking with high spatial and temporal resolution x.
Pursuing the initial stages of crystal growth using dynamic light scattering (DLS) and fluorescence correlation spectroscopy (FCS) Takashi Sugiyama Miyasaka.
Fluorescence Correlation Spectroscopy
Measurements in Fluid Mechanics 058:180 (ME:5180) Time & Location: 2:30P - 3:20P MWF 3315 SC Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor: Lichuan.
Doppler Free LASER Spectroscopy
M. J. Levene, W.W. Webb et al. Science (2003).
Optics Focus Confocal theory.
Diffusion of CaM and CaMK-II Andrew Harrell Dr. Waxham Lab University of Texas Medical School.
Tracking and Probing Single, Diffusing Molecules in Droplets Mark Arsenault, Peker Milas, Ben Gamari, Richard Buckman, Lori Goldner Biophysics Group MiniSymposium.
10-meter Interferometer Results M. Woods (special thanks to Steve Myers and Tim Slaton) Jan. 31, 2000 Commissioning Setup System Noise Monte Carlo simulation.
Date of download: 6/25/2016 Copyright © 2016 SPIE. All rights reserved. Schematic optical layout of the instrument. Color box legend: Upright optical tweezers.
Date of download: 7/8/2016 Copyright © 2016 SPIE. All rights reserved. Through-the-objective TIRF creates the evanescent field on the aqueous side of the.
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. (a) z-scan of the PTLS signal calculated in the mode-matched configuration for different.
Date of download: 9/19/2016 Copyright © 2016 SPIE. All rights reserved. Schematics of the 3-D printed probe for tissue collagen differentiation. (a) The.
Flowcytometry.
Jason K. King, Brian K. Canfield, Lloyd M. Davis and William H
Picosecond Multiphoton Scanning Near-Field Optical Microscopy
Supported by NIH Grant EB
Volume 91, Issue 8, Pages (October 2006)
Volume 84, Issue 6, Pages (June 2003)
Kevin T. Takasaki, Jun B. Ding, Bernardo L. Sabatini 
K-Space Image Correlation Spectroscopy: A Method for Accurate Transport Measurements Independent of Fluorophore Photophysics  David L. Kolin, David Ronis,
Measurement of Single Macromolecule Orientation by Total Internal Reflection Fluorescence Polarization Microscopy  Joseph N. Forkey, Margot E. Quinlan,
Helmut J. Koester, Dagmar Baur, Rainer Uhl, Stefan W. Hell 
Molecular Dynamics in Living Cells Observed by Fluorescence Correlation Spectroscopy with One- and Two-Photon Excitation  Petra Schwille, Ulrich Haupts,
Analysis of Optical Beam Propagation Through Turbulence
Volume 90, Issue 8, Pages (April 2006)
The Mobility of Phytochrome within Protonemal Tip Cells of the Moss Ceratodon purpureus, Monitored by Fluorescence Correlation Spectroscopy  Guido Böse,
Volume 83, Issue 6, Pages (December 2002)
Volume 99, Issue 8, Pages (October 2010)
High-Throughput Nonlinear Optical Microscopy
Volume 110, Issue 4, Pages (February 2016)
Sapun H. Parekh, Young Jong Lee, Khaled A. Aamer, Marcus T. Cicerone 
Volume 88, Issue 4, Pages (April 2005)
Cylindrical Illumination Confocal Spectroscopy: Rectifying the Limitations of Confocal Single Molecule Spectroscopy through One-Dimensional Beam Shaping 
Volume 90, Issue 8, Pages (April 2006)
Francesca Pennacchietti, Travis J. Gould, Samuel T. Hess 
Volume 95, Issue 1, Pages (July 2008)
Kinesin Moving through the Spotlight: Single-Motor Fluorescence Microscopy with Submillisecond Time Resolution  Sander Verbrugge, Lukas C. Kapitein, Erwin.
Volume 104, Issue 1, Pages (January 2013)
Pulsed Interleaved Excitation
The Standard Deviation in Fluorescence Correlation Spectroscopy
Samuel T. Hess, Watt W. Webb  Biophysical Journal 
Volume 88, Issue 6, Pages (June 2005)
Volume 95, Issue 11, Pages (December 2008)
Characterization of the Photoconversion on Reaction of the Fluorescent Protein Kaede on the Single-Molecule Level  P.S. Dittrich, S.P. Schäfer, P. Schwille 
Translational Diffusion of Fluorescent Proteins by Molecular Fourier Imaging Correlation Spectroscopy  Michael C. Fink, Kenneth V. Adair, Marina G. Guenza,
High-Pressure Fluorescence Correlation Spectroscopy
Volume 98, Issue 1, Pages (January 2010)
The Mobility of Phytochrome within Protonemal Tip Cells of the Moss Ceratodon purpureus, Monitored by Fluorescence Correlation Spectroscopy  Guido Böse,
Presentation transcript:

James A Germann, Brian K Canfield, Jason K King, Alexander Terekhov, Lloyd M Davis

 Fluorescence Correlation Spectroscopy (FCS) - analysis of time-dependent fluorescence fluctuations  Fluorescence Cross Correlation Spectroscopy – FCS between more than one volume  Correlation functions measure diffusion and velocity through solution  Schwille, P., F.J. MeyerAlmes, and R. Rigler, Biophysical Journal, (4): p  Webb, W.W., Applied Optics, (24): p Photon at time t

y x z x y  Four foci in a tetrahedral configuration  Separation of foci provide a standard ruler for flow measurements  Collect four autocorrelation curves and twelve cross- correlation curves (three cross- correlations for each focus)

 Advantages Naturally depth selective Low background Large difference between excitation and fluorescence wavelengths  Disadvantages Higher laser power Requires pulsed laser line Single-Photon Two-Photon

m5 m3 bs2 laser beam input Ti:Sapphire pulses, 76MHz A B 1 2 m1 m2 50% Beamsplitter bs1 bs3 m4 Four paths: A1 = shortest A2 = A ns B1 = A ns B2 = A ns Microscope objective Four-beam alignment

m5 m3 bs2 laser beam input Ti:Sapphire pulses, 76MHz AB m1 m2 50% Beamsplitter bs1 bs3 m4   A1,B2 displaced ↑  Microscope objective 1 2 Four paths: A1 = shortest A2 = A ns B1 = A ns B2 = A ns  Four-beam alignment

 m5 m3 bs2 laser beam input Ti:Sapphire pulses, 76MHz A B Microscope objective m1 m2 50% Beamsplitter bs1 bs3 m4   (out of plane)   A1,B2 displaced ↑ A2,B2 displaced →  1 2 Four paths: A1 = shortest A2 = A ns B1 = A ns B2 = A ns  Four-beam alignment

m5 m3 bs2 laser beam input Ti:Sapphire pulses, 76MHz A B m1 m2 50% Beamsplitter bs1 bs3 m4   (out of plane)    A1,B2 displaced ↑ A2,B2 displaced → B1,B2 focused   1 2 Four paths: A1 = shortest A2 = A ns B1 = A ns B2 = A ns   Microscope objective Four-beam alignment

Photodiode 532 nm diode laser (alignment) Ti-Sapphire beam

removable mirror piezo stage pinhole lens mirror Dichroic Mirror SPAD

A1 A2 B1B2A1A2B1B2 No crosstalk Crosstalk

 Rhodamine B pumped through capillary  One-dimensional flow  Flow velocity dependent on bulk flow rate, cross-sectional area, and distance from capillary walls -T. S. Lundgren J. Basic Eng 86: , 1964

 Laminar flow created along the optical axis with crossed channel microfluidics  Microfluidics created by etching a channel on two coverslips and bonded via fusion bonding  Sample fluid driven through the microfluidic at a constant speed. Two crossed microchannels for 4-beam 3-D trapping

 Simulated fluorescing particles moving through four foci  Fluorescence photons sorted based on time of counting  Correlation curves created from photon statistics  Three-dimensional Gaussian model applied to correlation functions  Flow velocities globally fit

 Three-dimensional Gaussian is not accurate enough.  New model using Gaussian-Lorentzian Simulation Parameters Vx=1 mm/s Vy= 2mm/s Vz=3 mm/s Fit Parameters Vx=.66 mm/s Vy=1.41 mm/s Vz=2.13 mm/s

 FCCS performed in three-dimensions simultaneously  Four temporally and spatially distinct foci created using a Mach-Zehnder interferometer configuration  Fluorescence separated with time-gated photon counting  Calibration experiments with square bore capillary  Three-dimensional flow created with cross- channel device  Flow simulated with Monte Carlo simulations