Www.le.ac.uk Flow Cytometry. Applications FRET- protein interaction Membrane protein expression Intracellular protein expression Cell viability Ca 2+

Slides:



Advertisements
Similar presentations
Research Techniques Made Simple: Flow Cytometry Richard R
Advertisements

Introduction to Flow Cytometry
1 2 3 * Flow = cells in motion * Cyto = cell * Metry = measure * Measuring properties of cells while in a fluid stream * Flow Sorting * Sorting (separating)
What is Flow Cytometry? Introduction to Flow Cytometry
What is Flow Cytometry? Flow Cytometry uic Introduction to Flow Cytometry IGC Workshop Multicolor Flow Cytometry IGC – April 28, 2010 Adapted from Holden.
Intro to Flow Cytometry James Marvin Director, Flow Cytometry Core Facility University of Utah Health Sciences Center Office Lab
Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.
ACQUISITION RATES EFFECT ON MULTIPARAMETRIC RARE EVENT ANALYSIS : AN INSTRUMENT COMPARISON John Tigges, Vasilis Toxavidis, Heidi Mariani Beth Israel Deaconess.
CHAPTER 37 MLAB 1415 HEMATOLOGY JOANNA ELLIS, MLS(ASCP) Optical Light Scatter and Flow Cytometry.
Introduction To Flow Cytometry:
Advancements in FACS analyzers optical design leads to greater functionality and a smaller footprint. INTRODUCTION In the past decade, instrumentation.
COMPENSATION By: Ronald Mathieu. Compensation Why do we need compensation? –1) Because of long emission spectrum of dyes like FITC and PE.
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
Introduction to the Principles of Flow Cytometry
Overview What is flow cytometry? Development of flow cytometry Components of Flow Typical applications Flow data.
Flow Cytometry Basics James Marvin Director, Flow Cytometry Core Facility University of Utah Health Sciences Center Office Lab
FACSCalibur Training General Information The FACSCalibur is a useful analysis tool. The instrument has 2 lasers- 488 (primary) and 633 (secondary) that.
Introduction to the LSR II and FACSDiva 6.0 Software
Introduction to Flow Cytometry IGC Workshop April 27-30, 2010 General Programme TimeTutorialRoomSpeaker Day 1 9h30-10h45Fundamentals of Flow CytometryIoniansRui.
Basics of Flow Cytometry Holden Maecker. Outline Definitions, what can be measured by flow cytometry Fluidics: Sheath and sample streams, flow cells,
These particles have something in common
Introduction to Flow Cytometry
PPT 206 Instrumentation, Measurement and Control SEM 2 (2012/2013) Dr. Hayder Kh. Q. Ali 1.
Applications of flow cytometry in basic immunology Generation and characterization of DC Assays for T cell activation –Cell proliferation – Cell division.
FLOW CYTOMETRY Flow cytometry is a laser-based, biophysical technology employed in  cell counting,  cell sorting,  biomarker detection protein engineering.
Supplemental Figure 1 A. EpCAM Gating Strategy Top Row: Histogram showing unstained BT474 cells with low fluorescent intensity of the EpCAM specific PE.
Flourescence Activated Cell Sorting
Practical molecular biology PD Dr. Alexei Gratchev Prof. Dr. Julia Kzhyshkowska Prof. Dr. Wolfgang Kaminski.
Cell viability studies Sepideh Khoshnevis. The Goal To distinguish live cells from dead and apoptotic cells in order to calculate the the percentage of.
Flow Cytometry at Boston University Medical Campus Introduction to some methods that we offer Yan Deng (X4-5225), Gerald Denis (X4-1371),
Introduction To Flow Cytometry By Noha Kamel. Flow cytometry is a method of measuring multiple physical and chemical characteristics of particles by optical.
Basic Principles in Flow Cytometry
 Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid.
Basic Principles, Instrumentation, and Practices
Flow Cytometry Principles & practice of “Fluorescence Spectroscopy in Biological Diagnosis & Research” Dr.Hekmatimoghaddam Assistant professor of pathology.
FLOW CYTOMETRY  Definition: Measuring properties of cell as they flow in a fluid suspension across an illuminated light path.
Laser Flow Cytometry Forward Scatter indicates size Forward Scatter.
Flow Cytometry Basic Training. What Is Flow Cytometry? Flow ~ cells in motion Cyto ~ cell Metry ~ measure Measuring properties of cells while in a fluid.
Flow Cytometry (FCM) Yun-Ju Lee September 13, 2002.
1 Flow Cytometry in the Clinical Laboratory Patricia Aoun, M.D., M. P. H. Jean Bailey, MT-ASCP Kellie Neth, MT-ASCP The Nebraska Medical Center.
2015 היחידה להפרדת תאים ד"ר דבי איצקוביץ'
Flow Cytometry Becton Dickinson Asia Limited Company.
FLOW CYTOMETRY Not as scary as it sounds!. A BIT OF HOUSEKEEPING…  About me!  About you  Institute  Prior knowledge  Core facility.
23W!~ Anti-vWF Immunofluorescence in Mouse Brain Minjung Choi, Katie Stockdale, James O. McNamara Department of Internal Medicine, The University of Iowa,
Multi-parameter Flow Cytometry: available dyes and combined usage Martin R. Goodier Department of Immunology Imperial College London.
Fluorescence and Fluorochromes Peter O’Toole Tel:
Dotplots CD3 CD4 Allow for visualizing relationship between two different parameters that is not apparent by histogram analysis.
Fluorescence and Fluorochromes Peter O’Toole Tel:
Cytoskeleton Lab 2: The Effects of Cytochalasin B on the Actin Cytoskeleton & Cell Viability in Mouse Fibroblast Cells.
FACSCalibur Training General Information
بسم الله الرحمن الرحیم.
Flow Cytometry Halima Moncrieffe, University College London, UK IL-17
Flowcytometry.
Flow Cytometry FACS (Fluorescence-Activated Cell Sorter)
TRENDS IN LABORATORY TESTING
FLOWCYTOMETRY.
Default LSR II Configuration BLUE 488nm PerCP, PerCP-Cy5.5, PE-Cy5
Core Facility Operator
Anti-vWF Immunofluorescence in Mouse Brain
Spectral Flow Cytometry
Some Basic Physics & Optics
Flow cytometric analysis of putative progenitor cells.
The Art of Flow Cytometry
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
1. Use the brightest fluorophores available. Brightness Expression
Immunofluorescence Microscopy cell Biology Ptactical 3
S.varasteh 10/11/2012.
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Presentation transcript:

Flow Cytometry

Applications FRET- protein interaction Membrane protein expression Intracellular protein expression Cell viability Ca 2+ flux Cell cycle analysis Cell sorting (FACs) Intracellular pH RNA content Cell proliferation Production of intracellular oxidative species

General principles Fluidics Optics Detection Output

Fluidics Sample uptake –Older machines under vacuum –Newer machines inject sample –Under high pressure Injected into centre of a flow chamber Buffer or dH2O (Sheath fluid) flow round the sample causing cells to form single line –Hydrodynamic focusing

Optics Samples move through path of laser as single cells –Different types of laser Violet laser – 405nm Blue laser – 488nm Yellow laser – 561nm Red laser – 635nm –Numbers represent wavelengths at which the lasers excite Fluorophore's –The blue laser is also used to measure size (forward scatter) and granularity of cells (side scatter)

Optics continued… Laser light reflects off cells and reaches dichroic mirrors –Mirrors allow certain wavelengths through and all other wavelength's are reflected to detectors –There are three types of filter Long pass – allows light through over a certain wavelength –E.g. 750LP- light >750 Short pass – allows light through below a certain wavelength –E.g. 560SP- light <560nm Bandpass – allows light through between certain wavelengths –E.g. 530/20 – light between 520 and 540nm The fluorophore’s you are able to use are dependent on the filters you have – and their emission wavelength

Optics continued…

Detection Detected light hits photomultiplier tubes (PMTs) Creates voltage pulse proportional to amount of light they receive –E.g. small cell, low forward scatter, small pulse –Large cell, high forward scatter, large pulse Voltages from fluorescent signals converted to numerical values

Output Data collected represented in graphical format Histogram, dot plot, contours…

Important considerations Fluorophore’s / Lasers Location of molecule of interest Controls –Isotype –Secondary control –Positive Compensation Gating Method

Fluorophore’s APC-H7 APC-Cy7 APC-Vio770 APC PerCP-Cy5.5 PerCP PE-Vio770 PE-Cy7 PE-Cy5.5 PE-Cy5 PE-Texas Red PE FITC Pacific Orange VioGreen AmCyan Pacific Blue VioBlue PI Alexa Fluors’s Lots more

Fluorophore’s continued… The Fluorophore's you can use depend on your lasers and filters E.g. FITC (green) Excited 495nm, emission 519nm –Stokes shift –Use 488 blue laser and 530/40 band pass filter

Fluorophore’s

Controls-1 Isotype –Antibody from the same species as host and same antibody isotype E.g. we have a mouse IgG2a anti-CD14-FITC antibody so an isotype would be mouse IgG2a-FITC, usually used at same concentration under same conditions Allow a measure of non-specific binding

Controls-2 Sometimes primary antibody to molecule of interest isn’t labelled Have to use labelled secondary antibody to detect primary Standard procedure to use a secondary only sample as control

Controls-3 Positive controls –Need to know if antibody works –Optimum concentration of primary antibody –Best method to stain

Compensation If using more than one fluorophore Needed if Fluorophore's excited by same laser Fluorophore’s have emission spectra –Values given are peak emission values In the real world emission spectra are graded

Compensation continued… Some emission spectra of fluorophore’s overlap Means that they will fluoresce in that channel If no compensation than you would not know if your result is real Most new machines now have automatic settings

Where is your molecule of interest? Membrane –Staining relatively simple no fixation or permeabilisation required Cytosol/organelle –Permeabilisation and fixation required Protein? DNA? Phospholipid? Antibodies need to be able to enter a cell Some dyes don’t e.g. Calcein

Methods Each lab has standard methods Usually results do not differ much between similar methods However, different methods need to be used if protein intra/extracellular –Permeabilisation Acetone / Tween / Triton –Fixation Methanol / PFA / Formaldehyde Also need to lyse RBCs if using whole blood

Example Protein expressed on surface of endothelial cells Cultured Ea.Hy926 cells –Know contain protein by western blotting

Conventional method Resuspend cells in buffer Stain 30min primary antibody Stain 30min secondary antibody Make up to 1ml in buffer Run on flow cytometer

Adjusted method Cells fixed for 5min in methanol Resuspended in buffer Stained as before

Gating Gates can be used: –To select populations –To measure the level of protein expression E.g. in whole blood can gate monocytes based on size and granularity Granulocytes Monocytes Lymphocytes

Gating continued… Can set histogram to identify molecule of interest on gated cells

Gating continued… When measuring level of protein expression etc. the isotype is usually set to 2% To take into account cells that express the molecule of interest weakly

Stats Can get a number of statistics from the data Most useful –Percentage of positive cells –Median fluorescence Intensity and spread of distribution

Worked example

PE

FITC

Compensation

Isotype 0h 4h 8h

Facilities in the department Currently 2 flow cytometers Both Beckman Coulter –Gallios –ADP Cyan MUST BE TRAINED AND HAVE INDUCTION FROM TINA JAMES BEFORE YOU START USING EITHER MACHINE!!

Gallios 3 lasers, 488 (blue), 638 (red), 405 (violet) Filters allow up 10 colours –FL1 525/40 bp –FL2 575/30 bp –FL3 620/30 bp –FL4 695/30 bp –FL5 755 LP lp –FL6 450/40 bp –FL7 550/40 bp –FL8 660/20 bp –FL9 725/20 bp –FL lp Blue Violet Red Brand new Carousel so can load and leave Kaluza software, easy to use

ADP Cyan 3 lasers, 488 (blue), 405 (violet) and 635 (red) –Although red filter temperamental and not always aligned Filters allow up 9 colours –FL1 530/40 bp –FL2 575/25 bp –FL3 613/20 bp –FL4 680/30 bp –FL5 750 LP –FL6 450/50 bp –FL7 530/40 bp –FL8 665/20 bp –FL9750 LP Blue Violet Red No carousel so have to manually load samples Software easy to use and transferable to work computer Can add gates, analyse and set up histograms after running samples

Documentation Keeney, M., et al., Isotype controls in the analysis of lymphocytes and CD34+ stem and progenitor cells by flow cytometry - Time to let go! Cytometry, (6): p discovery/products-and-services/flow-cytometry/flow-cytometers/cyan- adp-analyzer/index.htm - For CYAN ADP guide Flow Cytometry- a basic introduction, Michael G. Ormerod Most of the companies have information on flow cytometry I also have 4/5 power points and training manuals from Beckman Coulter