T.A Nouf Alshareef KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 False colour scanning.

Slides:



Advertisements
Similar presentations
Gel Filtration Gel permeation chromatography Size exclusion chromatography Separation of molecules on the basis of size (and shape)
Advertisements

BIOCHEMISTRY EXPERIMENT PProfessor: Sheng Zhao ( 赵晟 ) WWeb for lecture slides : E /QQ /MSN/gchat:
Size Exclusion Chromatography
Foundation GPC Training Course Theory. Nomenclature Gel Permeation ChromatographyGPC Size Exclusion ChromatographySEC Gel Filtration ChromatographyGFC.
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
Separation of molecules and determination of there molecular weight by gel filtration chromatography. Experiment 7 BCH 333.
Chromatography for Protein purification 1
Ion Exchange Laboratory. Today’s Schedule Pre-lab discussion Ion Exchange and Spectrophotometer Ion exchange experiment.
Size-exclusion chromatography (SEC) Gel permeation chromatography (GPC) Gel Filtration Chromatography (GFC)
1. 2  A form of “partition chromatography”.  Stationary phase is a porous gelatinous matrix (in the form of beads).  Sample components enter pores.
Column Chromatography. Types of columns: 1- Gravity Columns: The mobile phase move through the stationary phase by gravity force. 2- Flash Columns (Air.
HPLC when GC won’t cut it!!!. Types of HPLC Reverse-phase (water/MeOH-soluble) Normal Phase (very polar) Adsorption (very non-polar) Ion-Exchange (ionic)
Salting out is a method of separating proteins based on the principle that proteins are less soluble at high salt concentrations. The salt concentration.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Gel Filtration Chromatography.
Ion Exchange Chromatography. Cation exchangers They contain immobilized anionic groups that bind to cations. e.g. a matrix with carboxymethyl group(CM)
Separation of proteins by ion exchange chromatography
In the name of god.
Chromatography Desalting and Affinity. Chromatography Technique to separate components of a mixture by passing them through a matrix. –A solvent is used.
Chemistry 4010 Lab It’s all about PROTEINS… It’s all about PROTEINS…
Gel filtration chromatography y/college/voet/ /animat ed_figures/ch05/f5-6.html.
Chapter 4-1 Chromatography
Types of Mechanism in the Chromatography
Magnet Analytical Chemistry Unit 4
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
BIOCHEMICAL METHODS USED IN PROTEN PURIFICATION AND CHARACTERIZATION
Factors affecting electrophoresis The electric field ·       Voltage. If the separation of the electrodes is d (cm) and the potential difference.
GF v03 Aug Gel Filtration. GF v03 Aug Gel filtration What is gel filtration and why use it? Some typical results Why and when to choose.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
Principle of separation
HPLC.
Adsorption Chromatography 1Dr. Nikhat Siddiqi. Adsorption chromatography refers to the use of a stationary phase or support such an ion-exchange resin,
Size Exclusion Chromatography *
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
Introduction to Instrumental Analysis - Chromatography
Size-exclusion Chromatography prof. aza Department of Pharmacy, Andalas University STIFI Perintis, Padang STIFAR, Pekan Baru STIFI Bhakti Pertiwi, Palembang.
Analytical biochemistry lab KAU-biochemistry dep. L. Nouf Alshareef
T.A Nouf Alshareef KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012
Ion exchange chromatography
GEL FILTRATION CHROMATOGRAPHY Size Exclusion Chromatography
Food Analysis Lecture 18 (03/27/2012) Basic Principles of Chromatography (3) Qingrong Huang Department of Food Science Read Material: Chapter 27, page.
BY G.SHRAVANI ION EXCHANGE AND GEL PERMEATI ON CHROMATOGRAPHY 1G.SHRAVANI.
Tutorial 09 Overview of other chromatographic methods 1.
Purification of immunoglubin by ion exchange chromatography Bahiya Osrah
Chromatography PlanarColumn Paper TLC (Thin layer chromatography)
Principles of chromatography
KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 T.A Nouf Alshareef
SIZE EXCLUSION CHROMATOGRAPHY
Size exclusion Chromatography
Tymoczko • Berg • Stryer © 2015 W. H. Freeman and Company
 Laboratory technique for the Separation of mixtures  Chroma -"color" and graphein - "to write”.  Colour bands - separation of individual compounds.
CHROMATOGRAPHY.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Chromatography 1 Lecture 10 An introduction. What is CHROMATOGRAPHY ? Chromato g raphy.
BCH BIOCHEMICAL METHODS (2 UNITS) DR AKINLOYE’S ASPECT
Lecture 2: Introduction to Chromatography and Size- Exclusion Chromatography Yaj.
Why Do We Analyze Proteins?
LU 3: Separation Technique (P2)
Chapter 4-3 Chromatography Gel Chromatography Dr Gihan Gawish.
Gel Filtration Chromatography.
Size Exclusion Chromatography (SEC)
Biophysical Tools '04 - Chromatography
Separation of Molecules by Ion Exchange Chromatography
Gel Filtration Chromatography.
Separation of Molecules by Ion Exchange Chromatography
High-Performance Liquid Chromatography
M.S COLLEGE OF ARTS, SCIENCE, COMMERCE AND B.M.S
High-Performance Liquid Chromatography
Presentation transcript:

T.A Nouf Alshareef KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 False colour scanning electron micrograph of Sephadex beads.

Background Gel-filtration is liquid chromatography which separates molecules according to their size. Also known as: Size-Exclusion Chromatography (SEC) Gel - Permeation Chromatography Molecular sieve chromatography Used in separation of macromolecules such as proteins, peptides, nucleic acids and carbohydrates. Used in separation of macromolecules such as proteins, peptides, nucleic acids and carbohydrates.

Stationary phase Is gel beads which contain pores of specific size. Usually gel is polysaccharides (dextran) or other polar polymers formulated into small beads Theses beads varying in degrees of cross-linking of the polysaccharide within the bead. Beads allowing smaller molecules to pass through their pores, while larger molecules are excluded.

Principle: Sample pass through a column packed with a swollen gel. Separating of molecules occurs according to molecular weight: Separating of molecules occurs according to molecular weight: - Large molecules (that are larger than the largest pore): - Smaller molecules (the are retained because) Smaller molecules penetrate the pores to different degrees depends on their size molecules are eluted in order of decreasing size. So, Gel-filtration works opposite to sieve. can’t penetrate gel pores move around the beads excluded from gel pores pass through the column quickly elute first

Important parameters: Exclusion volume or void volume (Vo): volume between gel beads (Vo = elution volume of large molecules they do not enter the pores) Internal pore volume Vi: volume inside the beads. (Vi = elution volume of small molecules) Elution volume (Ve): volume required to elute a particular molecule Total volume (Vt ): is total volume of mobile phase in the column Vt = Vi+Vo

Partition coefficient (Kd) Kd: is the partition coefficient for solute, (the extent to which the molecules can penetrate the pores in stationary phase) its value range between 0 and 1 Kd = Ve – Vo Vi it is difficult to measure Vi precisely, the equation modified to determine available part of the resin (Kav). Kav = Ve – Vo Vt – Vo Sample components (solutes) are easily separated if their (Kav) value different from each other. (Vt = π r².h)

Types of stationary phase The media used for gel exclusion chromatography are: – dextran (Sephadex™), – polyacrylamide (Bio-Gel P™) – dextran-polyacrylamide (Sephacryl™) – agarose (Sepharose™ and BioGel A™) Sephadex G-25 is most common gel used in gel-filtration chro. Each is available with a different ranges of pore size in the beads, permitting separation of macromolecules of different size.

Different types of matrix forming stationary phase: It is a strongly hydrophilic polymer, and swells in water before a column is prepared, the gel must be full hydrated. dextran Cross-linked dextran polymer (Sephadex G-10 to G-200) They are hydrophilic but are chemically more stable than dextran gels. polyacrylamide Cross-linked polyacrylamide (Biogel P-2 to G-300) They are also hydrophilic but are sold in the swollen form. Agarose Agarose-the largest pore size The polyacrylamide provide a three-dimensional structure which supports the interstitial agarose gel. polyacrylamide agarose Mixed gels of polyacrylamide and agarose (Ultragel) - Controlled-pore glass beads can use as porous gel

Sephadex-25 It is an inert, bead-formed, cross-linked dexran (polymer of glucose). Sephadex beads are porous, Molecules larger than largest pores cannot enter the gel and are eluted first, Smaller molecules enter the beads and are retard. Sephadex G-25 exclude all molecules with a molecular weight greater than 5000, thereby eluting them first.

Advantages of gel filtration Reliable and simple Little equipment is required The procedures are straight forward Good separation and yields

Application of gel-filtration: Used in: Separate molecules of different sizes (biological molecules) Determination of the relative molecular mass: using a calibration curve prepared from the elution volumes of several reference substances of known relative molecular mass. Desalting or buffer exchange: The removal of solutes of low relative molecular mass from preparations of macromolecules.

Lab Practice In this lab, you will separate a mixture of blue dextran and cobalt chloride molecules through a gel-filtration column collecting elutes (Run-off), and calibrating a curve to show how the column separates molecules by molecular weight. Then, you will use the calibration curve to identify the molecular weights of the proteins.

Blue dextran: is a glucose polymer with high M.wt (M.wt = daltons) It is too large and can’t get into the beads and therefore excluded from the gel (Kd=0), and pass the column in the void volume (space between gel beads). Blue dextran is often used as a marker to measured void volume. Cobalt chloride: low molecular weight (Small molecule) is freely accessible to the gel particles (Kd=1), and elute at a volume equal to Vt

Both molecules (Blue dextran & CoCl 2.6H 2 O) are colored so the progress of the filtration can be followed by observing the separation of the colored bands. Fraction analysis: The completed fraction is then analyzed by measuring the extinction of each fraction at 625 nm and 510 nm Blue dextran ʎ max = 625 nm CoCl 2.6H 2 O ʎ max = 510 nm

Chemicals & other material: Sephadex G25 Blue dextran in saline Cobalt chloride in saline Sodium chloride (0.9 %), (Saline)

Procedure: Number 15 test tubes and arrange them in order on a rack. Prepare the gel bead column: Column (12 cm) is filled with semisolid (Swollen) gel beads of Sephadex G-25 [Sephadex gel soaked in the elution buffer 3-4 hrs]. Be gentle; do not allow gaps or bubbles to form. Allow small amount of saline to flow through the column between additions of beads (help the beads to settle) Equilibrate the column with saline by passing about 10 ml of saline through the column beads after it has completely settled.

It is important that the gel should be homogenous, free from bubbles, free from crack, and free from spaces between the walls. And it should be covered by the liquid "mobile phase" all the time. Avoid stirring up the top of the column bead when adding saline or samples, as this will give poor resolutions of the samples.

Drain saline solution down (keep1 mm of buffer above the gel) before adding the sample mixture Carefully add the sample mixture to the top of the column using a pasture pipette. (do not stir up the top of the gel) Turn off the stopcock to allow the mixture to enter the gel beads. Then add saline solution to the top, filling the space at the top of the column.

Collect the fractions (3 ml/tube) beginning with tube # 1 (Early fractions contain large molecules while later fractions contain smaller ones). Measure the absorbance spectrum of each fravtion in order to identify each molecule (Blue dextran at 625 nm, CoCl2.6H 2 O at 510 nm).

Cobalt chloride Blue dextran Sephadex G25 Sodium chloride (0.9%), (Saline)

Large molecule Small molecule

Results: Tube No. Volume fraction (ml) Absorbance at 510 nm (Blue dextran) Absorbance at 625 nm (Cobalt chloride )