Unit 209: Drainage systems

Slides:



Advertisements
Similar presentations
Typical Plumbing System
Advertisements

Unit 206: Domestic hot water systems
Waste Pipe from Bath The waste pipe from the bath should be a minimum of 40mm in diameter, it can be 50mm in diameter if there is a longer run of pipe.
Unit 206: Domestic hot water systems
Cold feed to hot water cylinder Sink Basin Bath Drain valve Stop valve WC cistern 100 litre (minimum storage cistern)
Household Waste Drainage Systems
Unit 205: Cold water systems
STUDOR ® STUDOR ® AUSTRALIA Presents The Introduction & Installation Course for the STUDOR ® Mini-Vent  Air Admittance Valve (AAV)
Objective of the session.
Mains Sewage Systems. Name: Padraig McMahon Module: Building services.
Understanding and Designing Plumbing Systems
Unit 206: Domestic hot water systems
Condensation Piping and Installation Drain Pans
Unit 205: Cold water systems
Trade of Plumbing – Phase 2 Module 2 – Unit 12 Module 2: Domestic Hot and Cold Water Services Unit 12 – Above Ground Sanitation Pipework Duration – 18.
How do each part of a W.C’s work? Don’t worry I will explain everything to you.
Outcome 2 Materials used to install domestic central heating pipework Unit 208: Central heating systems.
Unit 205: Cold water systems
Unit 206: Domestic hot water systems
Sanitary System. Function the SANITARY system handles waste water from wash basins, sinks, showers baths, galley equipment as well as waste water from.
Unit 206: Domestic hot water systems
Lesson One.
STUDOR® AUSTRALIA Presents
Rainwater Harvesting.
Presentation on Installation of a Domestic Cold Water Storage Cistern
Presentation on Trap Loss
Hydronic Mechanical Controls
Water © PDST Home Economics. Water cycle Water we use in our houses comes from rainfall which forms rivers or lakes or reservoirs, is then treated and.
Building drainage.
How to reduce water consumption and reduce costs
Facilities Management and Design Chapter 5 Water and Wastewater systems.
Unit 205: Cold water systems
Unit 208: Central heating systems
BUILDING MATERIAL BUILDING MATERIAL PALESTINE UNIVERSITY chapter No.#7 Mechanical Works Dr. Ali Ibrahim Tayeh.
NGfL CYMRU GCaD PLUMBING APPLIANCES & COMPONENTS.
Use & Re-use Water is used in a conventional way such as bathing or washing dishes, except for the toilet. The water is used and cleaned a second time.
Presentation on Feed and Expansion Cistern. Central Heating At the end of this part you should be able to: Identify general system methods of feed and.
TREATMENT PROCESS (Chicago)
Water Recycling. Why? Do you think water should be recycled? Why? How do you think water is recycled?
How do we harvest rainwater and why should we.. Why Harvest Rainwater? Decrease the volume of potable water used for irrigation. Recharge the groundwater.
HOT WATER Understand and apply domestic hot water system installation and maintenance techniques.
DOMESTIC DRAINAGE SYSTEM 2012BC25444
House Drainage System By- Prajyoti P. Upganlawar
Outcome 4 (part 4) Install and test above ground systems Unit 209: Drainage systems.
HOUSE DRAINAGE MEHTA ANJANI PRAFULBHAI =
Unit 209: Drainage systems
N ATIONAL D IPLOMA M ECHANICAL AND E LECTRICAL S ERVICES C ONSTRUCTION Drainage Design.
Unit 209: Drainage systems
National Diploma Mechanical and Electrical Services Construction Cold Water Supplies.
Resources Required : AS/NZ 3500 : Part 0 : 2003 Plumbing and drainage
Plumbing system fundamental and design course
Mahatma Gandhi Institute Of Technical Education & Research centre ,Navsari. A presentation on House Drainage Subject :- Environmental engineering.
Partially separate system
Pumped Discharge. Brian Makin 14/
Approximate activity space required
Heating Ventilation and Air Conditioning
RESIDENTIAL PLUMBING SYSTEMS (WASTEWATER)
What is an on-lot sewage system?
Outcome 1 (part 1) Types of domestic central heating systems installed in domestic dwellings Unit 208: Central heating systems.
Electrical Gas Plumbing Heating & Cooling
PLUMBING APPLIANCES & COMPONENTS
Typical Plumbing System
Hot water Systems Heaters.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Cold water supply and Treatment
Hot Water Systems Cylinders and Systems.
Cisterns and Insulation
2 Days National Workshop on “National Building Code of India 2016 ”
Inspection chamber - IC Inspection chamber - IC
Presentation transcript:

Unit 209: Drainage systems Outcome 1 (part 2) The requirements of drainage systems

Types of systems Secondary ventilated stack With this system, the main stack has a secondary vent, which is connected from just above the long radius bend going up to the dry section of the stack. This secondary vent allows additional airflow and safeguards against any positive or negative pressure fluctuations.

Types of systems Secondary ventilated stack

Types of systems Ventilated branch system This tends to only be used in larger systems where the risk of trap seal loss is high (public buildings, hotels, hospitals etc). Each branch is ventilated no more than 750mm from the appliance. This allows additional airflow, not only in the main stack but also in each discharge branch, which safeguards against any positive or negative pressure fluctuations.

Types of systems Ventilated branch system

Types of systems Ventilated branch system As shown in the illustration on the previous slide, the discharge branches migrate downwards allowing the effluent to discharge, while the branch ventilating pipes migrate upwards so no effluent can enter the vent system. The size of the branch ventilating pipe for a single appliance is a minimum of 25mm – for multiple appliances it is 32mm.

Types of systems Ventilated branch system Any branch ventilating pipe must be connected to the discharge stack above the spillover level of the appliance.

Types of systems

Types of systems Primary Secondary Ventilated ventilated ventilated discharge branch system system system

Types of systems Termination A soil stack can either terminate inside the loft area or ducting within the property, or it can terminate outside the property to atmosphere. In either case, no foul smell should be allowed to penetrate the property.

Types of systems Termination According to Building Regulations the acceptable way to terminate a soil stack inside a building is by installing an air admittance valve. This allows air in if the pressure fluctuates, but it does not allow foul air out.

Types of systems Termination The main purpose of an air admittance valve is to allow air into the stack but not to allow the foul air into the building. The AAV is sometimes situated inside boxing. If this is the case there must be: Access available for maintenance Sufficient ventilation in the boxing for the AAV

Types of systems Termination When installing an air admittance valve, the manufacturer’s instructions must be followed. Insulation against freezing is required. It must be installed at least 1 metre above the highest spillover level.

Types of systems Stub stack This allows appliances to be connected directly to the drain. Ventilation is only required when the highest appliance is above 2 metres, or the distance from the invert to floor level is greater than 1.3 metres. The ventilation can be acquired via an air admittance valve.

Types of systems Stub stack The maximum distance a stub stack can be installed away from the main vented stack (branch drain) is 6 metres. The vented stack must always be installed at the head or highest part of the run. 2.0m max to highest connection 1.3m max from invert to ground floor

Types of systems Termination The air admittance valve allows air into the stub stack, avoiding trap seal loss. As the appliance is discharging it sucks air into the stub stack, stabilising the pressure. Normally a stub stack is capped off with an access cap. Access cap Invert level 2.0m 1.3m

Types of systems Termination If the soil stack terminates outside the property and is installed within 3 metres of an opening window, the stack should be installed at least 900mm above the window.

Types of systems Termination A terminal fitting should be installed on the top of the soil stack to prevent any debris from falling down the stack and causing a blockage. If the installation is in a windy area, a vent cowl may need to be fitted.

Types of systems Termination When a vent pipe protrudes through a roof line it will need to be correctly weathered using: Lead or weathering slate: Weather collar: These will stop rainwater penetrating the property.

Types of systems Grey water recovery This is a type of recycling, which reuses the water from washbasins, showers, washing machines and baths that would normally be discharged down the soil stack. Instead it is stored in an underground tank, filtered and cleaned. It is then pumped to a high level cistern (separate to the CWSC) and used to flush WCs within the property.

Types of systems Grey water recovery The mains cold water must be protected against any contamination via the grey water.

Types of systems Below ground drainage systems These systems take the discharged soiled water and rainwater away from the dwelling to the main sewers in the road. From there it travels to the sewage plant for treatment. There are three main types of systems that properties are connected to: Separate system Combined system Partially separate system

Types of systems Below ground drainage systems The separate system is favoured by local authorities. Foul water and rainwater flow in separate drainage systems: the foul water connects to the foul water sewer and the rainwater connects to the surface water sewer (foul water includes discharges from the WC, bath, basin, bidet and sink).

Types of systems Below ground drainage systems Separate system

Types of systems Below ground drainage systems Separate system Advantages: Sewage plant is not inundated with water when it rains No trapped gullies are required for rainwater Rainwater does not receive any treatment Disadvantages: Expensive to install Foul water system is not regularly flushed by rainwater Risk of making an incorrect connection

Types of systems Below ground drainage systems The combined system is an older system, where both the foul water and rainwater discharge into the foul water sewer in the road. This system is not recognised by the Building Regulations for new builds.

Types of systems Below ground drainage systems Combined system

Types of systems Below ground drainage systems Combined system Advantages: Maintenance is easier Cheaper to install Impossible to make an incorrect connection All drains are flushed by rainwater Disadvantages: More expensive for the water authority to treat the additional rainwater

Types of systems Below ground drainage systems The partially separate system is a compromise between the previous two systems. Most of the rainwater is conveyed to the surface water sewer, and all the foul water is conveyed to the foul water sewer. The remaining rainwater can either discharge in the foul water sewer or via a soakaway pit. A soakaway is a 1.0m3 pit filled with gravel/stones where a rainwater discharge pipe is placed. The rainwater naturally disperses in the ground. Nowadays you can purchase soakaway kits.

Types of systems Below ground drainage systems Partially separate system

Types of systems Below ground drainage systems Soakaway: used for isolated downpipes from rainwater systems.

Types of systems Below ground drainage systems Key: S&VP: Soil and vent pipe RWG: Rainwater gulley IC: Inspection chamber

Types of systems Below ground drainage systems Partially separate system Advantages: Reduces overall cost of installation Disadvantages: Care must be taken when installing foul water outlets to ensure the correct system is used