Plenum Plenum design is based on Equal Static Pressure using Static Regain Most duct systems are designed to maintain Equal Friction or Equal Velocity.

Slides:



Advertisements
Similar presentations
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Advertisements

Heating Systems Forced Air Systems.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
SUPPLY DUCT SYSTEMS (Additional information. Read sections 18.4, 18.5, & 18.6) General –The supply duct system conveys conditioned air from an AHU to the.
1 HVAC SHEET METAL SHEET METAL THEORY. 2 THE AIR DISTRIBUTION SYSTEM SHEET METAL IS USED FOR: – PLENUM’S (RETURN & SUPPLY) –TRUNK LINES –RETURN AIR GRILLS.
Heating and Air Conditioning I
Nonmetallic ducts (Additional information) –Fiberglass (also see section 18.5) Made of glass wool insulating material in which the stranded fiber wool.
Objectives Finish with ducts and fans Define project topics.
Arthur Miller, CMS, RCT HVACR Training Consultant
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Airflow Properties & Measurement
Trevor Thompson Senior Project II Vermont Technical College Spring 2011.
System Sizing. Proper System Design Load Calculation Equipment Selection Duct Layout Branch runs Terminations Start ups Customer checks.
ARCH-4372/6372 HVAC Distribution & Sizing HVAC Distribution Systems
Announcement Course Exam October 11 th (Tuesday) In class: 90 minutes long Examples are posted on the course website.
HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman
Installing & Maintaining Irrigation Systems Ms. Gripshover Landscaping Unit 15.
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
PTCS DUCT SEALING SPECIFICATIONS The Perfect Spec : Simple as possible Achievable by the motivated, not just the true believer Assure that energy savings.
Welcome to Field Controls: HRV / ERV Training Duct Systems Part 3
2006 Oct. 19 DES Project -- Vaidas Simaitis, University of Illinois1 DHE – Detector Head Electronics Monsoon 80mm Crate Heat Load.
Generation Geo. EXPECTED SAVINGS Savings vary by region and energy costs Savings happen large or small homes Natural gas prices today are artificially.
Pipe Sizing Sizing Gas Pipe for Low-Pressure Systems
Hi-Velocity Tubing Runs. How to get it where you need it! System Installation copyright Mestek, Inc
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Basics Air Flow Basics -Air is invisible -Everyone assumes adequate airflow -Frequently airflow is 30%-50% low -Cooling – 400 CFM per ton -Heating.
Chapter 12: Fans and Building Air Distribution
The International Authority on Air System Components Fan Performance Mark Stevens Director of Laboratory Services AMCA International.
Plenum Runs Plenum Runs. Plenum Run Usually located in the attic or basement. Run in any location accessible for attachment of supply tubing. More economical.
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Dimensional Analysis or Unit Analysis
Drafts and Duct System Sizing
HVACR116 – Trade Skills Pipe Sizing Sizing Gas Pipe for Low-Pressure Systems.
HVACR416 - Design Air Distribution Part 2. Air Ducts Air carriers that deliver air to conditioned space. Originally hot air ducts were thin, tinned sheet.
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Objectives Airflow in Ducts Fluid dynamic review Duct Design.
3.4 Equal friction method This method of sizing is used for supply, exhaust and return air duct system and employs the same friction lose per foot of length.
Objectives Describe room distribution basics Select diffusers
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Technology in Architecture Lecture 11 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 11 Mechanical System Space.
AIR CONDITIONING (COOLING) UNIT 37 AIR DISTRIBUTION AND BALANCE
What makes up a Unico System
Elbow Sound Attenuator (UPC-26C) Outlet (UPC-56B) Plenum Supply Tubing (UPC-25) Blower Modules (2430,3642, 4860) Heating Module (MH2430, MH3660) Cooling.
Duct Design Basics Lesson 4 Manual D Primer. Available Static Pressure 4.4.
Duct Design Basics Lesson 3 Calculations. Fitting losses, System Effect 3.4.
Lesson 1 Friction Chart Primer 1.3 Friction Chart.
Duct Design Basics Lesson 4. Knowledge & Skills for Manual D 4.1.
Chapter 6 technology institute of HAVC from usst INDUSTRIAL VENTILATION TUTORIAL 王丽慧.
Airflow Measuring Stations
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Lesson 21 Appendix C Duct Design
Sound Attenuator (UPC-26C)
Airflow Quantity and Velocity
and the like in the pipe or duct system.
Measuring Inches.
MECH 8250 – Building Systems Winter 2015
Unico Installation Rules
HW4 Problem (Use TITUS Square Ceiling MCD diffuser
Sound Attenuator (UPC-26C)
Objectives - Learn about fans and fan curves
High Performance HVAC Installation
Mandatory Design Requirements
FBE03: Building Construction & Science
Follow-ups from Classes 8 and 9
Mathematics of Air Filtration
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Lesson 22 Appendix C Zone 2 Duct Design
Objectives Air Distribution Systems Duct design HW4.
Copyright Materials This educational activity is protected by U.S. and International copyright laws. Reproduction, distribution, display, and use of.
Presentation transcript:

Plenum Plenum design is based on Equal Static Pressure using Static Regain Most duct systems are designed to maintain Equal Friction or Equal Velocity Static Regain – robs the energy from the moving air (high velocity) to create static pressure to over come friction in the duct so that equal pressure is obtained.

Short Rules of Unico A Summary

Airflow Airflow A MINIMUM OF 200 CFM per ton MUST be maintained at all times

Not Equal Friction This is what most think of for Warm Air Systems

Unico System Uses Static Regain An Example of Static Regain

Plenum Sizing These are MINIMUMS, to be safe you can always use 10” Diameter Max CFM Typical Model 7” 700 1218 or 2430 9” 1000 3642 10* 1300 4860 These are MINIMUMS, to be safe you can always use 10”

Plenum Length – Rule of Thumb Plenum can be up to 150’ equivalent length First Tee = 30’ All other = 15’ Elbows = 15’ Total plenum in the sizes provided can be up to 150’. If the first fitting is a Tee it is equal to 30’. All fittings after that are equal to 15’. Be sure to use 4’ straight duct between fittings – minimum is 2 ‘. 7

60/40 Rule Split 50/50, no more than 60/40 Applies to all tees If you have a tee in the system split the flow as close to 50/50 as possible, no more than 60% of the air flow on either side of the tee. This rule is true for every tee in the system although it is most important for the first tee. Any tees after that can be as much as 80/20 without problems. Q: Assuming that we are using 20 Fully Rate Outlets. What is the max on each side of the tee and of those tees? A: 8

70/30 RULE No more than 30% of CFM on side branch Turn a tee 90 degrees and you have a side branch (do not use the turning vane). The side branch can have no more than 30% of the total CFM. 9

24 Inch Rule You must be a minimum of 24 inches from the exit of the blower before any fitting or take off. 10

Space Takeoffs evenly Maintain spacing between takeoffs as evenly as possible. Minimum 6 inches between takeoffs and 12 inches from end cap. 11

For Every 5 feet Over 10 You Lose 10% of Capacity Keep runs at 12 feet or less (if possible) The longer the run the less air is delivered

Steps to a Unico Layout 1. Do a total load calculation for the buildings 2. Do a room by room load calculation 3. Determine where the air handler/return will go 4. Run the plenum as long as you can to connect the tubing 5. “Connect the Dots”