Electron cloud measurement in Cu/Al chambers with/without TiN coating at KEKB positron ring 2010.2.23 ILC DR Working Group Meeting Kyo Shibata (KEK)

Similar presentations


Presentation on theme: "Electron cloud measurement in Cu/Al chambers with/without TiN coating at KEKB positron ring 2010.2.23 ILC DR Working Group Meeting Kyo Shibata (KEK)"— Presentation transcript:

1 Electron cloud measurement in Cu/Al chambers with/without TiN coating at KEKB positron ring 2010.2.23 ILC DR Working Group Meeting Kyo Shibata (KEK)

2 Test chambers with/without TiN coating have been installed into KEKB positron ring (Low Energy Ring, LER), and the electron cloud densities in them have been measured. Test chambers (circular duct with a diameter of 94 mm): 1. Copper chamber (Cu, OFC C10100) 2. Copper chamber with TiN coating (Cu+TiN) 3. Aluminum alloy chamber (Al, 5052) 4. Aluminum alloy chamber with TiN coating (Al+TiN) – Thickness of TiN coating : 200 nm 2010/2/232ILC DR Working Group Meeting CuCu + TiNAl + TiN

3 KEKB LER (positron ring) : – Energy : 3.5 GeV – Beam current :  1600 mA – Number of bunch :  1585 (  1 mA/bunch,  10 nC/cunch) – Bunch spacing : 6 ns – Bunch length : 6 mm All test chambers were installed into the same location. – Straight section – Number of Photon : 3  10 12 photons /s/m/mA – Drift space – No solenoid field 2010/2/233ILC DR Working Group Meeting Test chamber (Al) Electron monitor

4 Electron cloud density near the bunch were measured by a electron monitor with RFA. – By selecting high energy electrons, the density near the bunch can be estimated. 2010/2/234ILC DR Working Group Meeting Electron monitor Conceptual drawing of the density measurement

5 Electron cloud density in the bare Al chamber is much larger than that in Cu chamber. TiN coating is effective for both Cu and Al chambers. 2010/2/235ILC DR Working Group Meeting Al Cu Al + TiN Cu + TiN K. Kanazawa