Rita Carbone, RICAP 11, Roma 3 26/05/2011 Stand-alone low energy measurements of light nuclei from PAMELA Time-of-Flight system. Rita Carbone INFN Napoli.

Slides:



Advertisements
Similar presentations
ATLAS Tile Calorimeter Performance Henric Wilkens (CERN), on behalf of the ATLAS collaboration.
Advertisements

ELENA VANNUCCINI ON BEHALF OF PAMELA COLLABORATION Measurement of the Hydrogen and Helium absolute fluxes with the PAMELA experiment.
E. Mocchiutti, INFN Trieste - CALOR th June 2006, Chicago E. Mocchiutti 1, M. Albi 1, M. Boezio 1, V. Bonvicini 1, J. Lund 2, J. Lundquist 1, M.
INTRODUCTION TO e/ ɣ IN ATLAS In order to acquire the full physics potential of the LHC, the ATLAS electromagnetic calorimeter must be able to identify.
PAMELA Payload for Antimatter Matter Exploration and Light Nuclei Astrophysics.
March 13thXXXXth RENCONTRES DE MORIOND 1 The Alpha Magnetic Spectrometer on the International Space Station Carmen Palomares CIEMAT (Madrid) On behalf.
Performance of AMS-02 on the International Space Station DESY Theory Workshop, Hamburg Melanie Heil Supported by the Carl-Zeiss Foundation.
GLAST LAT Project Calibration & Analysis Meeting - August 29, 2005 Benoît Lott Gamma-ray Large Area Space Telescope Response of the GLAST LAT Calorimeter.
Davide Vitè - MInstPhys CPhys Particle Physics 2000, Edimburgh, 12 April AMS the Anti-Matter Spectrometer n The past:10 days on Discovery n The.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
Timing Properties of T0 Detectors At PHOBOS Saba Zuberi, Erik Johnson, Nazim Khan, Frank Wolfs, Wojtek Skulski University of Rochester.
The Time-of-Flight system of the PAMELA experiment: in-flight performances. Rita Carbone INFN and University of Napoli RICAP ’07, Rome,
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
PAMELA – a satellite experiment searching for dark matter with cosmic ray antiparticles Mark Pearce KTH, Department of Physics, Stockholm, Sweden For the.
A scintillation detector for neutrons below 1 MeV with gamma-ray rejection Scintillators are 3 mm BC408, 10 layers total Adjacent layers are optically.
Fast Simulation of TOF Response A.Galoyan, LPP, JINR, Dubna Used model.
Roberta Sparvoli University of Rome “Tor Vergata” and INFN Rome, Italy
Lake Louise - February Detection & Measurement of gamma rays in the AMS-02 Detector J. Bolmont - LPTA - IN2P3/CNRS Montpellier - France.
Lake Louise Winter Institute, 23rd February, Cosmic Ray Velocity and Electric Charge Measurements in the AMS experiment Luísa Arruda on behalf of.
Roberta Sparvoli Roberta Sparvoli for the PAMELA Collaboration University of Rome Tor Vergata and INFN Roma II, Italy Uuuuuu Uuuu uuuuuuu.
PrimEx collaboration meeting Energy calibration of the Hall B bremsstrahlung tagging system using magnetic pair spectrometer S. Stepanyan (JLAB)
The PAMELA Experiment: Preliminary Results after Two Years of Data Taking Emiliano Mocchiutti - INFN Trieste on behalf of the PAMELA Collaboration.
COSMIC RAY PHYSICS WITH AMS Joseph Burger MIT On behalf of the AMS-02 collaboration EPS2003 Aachen Particle Astrophysics July 17, 2003
1 Energy loss correction for a crystal calorimeter He Miao Institute of High Energy Physics Beijing, P.R.China.
Simonetta Gentile Rencontres du Vietnam,Hanoi 2004 Cosmic Ray Physics with the Alpha Magnetic Spectrometer Simonetta Gentile Università di Roma La Sapienza,
Trapped positrons and electrons observed by PAMELA Vladimir Mikhailov NRNU MEPHI, Moscow, Russia For PAMELA collaboration ICPPA 2015, PAMELA workshop,
Observation of light nuclei with PAMELA Roberta Sparvoli Laura Marcelli, Valeria Malvezzi, Cristian De Santis and the PAMELA Collaboration.
The Alpha Magnetic Spectrometer (AMS) on the International Space Station (ISS) Maria Ionica I.N.F.N. Perugia International School.
Measurements of Cosmic-Ray Helium, Lithium and Beryllium Isotopes with the PAMELA- Experiment Wolfgang Menn University of Siegen On behalf of the PAMELA.
H, He, Li and Be Isotopes in the PAMELA-Experiment Wolfgang Menn University of Siegen On behalf of the PAMELA collaboration International Conference on.
Calo preparation for 2015 Goals: -Trigger stability -Good calibration for HLT2 processing -Improved calibration ( timing, e/gamma response) for all calo.
Particle Identification. Particle identification: an important task for nuclear and particle physics Usually it requires the combination of informations.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
High-energy Electron Spectrum From PPB-BETS Experiment In Antarctica Kenji Yoshida 1, Shoji Torii 2 on behalf of the PPB-BETS collaboration 1 Shibaura.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
Feb. 3, 2007IFC meeting1 Beam test report Ph. Bruel on behalf of the beam test working group Gamma-ray Large Area Space Telescope.
Photon Transport Monte Carlo September 27, 2004 Matthew Jones/Riei IshizikiPurdue University Overview Physical processes PMT and electronics response Some.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Monte Carlo simulation of the particle identification (PID) system of the Muon Ionization Cooling Experiment (MICE) Mice is mainly an accelerator physics.
ISCRA – Erice July 2004 Ana Sofía Torrentó Coello - CIEMAT THE AMS EXPERIMENT Ana Sofía Torrentó Coello – CIEMAT (Spain) On behalf of AMS Collaboration.
DAMPE: now in orbit G. Ambrosi – DAMPE coll.. DAMPE: now in orbit G. Ambrosi – DAMPE coll.
The high-energy antiproton-to-proton flux ratio with the PAMELA experiment Massimo Bongi INFN - Florence Payload for Antimatter/Matter Exploration and.
1 A. Zech, Instrumentation in High Energy Astrophysics Chapter 6.2: space based cosmic ray experiments.
Idee per lo sviluppo del Charge Identifier
The Transition Radiation Detector for the PAMELA Experiment
DAMPE: first data from space
Comparison of GAMMA-400 and Fermi-LAT telescopes
Imaging Dark Matter with the Pamela Experiment
Event Reconstruction and Data Analysis in R3BRoot Framework
CALET-CALによる ガンマ線観測初期解析
GPAMELA Alessandro Bruno.
Cosmic-Rays Astrophysics with AMS-02
The magnetic spectrometer of PAMELA
Secondary positrons and electrons measured by PAMELA experiment
Cosmic-Ray Lithium and Beryllium Isotopes in the PAMELA-Experiment
Measurements of Cosmic-Ray Lithium and Beryllium Isotopes
for the PAMELA collaboration
Chris Smith California Institute of Technology EPS Conference 2003
Gamma-ray Large Area Space Telescope
NUCLEUS-NUCLEUS COLLISION Centrality Determination For NICA/MPD
Results from the PAMELA space experiment
Calorimetry in space with PAMELA
Plans for checking hadronic energy
Recent results on antiparticles in cosmic rays from PAMELA experiment
Imaging crystals with TKR
ACCELERATORS AND DETECTORS
BESIII TOF Digitization
The magnetic spectrometer of PAMELA
Presentation transcript:

Rita Carbone, RICAP 11, Roma 3 26/05/2011 Stand-alone low energy measurements of light nuclei from PAMELA Time-of-Flight system. Rita Carbone INFN Napoli On behalf of the PAMELA collaboration

The PAMELA mission Search for antimatter Search for dark matter Study of cosmic-ray propagation Study solar physics and solar modulation Study of electron spectrum Study terrestrial magnetosphere First switch-on on June 21th 2006 Continuous data taking mode since 11th July 2006 Mission extended till December 2011 Launched on June 15th 2006

PAMELA apparatus Main requirements: high-sensitivity particle identification, precise momentum measure. Time-Of-Flight plastic scintillator strips + PMT: plastic scintillator strips + PMT:  trigger, albedo rejection;  trigger, albedo rejection;  mass identification up to E ~ 1 GeV;  mass identification up to E ~ 1 GeV;  charge identification from dE/dX.  charge identification from dE/dX. Magnetic spectrometer with microstrip Si tracker: with microstrip Si tracker:  charge sign and momentum  charge sign and momentum from the curvature; from the curvature;  charge identification from dE/dX.  charge identification from dE/dX. Electromagnetic calorimeter W/Si sampling; 16.3 X0: W/Si sampling; 16.3 X0:  discrimination e + / p, e - / p -  discrimination e + / p, e - / p - from shower topology; from shower topology;  direct E measurement for e-.  direct E measurement for e-.  charge identification from dE/dX  charge identification from dE/dX

The Time-of-Flight system provide a fast signal for triggering data acquisition in the whole instrument provide a fast signal for triggering data acquisition in the whole instrument measure the flight time of particles crossing its planes; rejection of albedo particles measure the flight time of particles crossing its planes; once this information is integrated with the measurement of the trajectory length through the instrument, their velocity can be derived. This feature enable also the rejection of albedo particles determine the absolute value of charge z of incident particles determine the absolute value of charge z of incident particles through the multiple measurement of the specic energy loss dE/dx in the scintillator counters 6 layers (3 planes, double view) Several paddles (scintillator + 2 PMTs) for each layer

Single paddle time resolution The position of the hit point on a paddle as reconstructed by the ToF is proportional to the difference of the time measurements operated at both ends for that event Plotting this TOF position vs. the position as reconstructed by the Tracker (assuming negligible the uncertanty in the projected position), the σ of the distribution of residuals gives us the single paddle time resolution. Time measurements Measured time resolution is ~200 ps for S1 and S3 paddles and ~150 ps for S2 paddles for Z=1 particles Measured time resolution is ~200 ps for S1 and S3 paddles and ~150 ps for S2 paddles for Z=1 particles For higher Z the time resolution improves: for Z=2 it is ~105 ps, for Z=6 it is ~70 ps For higher Z the time resolution improves: for Z=2 it is ~105 ps, for Z=6 it is ~70 ps This results are in agreement with some results from a beam test of February 2006 (in this case time resolution reached a value of 48 ps for Carbon ions) This results are in agreement with some results from a beam test of February 2006 (in this case time resolution reached a value of 48 ps for Carbon ions) As a consequence, the resolution in measurements of time of flight is ~300 ps for Z=1 particles and improves to ~100 ps for Carbon events As a consequence, the resolution in measurements of time of flight is ~300 ps for Z=1 particles and improves to ~100 ps for Carbon events

β measurement time of flight and β are related by: So each single measurement of time of flight allows a β measurement, whose resolution is given by the relation: The 6 ToF layers of PAMELA allow up to 12 independent measurements of time of flight and β, significantly improving this resolution! Plotting distributions of 1/β for relativistic samples of different nuclei we observe that also β resolution improves with increasing Z: σ ~ 14% for protons σ ~5% for Carbon σ ~ 5% for Carbon

Particle identification with ToF dE/dx vs. β distribution in a paddle dE/dx vs. β distribution in a paddle (after corrections for attenuation, gain variation and non linearity ) scaling for a Bethe-Block function Z measured in a paddle

A useful application: a completely ToF stand-alone B/C ratio measurement S11 S12 S21 S22 S31 S32 Used for selection Used for efficiency calculation All analysis is based only on flight data recorded till 31 January 2010

A useful application: a completely ToF stand-alone B/C ratio measurement Kinetic energy per nucleon E can be derived event by event from β measurement according to the relation E=amu(γ-1). Kinetic energy per nucleon E can be derived event by event from β measurement according to the relation E=amu(γ-1). As a consequence of resolution in β measurements, such energy measurement is realiable up to 2.5 GeV/n As a consequence of resolution in β measurements, such energy measurement is realiable up to 2.5 GeV/n Such energy determination is independent of the isotopic composition Such energy determination is independent of the isotopic composition All other sub-detectors are used, for this work, only for cross-correlation purpose in the “calibration” phase All other sub-detectors are used, for this work, only for cross-correlation purpose in the “calibration” phase

Boron and Carbon selection good quality sample of nuclei candidates (rejection of albedo particles and multiple event, removing South Atlantic Anomaly, etc.) good quality sample of nuclei candidates (rejection of albedo particles and multiple event, removing South Atlantic Anomaly, etc.) Using cross-correlation between ToF and Calorimeter we can calculate functions Z=f(E) and σ=f(E) for each nucleus on each ToF layer Using cross-correlation between ToF and Calorimeter we can calculate functions Z=f(E) and σ=f(E) for each nucleus on each ToF layer ToF layers S12, S21 and S22 are used for nuclei identification: |Z S12 -Z C S12 (E)|<1σ C S12 (E) AND |Z S2 -Z C S2 (E)|<1σ C S2 (E) ToF layers S12, S21 and S22 are used for nuclei identification: |Z S12 -Z C S12 (E)|<1σ C S12 (E) AND |Z S2 -Z C S2 (E)|<1σ C S2 (E) ~ B and ~ C selected events ~ B and ~ C selected events

Selection efficiency Efficiency sample: Same “quality” cut as for the analysis sample; Same “quality” cut as for the analysis sample; Monochromatic sample of B and C selected by S11 and S3 layers: |Z S11 -Z C S11 (E)|<1σ C S11 (E) AND |Z S3 -Z C S3 (E)|<1σ C S3 (E) Monochromatic sample of B and C selected by S11 and S3 layers: |Z S11 -Z C S11 (E)|<1σ C S11 (E) AND |Z S3 -Z C S3 (E)|<1σ C S3 (E) The efficiency of the selection is very law at low energy values, expecially for Carbon, because of the early saturation of the S2 plane. Efficiency of C selection Log10(E)

Stand-alone ToF B/C ratio in energy range GeV/n AMS: Aguilar et al., Astrophys.J.724: (2010) HEAO: Engelmann et al., Astron.Astrophys. 233, (1990)

Spare

Charge calibration of the ToF Many difficulties during calibration because of: 6 different groups of scintillators + 48 different PMTs → 48 independent calibrations Loss of linearity of the instrument due to Birks’saturation of scintillators and loss of gain of PMTs at high values of charge deposits Timing and damaging effects A complex 4 step charge calibration to go from ADC to dE/dx: 1. ADC counts-pC conversion + attenuation of the signal along the paddle 2. Compensation of non-linearity for relativistic sample 3. Evaluation of Bethe-Bloch functions and compensation of non linearity also for non-relativistic sample 4. Corrections for time dependence and aging effect