Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.

Slides:



Advertisements
Similar presentations
Energy Audit Kaylin Fitzgerald Environmental Science Mr. Fitzgerald.
Advertisements

International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
How to lower the energy use of your home David Parker Building Analyst/ Energy Auditor Parker Energy Solutions David Parker Building Analyst/ Energy Auditor.
C HAPTER 4 C OMBUSTION A IR The importance of combustion, dilution, and ventilation air.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Combustion Appliances
Performance measurement
“Do not take anyone’s advice as to how this building should be assembled.”
Heating, Ventilating, and Air-Conditioning (HVAC)
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
ENERGY STAR Qualified Homes
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov House as a System WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Missouri Weatherization Assistance Program. Missouri Weatherization Program Mission  Reduce the energy burden on Low- income residents by installing.
Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
The House as a System 1. Air Temperature and Water Vapor.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Combustion Appliances WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 5 Validating Combustion Air.
1 Steps to Healthier Homes n Start with People n House as a System n Keep It: DryClean Pest-Free Ventilated SafeContaminant-Free Maintained n Making it.
WARM CHOICE Program Combustion Safety Testing Energy Essentials Core Contractor Training December 10 and 11, 2008 Four Points by Sheraton, Mars, PA A.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Blower Door Basics WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
Training the Best Workforce! Larry D. Armanda Therma-View Infrared and Energy Consultants S. Williamsport, PA & A. Tamasin Sterner Pure Energy Coach LLC.
VENTING AND COMBUSTION AIR
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
DST H.O.M.E. Home Ownership Maintenance and Education Property Maintenance: Protect Your Property Value.
Weatherization 301: Weatherization Works! Updated September 23, 2008.
Your House as a Healthy System Bruce Stahlberg. Improvements / Remodeling When one has finished building one's house, one suddenly realizes that in the.
Carbon Monoxide Safety
NFPA 54 National Fuel Gas Code Boiler Manufacturer ANSI Standards Local Codes Vent Manufacturer.
Introduction Assessing the Health and Sustainability of the Home /Interactions with the Environment Jed Harrison U.S. EPA.
HVACR311 – Electrical for Refrigeration International Mechanical Code Relating to Refrigeration.
Healthy Homes Overview Ventilation. Learning Outcomes Upon completion of this module you will be able to:  Identify the basic operating principle of.
Be the MVP in the CAZ: Combustion Testing for Beginners ESSN 1 Wednesday, April 21, :30 am to Noon 2010 National ACI Conference, Austin TX A. Tamasin.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov House as a System WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
NFPA 31 Standard for the installation of Oil- Burning Equipment
Residential Weatherization and Ventilation Subcommittee Seeking RTF Direction on Ventilation and IAQ Requirements May 3, 2011 Subcommittee: Residential.
Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.
ASHRAE A Ventilation Standard for Residential Structures Ventilation and Acceptable Indoor Air Quality in Low- Rise Residential Buildings.
Insulation and Infiltration
Why Weatherization? Low-income families often choose between heat and other necessities 33.8 million households nationally eligible for Weatherization.
Updated Space Heater Policy For Weatherization -- Draft National Weatherization Training Conference Orlando, FL December 10, 2007.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 10 Spillage Test.
HVACR116 – Trade Skills Longest length method.
1 HVACR318 – Refrigeration II International Mechanical Code Relating to Refrigeration.
1 Mansel Nelson, ITEP–EEOP. 2 3 Safety Perform regular maintenance Avoid installing unvented (or "vent-free”) heating appliances Consider using only.
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
Day 2 Part 1 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
3.0 Comprehensive Performance Audit Fossil Fuel Appliances Health & Safety 3.2.
Day 2 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
4.0 Equipment Installation Aspects (Section 4.5 On-Rate for Fuel-Fired Equipment)
Day 4 Part 1 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Duct Sealing and Insulation TRAIN THE TRAINER WEATHERIZATION.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 3 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – March 2011eere.energy.gov COMBUSTION BASICS HEATING SYSTEMS FOR ENERGY AUDITORS AND INSPECTORS.
Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 1 Part 1 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Part 13 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Math Review CAZ Volume and Air Free CO PPM Calculations
Part 12 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Things you need to know before you play the game
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Presentation transcript:

Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement

3.0 Comprehensive Performance Audit Fossil Fuel Appliances Health & Safety 3.2

Gas/Oil Leakage Testing

Acceptable Documentation Written or recorded records of where the leaks were located are required and shall be kept in the job file along with a copy of the homeowner’s notification. Note: a good practice is to include a picture of the marked leakage locations in the job file.

Unvented Combustion Appliances

ANSI Z

Acceptable Documentation Written or recorded records evidence of the location of the unvented appliance. And Written or recorded records evidence that the equipment is ANSI Z listed. Or Written or recorded records evidence of the total appliance input and homeowner notification if the appliance is not listed.

Combustion Appliance Zone Area (CAZ) Pre Test Area Measurement

CAZ Area Measurement Calculations The volume of the space providing combustion air to fossil fuel appliances must be measured and, if provided, the net free area of openings which supply combustion air from an adjoining room or the outdoors, including any bird/insect screen on opening terminations. Acceptable procedures are: National Fuel Gas Code (NFG) §9.3, Or Authority having jurisdiction (AHJ).

National Fuel Gas Code (NFG) §9.3 “Standard Method” Requires a blower door leakage measurement’s results in air changes per hour (ACH). ACH must be more than 0.40 per hour Must calculate all of the rooms connected Must add the total Btuh of all appliances in the connected rooms

Sample Problem 1 “Standard Method” Sample Problem A 1,200 ft 2 home with 9 ft ceilings according to the blower door test has 0.50 ACH and a 148,000 Btuh gas furnace. Is there enough air leakage to support safe combustion? First the ft 3 is calculated: 1,200 ft 2 x 9 ft = 10,800 ft 3

Sample Problem 1 Next divide 10,800ft 3 by 50ft 3 per 1,000 Btuh = 216 (how many 50ft 3 areas of makeup air per hour there are in the home). Next multiply the 216 by 1,000 Btuh to get the maximum combustion appliance total for the home: 216 X 1,000 = 216,000 Btuh

Sample Problem 1 The Btuh allowable for this leakage rate and home area is 216,000 Btuh This leaky home could easily support the combustion air needs of the 148,000 Btuh Furnace

National Fuel Gas Code (NFG) §9.3 “Formula Method” Where the infiltration rate is known and the ACH is less than 0.60: the minimum required volume can be calculated using one of two formulas. The first is for appliances other than fan- assisted. The second is for fan-assisted appliances.

Fan Assisted vs Natural Draft

Fan Assisted

Fan Assisted vs Natural Draft Natural Draft

Other Than Fan Assisted Formula Naturally vented appliance (boiler or furnace) formula: Required volume ≥ [21ft 3 X all appliances input Btuh] ÷ [ACH X 1,000 Btuh]

Fan Assisted Formula Fan assisted appliance (boiler or furnace) formula: Required volume ≥ [15ft 3 X for the fan assisted appliance input Btuh] ÷ [ACH X 1,000 Btuh]

Sample Problem 2 A 1,200 ft 2 home with 9 ft ceilings according to the blower door test has 0.50 ACH and a fan-assisted 148,000 Btuh gas furnace, a 48,000 Btuh oven, and a 60,000 Btuh domestic water heater. Will combustion ventilation air need to be added? Note: ACH ˂ 0.60 First plug the numbers into the fan assisted formula to calculate the area for the furnace: Required volume ≥ [15ft 3 X 148,000 Btuh] ÷ [0.50 X 1,000 Btuh] ≥ 4,440ft 3

Sample Problem 2 Next do the calculation using the formula for the naturally vented appliances: Required volume ≥ [21ft 3 X (60, ,000)] ÷ [0.50 X 1,000 Btuh] ≥ 4,536ft 3 Next, add up the two for the total required volume: 4,440ft 3 + 4,536ft 3 = 8,970 ft 3

Sample Problem 2 Next, compare the combined area to the required 8,970 ft 3 Since the home area is 10,800ft 3 and since 10,800ft 3 ≥ 8,970 ft 3 this home will pass these combustion air requirements.

Depressurization Test 1.9 (AKA CAZ Test)

Depressurization Test Evidence that the combustion appliance operates safely during periods of depressurization generated by the occupants must be provided by the technician. A combustion appliance zone (CAZ) test is used to show that on the day the testing was done there were no pressure related problems that were negatively influencing the combustion process. CO safety measurements are monitored and recorded for safety when the CAZ test is being performed.

Depressurization Test When the authority having jurisdiction provides requirements for CAZ testing that procedure must be followed. For other cases the procedure to follow for a CAZ test is to do the following 10 steps in order: Step 1 Close all exterior windows and doors, and attic hatches. Temporary openings to the outside such as broken windows must be sealed.

Depressurization Test Step 2 Drain traps must all be filled with water

Depressurization Test Step 3 Turn on all indoor fans: bathroom exhaust, range hood, clothes dryer, powered attic ventilation fans (with the exception of a whole house exhaust fans). Step 4 Turn on the air handler fan. If the pressure differential in the CAZ with reference to the outdoors gets more negative, leave the air handler on; otherwise, turn it off.

Depressurization Test Step 5 Open or close interior doors to the CAZ, rooms with exhaust fans (e.g., bathroom), or other interior rooms to achieve the highest pressure differential in the CAZ room with reference to (WRT) the outdoors. Step 6 Make-up air systems, combustion air ducting, and ventilation systems are to remain as is.

Depressurization Test Step 7 Ensure the vent or flue is at room temperature. Step 8 Fireplace damper shall be closed or a simulator must be operating in the fireplace (camping stove, etc.) with fireplace damper open.

Depressurization Test Step 9 Place the smallest Btu input appliance being tested into operation (per OEM instructions) first and adjust the thermostat so the appliance operates continuously. Step 10 Test for spillage at the draft hood relief opening after five (5) minutes of operation. Use the flame of a match, candle, or smoke. The complete circumference of the draft hood relief opening shall be tested.

Spillage Test If smoke or flame is pulled into the vent the combustion appliance passes. If draft is not established in 5 minutes around the complete circumference of the draft hood opening, then the combustion appliance fails the test.

Spillage Test For additional fossil fuel appliances in the same room, turn on the next appliance being tested so it operates at the full input while the previous appliance continues to operate. Repeat step 10 on the appliance being tested.

Acceptable Documentation Written or recorded records of CO measurements that were required for the home and a note that combustion drafting was working properly during the back draft test shall be kept in the job file. Additional records for a failed Back draft test include: Evidence or written notification of a failed test Evidence of homeowner notification Evidence of repair work done before Home performance improvements were implemented (Note: this can be based on a test at a later date that provides proof that the CO level problems have been addressed)