PGRIS: Towards portable Compton Camera Imaging

Slides:



Advertisements
Similar presentations
Applications of Nuclear Physics Applications of Nuclear Physics (Instrumentation) Dr Andy Boston Frontiers of gamma-ray spectroscopy.
Advertisements

M. JONES 1, A.J. Boston 1, H.C. Boston 1, R.J. Cooper 1, M.R. Dimmock 1, L.J. Harkness 1 D.S. Judson 1 P.J. Nolan 1, D.C. Oxley 1, B. Pietras 1 M.J. Joyce.
M. Jones, A. Boston, M. Chartier, B. McGuirk, P. Nolan, R.D. Page, P. Pusa, D. Seddon, J. Thornhill, D. Wells and the ALPHA collaboration Department of.
D S Judson UNTF Forum Salford. Outline The Compton imaging process The PORGAMRAYS project What is it? How does it work? Detector description Spectroscopic.
Advanced GAmma Tracking Array
CdZnTe Energy Resolving Array Detectors Paul Seller
Semiconductor detectors for Compton imaging in nuclear medicine
Detection of Gamma-Rays and Energetic Particles
SmartPET: A Small Animal PET Demonstrator using HyperPure germanium Planar Detectors R. Cooper 1 st year PhD Student
Compton Identification Within Single ‘Pixels’ D. Scraggs, A. Boston, H. Boston, R. Cooper, J. Cresswell, A. Grint, A. Mather, P. Nolan University of Liverpool.
Long Fiber-Optic Perimeter Sensor: Intrusion Detection W. Tim Snider, Faculty Advisor: Dr. Christi K. Madsen Texas A&M Department of Electrical and Computer.
First detector and DAQ test results from the TEDA beamline Matt Andrew, Mike Hadmack, Bryce Jacobson, Gary Varner University of Hawaii Experience from.
Sept. 18, 2008SLUO 2008 Annual Meeting Detector R&D at KIPAC Hiro Tajima Kavli InStitute of Particle Astrophysics and Cosmology.
Simulations with MEGAlib Jau-Shian Liang Department of Physics, NTHU / SSL, UCB 2007/05/15.
Anthony Sweeney Position Sensitive Detectors 9 Aberystwyth 2011.
Paul Sellin Detector Research at the University of Surrey Dr Paul Sellin Centre for Nuclear and Radiation Physics Department of Physics University of Surrey,
Bump Bonding Requirements for Nuclear Physics Ian Lazarus Nuclear Physics Group STFC Daresbury Laboratory.
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
Compton Camera development for the imaging of high energy gamma rays 1 Martin Jones UNTF 2010 Salford – April 14 th Martin.
M. Labiche - INTAG workshop GSI May Se - D prototype for the focal plane of the PRISMA spectrometer (Task4) Digitisers for SAGE & LISA (task1)
X-ray data acquisition systems for Airport Security J M Homer Electron Tubes Ltd.
SPECT imaging with semiconductor detectors
A Readout ASIC for CZT Detectors
R&T télescope APC1INFIERI meeting – 15 juillet 2014 DSSD detectors development for a space Compton telescope P. Laurent, Y. Dolgorouky, M. Khalil,
Imaging of Ra-223 with a small- pixel CdTe detector: potential for improved image quantification for radionuclide dosimetry James Scuffham 1,2 Silvia Pani.
A Front End and Readout System for PET Overview: –Requirements –Block Diagram –Details William W. Moses Lawrence Berkeley National Laboratory Department.
Development of an ASIC for reading out CCDS at the vertex detector of the International Linear Collider Presenter: Peter Murray ASIC Design Group Science.
Performance limits of a 55  m pixel CdTe detector G.Pellegrini, M. Lozano, R. Martinez, M. Ullan Centro Nacional de Microelectronica, Barcelona, 08193,
Parallel Data Acquisition Systems for a Compton Camera
Pedro Arce Introducción a GEANT4 1 GAMOS tutorial Compton Camera Exercises
Effects of Surrounding Materials on Proton-Induced Energy Deposition in Large Silicon Diode Arrays Christina L. Howe 1, Robert A. Weller 1, Robert A. Reed.
Pixellated CZT high-energy X-ray instrument
A 128-channel event-driven readout ASIC for the R 3 B Tracker TWEPP 2015, Lisbon Lawrence Jones ASIC Design Group Science and Technology Facilities Council.
ERIK FRÖJDH – ESR 2 Mid Sweden University, CERN 14th October 20132nd ARDENT Workshop1.
Observational techniques meeting #15
Development of a Segmented Planar Germanium Imaging Detector
JRA-1 ISRSI Consortium Meeting Perugia, INAF/IASF (BO,PA)
HEXITEC ASIC – A Pixellated Readout Chip for CZT Detectors Lawrence Jones ASIC Design Group Science and Technology Facilities Council Rutherford Appleton.
Electron tracking Compton camera NASA/WMAP Science Team  -PIC We report on an improvement on data acquisition for a Time Projection Chamber (TPC) based.
Ciemat Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas Daniel Cano-Ott, DAQ meeting in Huelva, July 18 th and 19 th A new flash.
Compton imaging with the PorGamRays Detector D S Judson Imaging 2010, Stockholm, 8 th -11 th June 2010.
Active Pixel Sensors in Medical and Biologi The application of Large Area Active Pixel Sensor (LAS) to high resolution Nuclear Medicine imaging Bob Ott.
3D Position Sensitive CdZnTe Spectrometers Using 3 rd -Generation VAS/TAT Readout Electronics Feng Zhang, Zhong He, Glenn F. Knoll, David K. Wehe, James.
ZEPLIN III Position Sensitivity PSD7, 12 th to 17 th September 2005, Liverpool, UK Alexandre Lindote LIP - Coimbra, Portugal On behalf of the ZEPLIN/UKDM.
Room-Temperature Semiconductors: From concepts to applications Zhong He Nuclear Engineering and Radiological Sciences Department The University of Michigan,
Andy Boston Imaging devices for medicine and security.
Comparison of a CCD and the Vanilla CMOS APS for Soft X-ray Diffraction Graeme Stewart a, R. Bates a, A. Blue a, A. Clark c, S. Dhesi b, D. Maneuski a,
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
AIDA: introduction Advanced Implantation Detector Array (AIDA) UK collaboration: University of Edinburgh, University of Liverpool, STFC Daresbury Laboratory.
Advanced Gamma Tracking Array Andy Boston The Advanced Gamma Tracking Array
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
Page Detector and Electronics R&D for picosecond resolution, single photon detection and imaging J.S. MilnesPhotek Ltd T.M. ConneelyUniversity.
MOHAMAD KHALIL APC LABORATORY PARIS 17/06/2013 DSSD and SSD Simulation with Silvaco.
Characterisation of a pixellated CsI detector for the Distinguish Project. 1 Martin Jones The University of Liverpool
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
Development of a Compton Camera for online range monitoring
M. C. Veale1, S. J. Bell1,2, D. D. Duarte1,2, M. J. French1, M
Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
Thomas Woodroof Dr Jonathan Bridge, School of Engineering
WPOL Wide field camera with POLarimetry
SIGMA: a detector for γ-ray spectroscopy & imaging Dr Laura AGATA/GRETINA Collaboration Meeting
Application of Nuclear Physics
AIDA: introduction Advanced Implantation Detector Array (AIDA)
Preliminary Compton Imaging results of the AGATA C001 detector
Background Reduction for Quantitative Gamma-ray Imaging with the Electron-Tracking Compton Camera in High Dose Areas May 26th, PS10A-10 T. Mizumoto,
Presented at 2016 IEEE Nuclear Science Symposium - N28-32
JSC “Institute in Physical-Technical problems”
ME instrument and in-orbit performance
Why silicon detectors? Main characteristics of silicon detectors:
Implantation detector as active stopper Rakesh Kumar, P. Doornenbal, I
Presentation transcript:

PGRIS: Towards portable Compton Camera Imaging Samantha Colosimo∗, Andrew Boston∗, Helen Boston∗, Laura Harkness-Brennan∗, Daniel Judson∗, Ian Lazurus†, Paul Nolan∗, Paul Seller‡, John Simpson†, and Matthew Veale‡ ∗Department of Physics, University of Liverpool, Liverpool L69 7ZE, UK †STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD, UK ‡STFC Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot OX11 0QX, UK

Overview Portable Imaging and Spectroscopy Compton Camera Principle PorGamRays Project Image Reconstruction The PGRIS detectors and ASICs Future characterization work PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Portable Imaging Aim – To create a portable gamma-ray spectroscopy and imaging system for decommissioning, security, and medical applications. System will be: Handheld and battery operated Able to work at room temperature Capable of isotope identification Detect sources in 3D space Waste storage at Nuclear Decommissioning Authority. http://www.nda.gov.uk PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Portable imaging and spectroscopy Detecting sensors chosen to operate in a modular system – No cooling Need excellent spectroscopic performance. 3D Imaging will be performed based on the Compton camera principle. Radioactive material found quickly, reducing cost, false alarms and search times while increasing cargo throughput Portable imaging and spectroscopy device. PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Compton Camera Principle The Compton camera principle relies on projecting Cones of Response into imaging space. Gamma-ray energy will be deposited in a detector through Compton scattering and then absorbed in a second detector via the photoelectric effect. Cones are projected using the Compton scattering equation. Require a knowledge of energy, position and time. PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Compton Camera The cone axis is determined through the interaction positions in the scatter and absorber detectors. The energy deposited determines θ. From these parameters a cone is reconstructed. θ Source PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Compton Camera From the overlap of multiple cones, the source location can be found. Source PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

PorGamRays The PorGamRays system was designed to prove the possibility of near field imaging with CZT & Si detector based Compton camera1. Original design of CZT – ideal due to wide band gap detector stack with 5 mm separation in a modular design. Spectroscopy and imaging capabilities proven. 33Ba - 357 keV photon = FHWM ~ 20 mm x (mm) y (mm) D.S. Judson et al. Nuclear Instruments and Methods in Physics Research A, 652 (2011), p. 587 PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

PorGamRays 133Ba (356 keV) 57Co (121 keV) x position (mm) x = 95 mm x = 115 mm Measured changes in the source position of 10 mm. Multi source imaging Ba133 (356 keV) and Co57 (151 keV). PorGamRays was limited by the use of NUCAM II ASICS1 available at the time, Limited energy range (up to ~350 keV). Not able to readout multiple channels to account for the charge sharing between segments -> leading to poor energy resolution 133Ba (356 keV) 57Co (121 keV) x = 110, y = 120 mm, x = 130 mm, y =85 mm P. Seller et. al., IEEE Nuclear Symposium Conf. Rec., V6, 3786, ’06 D. Judson at Imaging 2010 PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Developments after PorGamRays Imaging Methods – D. Judson Real time imaging capability has been developed. An iterative reconstruction algorithm has been developed at the Liverpool. New detectors modules New CZT and Si detectors. New ASICs which will increase the energy range and allow for multichannel readout. PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Image Reconstruction Image reconstruction can be performed using both analytical and iterative algorithms (OSEM, MLEM). Analytical reconstruction was employed in the PorGamRays project. The iterative method has been employed on the data. 133Ba: PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Portable Gamma-Ray Imaging Spectrometer - PGRIS PGRIS is being developed to expand the capabilities of the system. Modular design New detector modules (CZT and Si), which will posses an imaging range of 60 keV – 1.5 MeV. Specially developed PGRIS ASICs, which are capable to allow spectroscopy on photon energies ranging from 60 keV to ∼8 MeV. PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

PGRIS Detectors CZT Detectors: Si Detector: Provided by STFC RAL. Ideal for High Resolution gamma-ray spectroscopy 20 x 20 mm detectors 2 mm thick detector, 2x2x2 mm, 8 mm3 voxels. 5 mm thick detector, 5x2x2 mm, 20 mm3 voxels. Si Detector: 20 x 20 mm, 1000 μm thick Manufactured by Micron Semiconductors 100 pixels Image photons down to the 60 keV. Fig. PGRIS 5 mm CZT Detector mounted on daughter card with NUCAM II ASIC PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

PGRIS ASICs Some Functional Specs: Power supply: 3.3V Clock frequency: 32MHz 100 data channels One further channel for timestamp monitoring DC input coupling Leakage current compensation: up to 150nA Selectable gain - input range: 80k or 400k electrons Selectable shaping time: 0.5s to 7.5s - 4bit resolution For every event above an externally defined energy threshold, channel number, amplitude, charge collection time and timestamp are transmitted. The threshold is externally adjustable. The PGRIS ASIC has two outputs: external ADC and internal ADC on daughter cards which can send data to the readout FPGA. Designed for higher energy events, which will improve upon the previous issues with charge sharing. Data from neighbouring channels are also read out as part of the same event. PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Modification of PGRIS motherboard Test and characterize the new CZT detectors, which have been mounted onto NUCAM2 daughter boards. In order to power two CZTs of difference widths, a modification to the motherboard will be made. Detectors require field strength of 4,000 – 5,000 V cm-1. 2 mm ~ 800 - 1000 V 5 mm ~ 2000 - 2,500 V The power supply will need to be changed to power two detectors simultaneously with different bias voltages. PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Next steps Test and characterize the new CZT detectors with radiation -> these are currently mounted onto NUCAM2 daughter boards and awaiting testing. The second stage is to mount these detectors with the purpose built PGRIS ASICs. Test system with new Silicon detector, mounted to PGRIS ASICs. Produce Compton images with the analytical and iterative imaging algorithms. PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

Summary A portable Compton Camera device is being developed at the University of Liverpool. The proof of principle work developed by the PorGamRays system will be improved upon with the use of new detectors and ASIC modules, expanding the capability of the system. Characterisation work will be performed with the new detectors along with the purpose built PGRIS ASICS. PSD10 - 10th International Conference on Position Sensitive Detectors. - University of Surrey Samantha Colosimo, University of Liverpool - 11/09/2014

PGRIS: Towards portable Compton Camera Imaging Samantha Colosimo∗, Andrew Boston∗, Helen Boston∗, Laura Harkness-Brennan∗, Daniel Judson∗, Ian Lazurus†, Paul Nolan∗, Paul Seller‡, John Simpson†, and Matthew Veale‡ ∗Department of Physics, University of Liverpool, Liverpool L69 7ZE, UK †STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD, UK ‡STFC Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot OX11 0QX, UK