CIBSE HCNW 28 August 2014 Modular boilers. Traditional or low-tech replacement boiler installation; Multiple boilers eg 2 no 66% of load for security.

Slides:



Advertisements
Similar presentations
Presentation Heading Air Source Heat Pumps Jordan Jeewood
Advertisements

Control calculations Heat Engines & Boilers.
HVAC523 Heat Sources.
Energy Efficient Steam Systems
Heat Exchanger Network Retrofit
Using Copper Water Loop Heat Pipes to Efficiently Cool CPUs and GPUs Stephen Fried President Passive Thermal Technology, Inc.
Installation of New CHP system at the Old Aberdeen Campus.
Heat Recovery for Commercial Buildings
Heat from Street Street Capturing Energy System Supervisor: Eng. Ramez Khaldi The students Abdullah Qalalwah Amjad M. Dwikat Hamza Sameer.
Learning Outcomes Upon completion of this training one should be able to: Identify open loop and closed loop campus-type hydronic water system applications.
Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.
Ground Loop Design. Heat Sources Horizontal ground loops  Collector pipework laid horizontally  Requires large land area  Cost.
Booster System Basics: Constant Speed Systems
Driving Toward Energy Efficiency Emerson Process Management Novaspect. Inc. June 22 / 23, 2010 Steam.
Presented by: Terry Stohs Viessmann Manufacturing Company Inc.
Engineer Presentation
Marine Auxiliary Machinery
Steam Power Plant.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Fuel Evaporation in Ports of SI Engines P M V Subbarao Professor Mechanical Engineering Department Measure of Useful Fuel …..
Kern Method of SHELL-AND-TUBE HEAT EXCHANGER Analysis
Basic Hydraulics Irrigation.
Renewable Technologies Available in Ireland Paul Kane.
STEAM HEATING.
Chilled Water Systems Total Cost of Ownership
ISAT Module V: Industrial Systems
Exergy Analysis of STHE P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Formalization of Thermo-economics…..
Components of Centrifugal pumps
Water piping design.
HVAC523 Circulator Pumps.
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
For Cardinal Newman Hall Randall Lessard ET Fall 2013 Dr. Cris Koutsougeras Advisors: Dr. Rana Mitra Mr. Byron Patterson.
ME421 Heat Exchanger and Steam Generator Design Lecture Notes 6 Double-Pipe Heat Exchangers.
Lecture Objectives: Finish with thermal storage systems Plumbing Hydronic distribution systems –Chiller/Boiler – Storage – Building.
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
Mission Energy: Energy Efficient Cooling How Data Centre energy consumption and operating costs can be significantly reduced through readily available.
Pressure drop during fluid flow
SIZING PNEUMATIC SYSTEMS. Introduction Pneumatic systems are sized to meet output power requirements. The air distribution system is sized to carry the.
Lesson 8 SECOND LAW OF THERMODYNAMICS
Lindab Solus - Simply the natural choice.... lindab | comfort Chilled beam revolution! + Save up to 45 % cooling energy!* + Installation and investment.
Lesson 21 Laminar and Turbulent Flow
NOVO ETS IMPROVING YOUR ORGANIZATIONS’ ENVIRONMENTAL, HEALTH AND SAFETY PERFORMANCE ENERGY MANAGEMENT IN THE CONTEXT OF GREEN PRODUCTIVITY.
Alex Gee Jon Locke Joe Cooper Kylie Rhoades Clara Echavarria Ice Energy Extraction.
Zoning Hydronic Systems. Zone Control Divides the Space to be Heated 1.Each with its own heating needs and control systems 2.There are several reasons.
Sizing Variable Flow Piping – An Opportunity for Reducing Energy
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Exquisite Heat For Steam Boilers. Time based system  Thermostat Demand Analysis over time will determine the length of burner fire time of the boiler.
1 Hospital Building and Campus Piping. 2 Hospital Building Occupancy – office and patient areas Patient areas: 24 hours per day Office areas: 8 am – 5.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
Oddgeir Gudmundsson Applications Specialist Danfoss
Experiment 6: Rankine Cycle Yvette Triay Reporter Group 3.
Heat Engines A gasoline engine is a form of a heat engine, e.g. a 4-stroke engine INTAKE stroke: the piston descends from the top to the bottom of the.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Kaeser Compressors, Inc.
I Need A Space Heating System Let’s Look At A Central Steam Plant Option.
Flow Characteristics of Port Fuel Injection System P M V Subbarao Professor Mechanical Engineering Department Matching of Injector with Engine Requirements.
Boiler Energy Saver Advanced Boiler Controls. Most boiler controls at present consist of a switch!
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: July 7, 2009 Calculation of the integrated energy performance of buildings.
R.N.S. INTERNATIONAL Heat Pumps
Lecture Objectives: Learn about thermal storage systems
Unit 42: Heat Transfer and Combustion
Energy Efficient Building Components
Kaeser Compressors, Inc.
Chemical Engineering Explained
Outcome 4 Mechanical central heating controls Unit 208: Central heating systems.
Chapter 16 A: PUMPS AND SYSTEM EFFECTS
FBE03: Building Construction & Science
Presentation transcript:

CIBSE HCNW 28 August 2014 Modular boilers

Traditional or low-tech replacement boiler installation; Multiple boilers eg 2 no 66% of load for security Step control for boilers Constant speed pumps Large flow rates through boilers to match 82/71 o C flow rate of existing system

An alternative for a replacement boiler installation; One truly modular boiler, full modulation, matched to load but still providing security An internal cascade control that maximises efficiency Variable speed pumps that match load and reduce electricity consumption A Low Velocity Header that matches boilers to system even when  T through boilers differs from that of the system

Multiple module arrangement

Air Gas Mix Air/Gas Pre-mix gas and air burners

Primary pump and Low Velocity Header

Condensing boiler operating at full load

Condensing boiler with multiple boilers each at 33% load Part L NDBS CG heat generator seasonal efficiency recognises that boilers are more efficient at part load than at full load operation

Efficiency 30% and 100% load profiles

Modulating pump vs constant flow How does reducing the flow rate affect the  T? CIBSE AM explains how the partial closing of a 2-port valve lowers heat emissions and reduces return water temperature; “This reduction in water temperature can be explained by the fact that the heat emitted from a radiator does not share a linear relationship with the flow rate. As the flow rate reduces to, say, half of its original value the heat emitted to the room only reduces to 80 or 90% of the original output.

Modulating pump vs constant flow “Using kW = kg/s x shc x  T “if the flow rate reduces to 50% but the heat output only reduces to 90% then the temperature differential must increase to 90/50 = 180% of its original value, i.e. a temperature difference of 10K increases to 18K.”

Modulating pump vs constant flow Modulating pump maximises the  T between flow and return, keeping the boiler in condensing mode for longer. Results can be seen in the reduced flue gas temperature and corresponding increase In overall efficiency as more heat is exchanged to the system

Flue gas temperature comparison

Variable speed pump performance

Low Velocity Headers

Vertical Low Velocity Headers

Low Velocity Headers Carnot’s Engineering Data Sheets require the inclusion of a Low Velocity Header (LVH) whenever a condensing boiler is installed in a new or existing heating system. It ‘hydraulically decouples’ the boiler from the distribution system, allowing the boiler to operate under temperature and flow conditions that may differ from those of the system. It also enables circulating pumps to be located at different positions on the boiler side and system side of the LVH (eg in the return on the boiler side and in the flow on the system side) without affecting their performance. As an alternative, a plate heat exchanger can be used to completely separate a boiler from the system rather than just ‘decouple’ it. It enables a boiler to be used when its maximum allowable pressure rating is less than the static head of the system and will protect the boiler from the deposition of system particulates and debris. However, decoupling the boiler with a LVH rather than separating it with a plate heat exchanger offers some unique and positive benefits that can be summarised as; Permits distribution pumps to be located on the flow, even though boiler pumps may be located on the return Enables effective heat exchange between boilers and the system when these are operating at different flow rates and different temperature gradients eg boilers at DT20K and system at DT11K. Will protect the boiler from particulate and debris deposition if a filter or strainer is also fitted (which is a benefit common with the PHE).

Low Velocity Headers An air separator is often mounted at the top of the LVH because the relative stillness allows dissolved oxygen to escape from the water. A baffle plate may be fitted between the boiler flow and heating flow, to divert and further reduce the water flow rate. If the LVH is also intended to act as a microbubble air separator, then a packing may be introduced into the area of laminar flow to which the microbubbles can attach and be removed by the air vent. Most systems will have a turbulent flow (ie Re > 10, refer a typical Moody Chart). Due to the increased diameter of the main section of pipe forming the LVH, the mass flow rate of the system at this point is reduced to something closer to laminar (f [friction coefficient] = 16 / Re). As a rule of thumb, around 0.1 – 0.2 l/s velocity. The LVH diameter is calculated as a product of relative roughness (k / d) of the construction material, fluid density and mass flow rate. The ideal LVH diameter (d) is that which delivers the most suitable Re number. Taking into account the different temperatures and flow rates that may exist between the Boiler side (Primary) and System side (Secondary) of the LVH is important in determining the correct sizing. A common complaint when this is not considered is that the boiler reaches set point temperature but the system does not.

Ideal match of system to boiler – Identical  T both sides of LVH

 T20 on boiler side of LVH and  T10 on system side QSecondary > QPrimary Reverse flow in header Constant return temperature

 T20 on boiler side of LVH and  T10 on system side

 T5 on boiler side of LVH and  T10 on system side QPrimary > QSecondary Forward flow in header Constant flow temperature

 T5 on boiler side of LVH and  T10 on system side

Low Velocity Headers Installing a variable speed rather than fixed speed pump on the primary side of the LVH will help maintain a flow rate that is ideal for maximising the  T and  P between the primary and secondary sides. A LVH is an essential but often overlooked component when a condensing boiler is to be installed. When correctly sized for the boiler and system, it will allow pumps to be sited on either flow or return, eliminate the problems of mismatched boiler and system flow rates and temperatures, and protect the boiler for many years to come (if used in conjunction with air separators, strainers or filters).

Vatican 5 Modulex 630

In summary; Truly modular boilers offer capital cost savings by reducing the number of boilers and corresponding savings in installation costs without compromising security An internal cascade control increases efficiency by running a maximum number of modules at minimum output Variable speed pumps match load, increase efficiency and reduce electricity consumption A Low Velocity Header matches boilers to system even when  T through boilers differs from that of the system

Why be concerned with Gas boilers if we are running out of gas anyway?

Total Gas reserves are trillion m3 Total annual production in 2013 is 3.39 trillion m3 Therefore, at this rate of production, reserves will last 55 years Based on Laherrere model, gas production will peak in 2030, Followed by a sharp decline Source; Energy Institute June 2014