Presentation is loading. Please wait.

Presentation is loading. Please wait.

SLOPES IV – Structure Span OHW ACW Functional Floodplain Span (FFS) Paul R. Wirfs, P.E. Oregon Department of Transportation Engineering & Asset Management.

Similar presentations


Presentation on theme: "SLOPES IV – Structure Span OHW ACW Functional Floodplain Span (FFS) Paul R. Wirfs, P.E. Oregon Department of Transportation Engineering & Asset Management."— Presentation transcript:

1 SLOPES IV – Structure Span OHW ACW Functional Floodplain Span (FFS) Paul R. Wirfs, P.E. Oregon Department of Transportation Engineering & Asset Management Unit Manager

2 SLOPES IV – Structure Span Bridges and Culverts Good Engineering Judgment Streamlined Permitting Option Early Evaluation & Communication

3 SLOPES III Total Scour Elevation Active Channel Width Total Scour Depth

4 BRIDGE SCOUR

5 Total Scour at a Bridge Total Scour Elevation Total Scour Depth Functional Floodplain Span (FFS)

6 Key Terms General Scour Depth ACW Bank Full Width Top of Bank General Scour Elevation OHW Thalweg

7 Functional Floodplain Span Single Span Structure –1.5 x Active Channel Width Multi-Span Structure –2.2 x Active Channel Width

8 General Scour Prism General Scour Depth OHW ACW Functional Floodplain Span (FFS) AB FFS = ACW + A + B General Scour Prism

9 Functional Floodplain Span Single Span Structure –FFS = 1.5 x ACW = ACW + A + B –A+B = 0.5 x ACW Multi-Span Structure –FFS = 2.2 x ACW = ACW + A + B –A+B = 1.2 x ACW

10 Bridge Abutment Protection Required Because: –Abutment Scour not considered –Channel Migration –Foundation on Erodible Materials

11 http://www.oregon.gov/ODOT/HWY/ GEOENVIRONMENTAL/ ftp://ftp.odot.state.or.us/SLOPES_IV Paul R. Wirfs, P.E. Oregon Department of Transportation Engineering & Asset Management Unit Manager 503-986-3526


Download ppt "SLOPES IV – Structure Span OHW ACW Functional Floodplain Span (FFS) Paul R. Wirfs, P.E. Oregon Department of Transportation Engineering & Asset Management."