Presented by – ANAMIKA BANERJEE (RESEARCH SCHOLAR)

Slides:



Advertisements
Similar presentations
OFFLINE COMPOSITION MEASURING SENSORS
Advertisements

A guide for A level students KNOCKHARDY PUBLISHING
A guide for GCSE students KNOCKHARDY PUBLISHING
GAS CHROMATOGRAPHY CHAPTER 21.
Gas Chromatography 427 PHC.
Lecture 8b Gas Chromatography.
Gas Chromatography & Gas-Liquid Chromatography
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
GAS CHROMATOGRAPHY.
Lab Methods Day June 25, 2014 Gas Chromatography
Chapter 20 Molecular Mass Spectrometry Mass spectrometry is capable of providing information about (1) the elemental composition of samples of matter.
Analysis of Residues. Laboratory Analysis of Debris and Other Samples 1. Preparation of Liquid Samples: Liquid samples are simply drawn into a special.
Gas Chromatography in the detection of Volatile Organic Compounds.
1 Gas Chromatography Lecture a. Thermal Conductivity Detector (TCD) This is a nondestructive detector which is used for the separation and collection.
Lecture 8. GC/MS.
Chapter 20 Molecular Mass Spectrometry. Introduction... Mass spectroscopy is perhaps one of the most widely applicable of all the analytical tools available.
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Instant Notes Analytical Chemistry
Mass Spectroscopy 1Dr. Nikhat Siddiqi. Mass spectrometry is a powerful analytical technique that is used to identify unknown compounds, to quantify known.
Gas chromatography is used in many research labs, industrial labs (quality control), forensic (arson and drug analysis, toxicology, etc.), environmental.
Chromatography Chapter 4.
Gas Chromatography And Mass Spectrometry
Gas Liquid Chromatography
Gas Chromatography. Gas Chromatography Basics Gas Liquid Chromatography (GLC) Gas Solid Chromatography (GSC) Mobile phase does not interact with analyte.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Types of Chromatography Liquid chromatography versus gas chromatography? Applications? Volatile  GC Non-volatile  LC.
Chromatography Year 12.
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
By, Blessy Babu. What is Gas Chromatography?  Gas spectroscopy is a technique used to separate volatile components in a mixture.  It is particularly.
Chapter 6 - Chromatography
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
Chapter 27 Gas Chromatography 1. Principles
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Chromatography Chapter 6.
Separation Science Differences in IMFs can be used to separate chemical substances for further analysis. Differences in IMFs can be used to separate chemical.
Chapter 33 Supercritical-Fluid Chromatography
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
An Introduction to Chromatography What is chromatography? The separation of a mixture by distribution of its components between a mobile and stationary.
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
Gas Chromatography Lecture 38.
By: Arafath and Nick. What is it  Chromatography is a technique that is used to separate the substances present in a mixture.  It is widely used to.
Analytical Separations
HPLC – High Performance Liquid Chromatography
Basic Gas Chromatography. History Separation of dyes by Runge Separation of plant pigments by Tswett Theoretical gc (Martin & Synge)
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
HPLC.
GAS CHROMATOGRAPHY In gas chromatography (GC), the sample is injected onto the head of a chromatographic column and immediately vaporized. The components.
HPLC.
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
ROHAN DEOKAR.  Quite simply, it is a broad range of physical methods used to separate and or to analyze complex mixtures.  The mixture is dissolved.
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
CHROMATOGRAPHY Chromatography is used to separate and analyse small amounts of mixtures Methods involve a stationary phase and a mobile phase. There are.
Experiments in Analytical Chemistry
GC-MS technique & Its application
2008 SPECIFICATIONS HPLC and GAS CHROMATOGRAPHY A guide for A level students KNOCKHARDY PUBLISHING.
A guide for A level students KNOCKHARDY PUBLISHING
GAS CHROMATOGRAPH. GAS CHROMATOGRAPH Principle: Which type of compounds can analyse? Volatile Thermostable.
A guide for A level students KNOCKHARDY PUBLISHING
Chapter 27 Gas Chromatography
An Introduction to Chromatographic Separations
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
VAPOUR PHASE CHROMATOGRAPHY
Chromatography Daheeya Alenazi.
Principle of separation of different components:
A guide for A level students KNOCKHARDY PUBLISHING
GAS CHROMATOGRAPHY.
CHROMATOGRAPHY.
Suppose we make a new compound containing of C,H, and N
Presentation transcript:

Presented by – ANAMIKA BANERJEE (RESEARCH SCHOLAR)

Gas chromatography coupled to mass spectrometry is a versatile tool to separate, quantify and identify unknown (volatile) organic compounds and permanent gases. By combining sensitivity and a high resolving power, complex mixtures can be analyzed. The information obtained can be used for detection of impurities, contamination control and improvement of, for example, semiconductor manufacturing processes

FUNDAMENTAL OF GC Gas Chromatography (GC) uses a carrier gas to transport sample components through either packed columns or hollow capillary columns containing the stationary phase. In most cases, GC columns have smaller internal diameter and are longer than HPLC columns. In Gas Chromatography, the mobile phase is a gas and the stationary phase is either: A solid, commonly termed “Gas solid chromatography (GSC)”. An immobilised polymeric liquid, referred as “Gas Liquid Chromatography (GLC)”. An immobilised polymeric liquid, referred as “Gas Liquid Chromatography (GLC)”. 6

Carrier – (H 2, He, N 2 – helium is most usual with MS detection) Make-up gas– (H 2, He, N 2 - if using an FID detector in parallel to the MS detector) Detector gas – (H 2 & Air – if using an FID detector in parallel to the MS detector) 1. Gas Supply: Gas is fed from cylinders through regulators and tubing to the instrument. It is usual to filter gases to ensure high gas purity and the gas supply pressure. Required gases might include: 2. Interface: After separation in the GC system, analyte species have to be transported to the mass spectrometer to be ionised, mass filtered and detected. The interface in modern instruments is heated to prevent analyte condensation and in some instruments will contain a device to remove carrier gas molecules to allow analyte pre- concentration.

5. Column: Gas Chromatography uses a gaseous mobile phase to transport sample components through columns either packed with coated silica particles or hollow capillary columns containing the stationary phase coated onto the inner wall. Capillary GC columns are usually several meters long (10 – 120m is typical) with an internal diameter of 0.10 – 0.50mm, whilst packed GC columns tend be 1 – 5 meters in length with either 2 or 4mm internal diameter. 6. Injector: Here the sample is volatilised and the resulting gas entrained into the carrier 3. Pneumatic controls: The gas supply is regulated to the correct pressure (or flow) and then fed to the required part of the instrument. Modern GC instruments have ElectronicPneumatic pressure controllers –older instruments may have manual pressure control via regulators. 4. Oven: Gas chromatography have ovens that are temperature programmable, the temperature of the gas chromatographic ovens typically range from 5oC to 400oC but can go as low as -25oC with cryogenic cooling.

Weaknesses of GC: Requires the analyte to have significant vapour pressure between about 30atm and 300 o C. Presents a lack of definitive proof of the nature of detected compounds. The identification process is based on retention time matching, which may be inaccurate or at worst misleading.

INSTRUMENT FUNDAMENTALS –MS The mass spectrometer is an instrument designed to separate gas phase ions according to their mass to charge ratio (m/z) value. mass to charge ratio (m/z): This represents the mass of a given particle (Da) to the number (z) of electrostatic charges (e) that the particle carries. The term m/z is measured in Da/e.

1.Control Electronics: 1.Control Electronics: The MS parameters can be selected and controlled from this panel. Modern instruments will also allow to control MS parameters from a computer by using specially designed software. 2.Detector: 2.Detector: The ion beam that emerges from the mass analyzer, have to be detected and transformed into a usable signal. The detector is an important element of the mass spectrometer that generates a signal from incident ions by either generating secondary electrons, which are further amplified, or by inducing a current (generated by moving charges).

3. Vacuum System: 3. Vacuum System: Mass analysers require high levels of vacuum in order to operate in a predictable and efficient way. The vacuum systems of most modern GC-MS systems consist of a differentially pumped system, usually with a foreline pump establishing a ‘rough’ vacuum and a high vacuum pump or pumps situated on the analyser body to establish the high levels of vacuum required for effective mass to charge ratio measurement. 4. Mass Analyser: 4. Mass Analyser: There are several very popular types of mass analyser associated with routine GC-MS analysis and all differ in the fundamental way in which they separate species on a mass-to-charge basis. 5. Ion Source: 5. Ion Source: In the ion source, the products are ionized prior to analysis in the mass spectrometer.

The Coupling of GC/MS GC-MS has the advantages of higher chromatographic resolution and higher peak capacity, a single mobile phase (helium), fewer issues with solubility and separations can be adjusted by electronic controls such as temperature and flow programming. Today with the advent of capillary columns using relatively low carrier gas flow rates, the need for vapour concentrator devices has been eliminated. The mass spectrometer pumping system can easily deal with gas flows for direct injection into the mass spectrometer.

The Bieman Concentrator The Bieman concentrator device is used with packed columns or with wide bore capillary columns at higher flow rates. In this device the carrier gas is removed in preference to the analyte and hence analyte enrichment occurs.

Direct Introduction Direct introduction is typically used with capillary GC columns and most modern instruments can easily cope with flow rates up to 2 mL/min

Ionisation Mass spectrometry involves the separation of charged species which are produced by a variety of ionisation methods in GC-MS. These include: Electron impact Ionisation (EI) Electron impact Ionisation (EI) - where analyte molecules are directly ionised through collision with a bombarding electron stream resulting in the removal of an electron to form a radical cation species. Chemical Ionisation (CI) Chemical Ionisation (CI) - where analyte molecules are charged through reaction processes with a charged reagent gas plasma producing either anion or cation species depending upon the analyte and analyser polarity.

Electron Impact (EI) In the Electron Impact (EI) process, electrons are emitted from a heated filament (usually made of tungsten or rhenium) and are accelerated across the source by using an appropriate potential (5-100V) to achieve the required electron energy (sufficient to ionize the molecule). M (g) + e - M + + 2e -

Chemical Ionisation (CI) Chemical ionisation involves the ionisation of a reagent gas, such as methane at relatively high pressure (~1 mbar) in a simple electron impact source. Once produced, the reagent gas ions collide with the analyte molecules producing ions through gas phase reaction processes such as proton transfer. nNH 3 + e - NH e - NH M NH 3 + [M+ H] + NH M [M+ NH 4 ] +

GC-MS Process To achieve the identification of different compounds, three steps can be distinguished in a GC-MS system: Sample injection Separation. Separation. Detection Detection

INJECTION Depending on the sample (gas, liquid or solid), compounds in a mixture need to be volatilized or extracted from the matrix INJECTION TECHNIQUE USED FOR Split Split High concentration samples (liquid/gas) Only small amounts of sample required Split-less Split-less Trace analysis (liquid/gas) Thermal Desorption Thermal Desorption Trace analysis (gases) and solid samples Desorption of volatile compounds in a solid matrix Headspace Headspace Volatile compounds in difficult matrices For collection of vapors above dirty samples Solid Phase Micro Extraction (SPME) (SPME) Volatile compounds in difficult matrices with pre- concentration

SEPARATION After injection of a mixture, separation is achieved in the capillary column. This column is coated with a fluid or a solid support, the stationary phase. An inert gas, also called the mobile phase, is flowing through the column. Depending on the phase equilibrium between the stationary and mobile phase, compounds travel with different velocities through the column. The mixture becomes separated, and as a result, individual compounds reach the detector with a different retention time. By choosing a column, which separates on boiling point, polarity, size or stereochemistry, a wide range of compounds can be separated.

DETECTION Many different detectors can be used for detection of the separated compounds. The mass spectrometer combines a high sensitivity with the unique property of being able to determine the molecular composition. DETECTOR USED F OR Flame Ionization Detector (FID)Compounds containing Carbon Thermal Conductivity Detector (TCD)Universal detection for gases without C Nitrogen Phosphorous Detector (NPD)Selective detection of N and P containing organic compounds Electron Capture Detector (ECD)Selective detection of halogen containing compounds Atomic Emission Detector (AED)Selective detection of elemental composition

APPLICATIONS The use of GC-MS in many application areas within analytical science continues to grow almost exponentially. Listed below are some pointers as to the applicability of both GC as a separative technique and MS as a means of detecting analyte species GC analysis of urine sample know to contain cocaine

MS spectrum of cocaine

GC Separations Produce fast analyses because of the highly efficient nature of the separations achieved By using a combination of oven temperature and stationary phase very difficult separations may also be undertaken Excellent for quantitative analysis with a range of sensitive and linear detectors to choose from (including the MS detector) A practical upper temperature limit for conventional GC columns is around o C. In GC analysis, analyte boiling points rarely exceed 400 o C and the upper molecular weight is usually around 500 Da

MS Detection Allows specific compound identification. Structural elucidation via spectral interpretation combined with elemental composition from accurate mass analysers is possible. Allows high sensitivity detection - femto-gram amounts have been detected by certain mass analyzer types. Is highly selective, certain analyzer and experiment combinations can lead to highly selective and sensitive analysis of a wide range of analyte types.

Cleanroom air The presence of airborne molecular contamination (AMC) in cleanroom air can have a negative effect on the health. To assess the level of AMC in a cleanroom several samples are taken using adsorption tubes and sent to the laboratory for analysis. At the laboratory, the adsorption tubes are desorbed at elevated temperature and the organic contamination present is analyzed using GC-MS. Typically, over 100 different compounds are detected, including compounds like cleanroom solvents (acetone, ethyl acetate etc.) and large hydrocarbons. Quantification of the obtained data yields the exact composition of the gas/cleanroom air. Chromatogram of cleanroom air. Some of the characteristic peaks are indicated: 1= ethanol 2= acetone 3= ethylacetate 4= cyclohexanone 5= dodecane

REFERENCES Chromacademy – e- learning for analytical chemistry community : Fundamentals of GC-MS Material analysis by GC-Ms : › analytical services Google Search engine: Wikipedia