AIR CONDITIONING (COOLING) UNIT 37 AIR DISTRIBUTION AND BALANCE

Slides:



Advertisements
Similar presentations
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
Advertisements

Construction Methods and Materials HVACR HVACR. Construction Methods and Materials HVACR Comfort Equipment required to control: Temperature Moisture Air.
CON 4003 Construction Estimating Prof R. V. Locurcio.
1 Trade Skills HVACR116 Fiberglass Duct Board and Insulation Material.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
HVAC CONTROLS (See section 18.9)
Lodging HVAC and Refrigeration
Heating, Ventilating, and Air-Conditioning
TYPES OF MECHANICAL SYSTEMS
Heating Systems Forced Air Systems.
Fluid Power Systems Mill Creek High School Power and Energy.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Components of HVAC System
SUPPLY DUCT SYSTEMS (Additional information. Read sections 18.4, 18.5, & 18.6) General –The supply duct system conveys conditioned air from an AHU to the.
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
1 HVAC SHEET METAL SHEET METAL THEORY. 2 THE AIR DISTRIBUTION SYSTEM SHEET METAL IS USED FOR: – PLENUM’S (RETURN & SUPPLY) –TRUNK LINES –RETURN AIR GRILLS.
BASICS OF HVAC Ivy Tech Community College. Definitions – Page 862 HVAC systems are made up of the mechanical equipment such as the furnace, air conditioner,
Heating and Air Conditioning I
Nonmetallic ducts (Additional information) –Fiberglass (also see section 18.5) Made of glass wool insulating material in which the stranded fiber wool.
Arthur Miller, CMS, RCT HVACR Training Consultant
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Airflow Properties & Measurement
Section 4: Electric Motors
Trevor Thompson Senior Project II Vermont Technical College Spring 2011.
System Effects Presented by: Joe Brooks, AMCA International, Inc. AMCA International Technical Seminar 2009.
System Sizing. Proper System Design Load Calculation Equipment Selection Duct Layout Branch runs Terminations Start ups Customer checks.
ARCH-4372/6372 HVAC Distribution & Sizing HVAC Distribution Systems
HVACR416 - Design Air Distribution Air Properties and Behavior Important properties of interest include: o Weight of air. o Manner in which air.
1 Trade Skills HVACR116 Sheet Metal. 2 The most common types of duct material are: –Aluminum –Fiberglass duct board –Spiral metal duct –Flexible duct.
Welcome to S&P USA & the 2012 International Residential and Mechanical Code for Ventilation.
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
Welcome to Field Controls: HRV / ERV Training Duct Systems Part 3
STEAM HEATING.
AIR CONDITIONING (COOLING)
Hi-Velocity Tubing Runs. How to get it where you need it! System Installation copyright Mestek, Inc
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
HVACR416 - Design Duct Fittings and Components. Elbows Elbows are 90° bends (unless otherwise specified) in ducts. Airflow is diverted from a straight.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
NSTX TF Bundle & Center Stack Curing Oven Mike Viola Joe Rushinski Frank Jones April 14, 2003.
Chapter 12: Fans and Building Air Distribution
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Air Handler Terminology
Air Handler Terminology
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Drafts and Duct System Sizing
1 Air Conditioning Air System problems. 2 The primary problem that can occur in an air system is the reduction in airflow. Air handling systems do not.
HVACR416 - Design Air Distribution Part 2. Air Ducts Air carriers that deliver air to conditioned space. Originally hot air ducts were thin, tinned sheet.
Why Maintenance Tasks are Important Produced by Joe Marchese.
CHILLED WATER AIR-CONDITIONING SYSTEMS
HVACR416 - Design Pressure Measurement Part 1. Why Measure? Need to Make Sure: All combustion appliances vent properly All HVAC systems are installed.
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
HEATING AND COOLING SYSTEMS
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
3.4 Equal friction method This method of sizing is used for supply, exhaust and return air duct system and employs the same friction lose per foot of length.
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Plenum Plenum design is based on Equal Static Pressure using Static Regain Most duct systems are designed to maintain Equal Friction or Equal Velocity.
TROUBLESHOOTING ELECTRIC MOTORS
Duct Design Basics Lesson 4 Manual D Primer. Duct Sizing 4.3.
Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Chapter 14 Heating, Ventilation & Air conditioning (hvac)
Maria’s Restaurant Chapter 3 Section 13
Heating Ventilating and Air Conditioning
Ritchie Yellow Jacket Instrument Applications
Air Distribution Control
MECH 8250 – Building Systems Winter 2015
Unico Installation Rules
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
FBE03: Building Construction & Science
Presentation transcript:

AIR CONDITIONING (COOLING) UNIT 37 AIR DISTRIBUTION AND BALANCE SECTION 7 AIR CONDITIONING (COOLING) UNIT 37 AIR DISTRIBUTION AND BALANCE

UNIT OBJECTIVES Describe propeller and centrifugal fans and blowers After studying this unit, the reader should be able to Describe propeller and centrifugal fans and blowers Explain how to take air pressure measurements Explain how to measure air quantities List various types of air-measuring devices Describe common types of motors and drive assemblies Identify and describe various duct systems Explain how air from the conditioned space returns to the air handler

CONDITIONING EQUIPMENT Air has to be conditioned in most cases for us to be comfortable Equipment includes cooling coil, heating device, device to add humidity, and device to clean air Forced air systems use the same room air over and over again Fresh air enters the structure by infiltration or by mechanical means

Mechanical means to introduce ventilation Return air from the occupied space Damper in fresh air duct Supply duct Air handler Fresh air from outside the structure

CORRECT AIR QUANTITY The forced air system delivers the correct quantity of conditioned air to the occupied space Different spaces require different air quantities Same structure may have several different cooling requirements

Living Room 9,000 btu (cooling) 18,000 btu (heating) 300 cfm

THE FORCED-AIR SYSTEM Components that make up the forced-air system The blower Air supply system Return air system Grilles and registers Occupants should not be aware if the system is on or off

Return air from the occupied space Supply registers Supply duct Air handler (blower)

THE BLOWER Provides the pressure difference to force the air into the duct system, through the grilles and registers, and into the room Typically 400 cfm of air must be moved per minute per ton of air conditioning Pressure in the ductwork is measured in inches of water column (in. W.C) Air pressure in the ductwork is measured with a water manometer

SYSTEM PRESSURES Duct system is pressurized by three pressures Static pressure – air pressure in the duct Velocity pressure – pressure generated by the velocity and weight of the air Total pressure Static pressure plus velocity pressure equals total pressure

Probe located on the surface of the duct Static pressure Airflow Duct

Probe located in the duct, facing into the direction of airflow Total pressure

Velocity pressure = Total pressure – Static pressure

AIR-MEASURING INSTRUMENTS FOR DUCT SYSTEMS Velometer – Measures actual air velocity (how fast the air is actually moving in the duct) Air volume in cfm can be calculated by multiplying the air velocity by the cross-sectional area of the duct in square feet Pitot tube – Used with special manometers for checking duct pressure

PROPELLER FAN Used in exhaust fan and condenser fan application Will handle large volumes of air at low pressure differentials Set into a housing called a venturi The venturi forces airflow in a straight line from one side of the fan to the other Makes noise and is used where noise is not a factor

Propeller fan Venturi

SQUIRREL CAGE OR CENTRIFUGAL FAN Desirable for ductwork Builds more pressure from the inlet to the outlet Has a forward curved blade and a cutoff to shear the air spinning around the fan wheel Very quiet when properly applied Can be used in very large high-pressure systems

End View of Squirrel Cage Blower Wheel Centrifugal Blower

CENTRIFUGAL BLOWER HOUSING

TYPES OF FAN DRIVES Belt-drive blowers have two bearings on the fan shaft and two bearing on the motor Motor pulleys and fan motor pulleys can be adjusted to change fan speeds Direct-drive motors use no pulleys or belts Direct-drive motors can be multi-speed motors Speeds can be changed by changing motor wire leads

BOTH THE DRIVE AND DRIVEN PULLEYS MUST BE PERFECTLY ALIGNED Belt-driven Assembly BLOWER BOTH THE DRIVE AND DRIVEN PULLEYS MUST BE PERFECTLY ALIGNED MOTOR

DIRECT DRIVE MOTOR ASSEMBLY THE MOTOR AND THE BLOWER TURN AT THE SAME SPEED

THE SUPPLY DUCT SYSTEM Distributes air to the terminal units, registers, or diffusers in the conditioned space Duct systems Plenum system Extended plenum system Reducing plenum system Perimeter loop

THE PLENUM SYSTEM Suited for a job where the room outlets are all close to the unit Supply diffusers are normally located on the inside walls Work better on fossil-fuel systems Fossil-fuel supply air temperatures could easily reach 130°F

Plenum system Supply plenum Branch ducts Return duct

THE EXTENDED PLENUM SYSTEM Can be applied to a long structure This system takes the plenum closer to the farthest point Called the trunk duct system Ducts called branches complete the connection to the terminal units

THE EXTENDED PLENUM SYSTEM Living Room 9,000 btu (cooling) 18,000 btu (heating) 300 cfm 100 cfm 200 cfm 100 cfm 200 cfm 50 cfm 50 cfm

THE REDUCING PLENUM SYSTEM Reduces the trunk duct size as branch ducts are added Has the advantage of saving material and keeping the same pressure from one end of the duct system to the other

THE REDUCING EXTENDED PLENUM SYSTEM Living Room 9,000 btu (cooling) 18,000 btu (heating) 300 cfm 100 cfm 200 cfm 100 cfm 200 cfm 50 cfm 50 cfm

THE PERIMETER LOOP SYSTEM Well suited for installation in a concrete floor in a colder climate Warm air is in the whole loop when the furnace fan is running Keeps the slab at a more even temperature Provides the same pressure to all outlets

THE PERIMETER LOOP SYSTEM Living Room 9,000 btu (cooling) 18,000 btu (heating) 300 cfm 100 cfm 200 cfm 100 cfm 200 cfm 50 cfm 50 cfm

DUCT MATERIALS Ductwork must meet local codes For years, galvanized sheet metal was used exclusively Other ductwork materials Aluminum Fiberglass ductboard Spiral metal duct Flexible duct

GALVANIZED STEEL DUCT Gauge is the measurement of the thickness of galvanized steel duct The gauge size means how many pieces of that material would need to be stacked together to make a one-inch stack Metal duct can be round, square, or rectangular

JOINING SECTIONS OF GALVANIZED DUCT WITH SLIPS AND DRIVES Drive cleat Slip

JOINING SECTIONS OF GALVANIZED DUCT WITH SLIPS AND DRIVES Ends of drives are bent over to secure

FIBERGLASS DUCT Styles: Flat sheet or round prefabricated cut Duct is normally 1 in. thick with aluminum foil backing Special knives are used to make special cuts to turn duct board into ductwork All duct seams should be stapled and taped

SPIRAL METAL DUCT Used more on large systems Comes in rolls of flat narrow metal Runs can be made at the job site Can be located within the occupied space for a more contemporary look

FLEXIBLE DUCT Comes in sized up to about 24 in. in diameter Some have a reinforced aluminum foil backing Some come with vinyl or foil backing and insulation on it Keep duct runs as short as possible Has more friction loss inside it than metal duct Flex duct should be stretched as tight as possible

Floor Register Return Damper Supply Flexible Duct

COMBINATION DUCT SYSTEMS Metal trunk lines with round branch ducts Metal trunk lines with flexible branch ducts Ductboard trunk lines with round metal branch ducts Ductboard trunk lines with flexible branch ducts Round metal duct with round metal branch ducts Round metal trunk lines with flexible branch ducts

DUCT AIR MOVEMENT Branch ducts are fastened to the main trunk by a takeoff-fitting The takeoff encourages the air moving the duct to enter the takeoff to the branch duct Air moving in the duct has inertia, meaning it wants to move in a straight line Using turning vanes will improve the air-flow around corners

Main supply duct Takeoff fitting

BALANCING DAMPERS Used to balance the air in various parts of the system Dampers should be located as close as practical to the trunk line The trunk is the place to balance airflow Handles allow the dampers to be turned at an angle to the airstream to slow the air down

Balancing damper in the closed position Branch duct Balancing damper in the closed position Damper in the open position

DUCT INSULATION A 15°F temperature difference from the inside of the duct to the outside of the duct is considered the maximum difference allowed before insulation is necessary Metal duct can be insulated on the outside and on the inside The insulation is joined by lapping it, stapling it, and taping it

BLENDING THE CONDITIONED AIR WITH ROOM AIR When possible, air should be directed on the walls The diffuser spreads the air to the desired air pattern Cool air distributes better from the ceiling Place diffusers next to the outside walls How far the air will be blown from the diffuser into the room depends on the air pressure behind the diffuser and the style of the diffuser blades

THE RETURN AIR DUCT SYSTEM Individual return air system will give the most positive return air The return air duct is normally sized slightly larger than the supply duct Central return systems are usually satisfactory for a one-level residence A path must be provided for the air to return to the central return The return air grille should be around an elbow from the furnace

Central Return Supply plenum Return plenum One central return grill in the common area

INDIVIDUAL RETURN AIR SYSTEM

SIZING DUCT FOR MOVING AIR Friction loss in ductwork is due to the actual rubbing action of the air against the side of the duct and the turbulence of the air rubbing against itself while moving down the duct The smoother the duct’s interior surface is, the less friction there is The slower the air is moving, the less friction there will be Each foot of duct offers a known resistance to airflow

MEASURING AIR MOVEMENT FOR BALANCING Air balancing is accomplished by measuring the air leaving each register Measuring velocity of the duct in a cross section of the duct Determine the cfm by using the formula: CFM = area in square feet x velocity in feet per minute

Cross-sectional area = 1 ft x 1 ft = 12” x 12” = 144 square inches = 144 in2 / 144 in2 = 1ft2 1 foot Average air velocity is 400 fpm 1 foot Air Volume (cfm) = 400 ft/min x 1ft2 = 400 cfm

Cross-sectional area = 18” x 18” = 324 in2 324 in2 / 144 in2 = 2.25ft2 Average air velocity is 400 fpm 18” Air Volume (cfm) = 400 ft/min x 2.25ft2 = 900 cfm

THE AIR FRICTION CHART Used by system designers to size ductwork and duct systems Gives recommended duct sized and velocities for optimum performance Can be used to troubleshoot airflow problems Pressure drops in duct fittings have equivalent lengths All lengths and equivalent lengths are added together to achieve the total

RESIDENTIAL DUCT SYSTEM A 6-in. round duct delivers 100 cfm to the space An 8-in. round duct delivers 200 cfm to the space Common duct problems Excessively long flexible duct runs Disconnected duct runs Closed dampers Collapsed flexible duct Loose insulation in the duct Blocked grills and/or registers

COMMERCIAL DUCT SYSTEMS Each area has specifications regarding the required amount of airflow Certified testing and balancing company to verify airflow Flow hoods measure air volume at supply registers Total airflow can be measured at the main duct Common problems include dirty filters, partially closed dampers, and incorrect fan rotation

SUMMARY - 1 Forced air systems use the same air over and over Fresh air enters the structure by infiltration Forced air systems deliver the correct quantity of conditioned air to the occupied space Different spaces require different air quantities Forced air systems are made up of the blower, supply duct system, return air system and supply registers or grilles

SUMMARY - 2 Typically, 400 cfm of air must be moved per minute per ton of air conditioning Pressure in the ductwork is measured in inches of water column (in. W.C) Static pressure plus velocity pressure equals total pressure Air volume in cfm can be calculated by multiplying the air velocity by the cross-sectional area of the duct in square feet

SUMMARY - 3 Propeller fans are used in exhaust fan and condenser fan applications and can handle large volumes of air at low pressure differentials Centrifugal blowers are used in duct systems Motor drives can be direct or belt driven assemblies The supply duct system can be configured as a plenum, extended plenum, reducing extended plenum or perimeter loop system

SUMMARY - 4 Duct systems can be made of galvanized metal, aluminum, fiberglass duct board, spiral metal, flexible duct or a combination of different materials Branch ducts deliver the proper amount of air to remote locations in the structures Balancing dampers are used to help ensure proper airflow to the remote locations The return air system can be configured as a central or individual return air system

SUMMARY - 5 Friction in the duct slows the air flowing in it Slower air experiences less friction Air balancing ensures the proper amount of air is delivered to each supply register CFM = velocity x cross sectional area The friction chart is used to properly size duct systems