Presentation is loading. Please wait.

Presentation is loading. Please wait.

Cryomodule prototype Yun He, Dan Sabol, Joe Conway On behalf of Matthias Liepe, Eric Smith, James Sears, Peter Quigley, Tim O’Connell, Ralf Eichhorn, Georg.

Similar presentations


Presentation on theme: "Cryomodule prototype Yun He, Dan Sabol, Joe Conway On behalf of Matthias Liepe, Eric Smith, James Sears, Peter Quigley, Tim O’Connell, Ralf Eichhorn, Georg."— Presentation transcript:

1 Cryomodule prototype Yun He, Dan Sabol, Joe Conway On behalf of Matthias Liepe, Eric Smith, James Sears, Peter Quigley, Tim O’Connell, Ralf Eichhorn, Georg Hoffstaetter

2 Prototype cryomodule 2 Differences of Prototype Module from Linac Module Flange-to-flange: 10.4 m Prototype moduleLinac module Cryogenic feedingFront cryo-feed can Side cryo-feed module Cryogenic pipingWith flange/elbow pre-welded Straight Welded in-situ End capYesIntermodule Connection between HGRP & 2k-2 phaseMiddle & endMiddle SC magnets/BPMsNoYes Beamline warm-cold transitionYesOn end modules Wire position monitorYesNo Cryo-feed canEnd cap Yun HE, MLC External Review10/3/2012

3 3 Cryo-feed can Cryo feed head from heat exchanger, to feed cryogen to module Yun HE, MLC External Review10/3/2012 HGRP and six lines – 1.8K -- 5K (supply, return) -- 40-80K (delivery, supply, return) Two lines to be blanked off Shield end section mounted to main shield End plates in two halves

4 10/3/2012Yun HE, MLC External Review4 Cooling pipes Flanges/elbows to connect to cryo-feed head are pre-welded

5 5 End cap Piping blanked off HGRP 5K (supply & return) 1.8 K 40 K return 40K delivery & supply lines connected by ½” tubing Yun HE, MLC External Review10/3/2012 Port for access to tuner/GV Manual gate valve to be supported with G10 to HGRP, w/ key alignment 40K shield curved inwards Manual gate valve intercepted @80K

6 6  For prototype, a second connection between HGRP and 2K-2 phase at far end provides cooling of the second half section of HGRP  A bellows section at very end on 2K-2 phase  This applies to the last cryomodule in the linac string Cooling of 2 nd half of HGRP for prototype module Yun HE, MLC External Review10/3/2012 Pipe support

7 Bellows section connects beampipe to end flange of can allows for displacements of beamline at cold Vertical: 1.2 mm Longitudinal: 8 mm 7 Beamline warm-cold transitions Gate valves intercepted @80K Replacement of SC magnets Yun HE, MLC External Review10/3/2012  Warm-cold transitions, wall 1.65mm  Will have sliding joints on beamline outside module to accommodate beamline shifts at cold

8 Heat treated CuBe wire ( ɸ 0.5 mm) is stretched parallel to the beam axis providing a position reference  For prototype module only, to monitor relative displacement between the wire and cold mass Mounted on end cap flanges (room temperature), thus the wire position is not influenced by cool-down A WPM sensor consists of four striplines spaced 90° apart 8 Wire position monitor Sensors attached to end flange of cavity LHe vessel Two sensors for 1 st, 3 rd, 5 th cavities to monitor pitch displacements One sensor for each of the rest three cavities Yun HE, MLC External Review10/3/2012