TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 42 of 50 Fission Products NOBLE GASES Kr-85m Kr-87.

Similar presentations


Presentation on theme: "TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 42 of 50 Fission Products NOBLE GASES Kr-85m Kr-87."— Presentation transcript:

1 TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 42 of 50 Fission Products NOBLE GASES Kr-85m Kr-87 Kr- 88 Xe-133 Xe-135 Xe-138 RADIOIODINES I-131 I-132 I-133 I-134 I-135 FISSION PRODUCTS Zr-95 Nb-95 Mo-99 Ce-141 Ce-144 La-140 Ru-103 Ru-106 Rb-88 Sr-89 Sr-90 Sr-91 Sr-92 Cs-134 Cs-137 Cs-138 Ba-139 Ba-140 Ba-141 Tc-99m H-3 from ternary fission

2 TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 43 of 50 Activation Products ACTIVATION PRODUCTS H-3 N-13 N-16 F-18 O-19 Na-24 Cl-38 P-32 ACTIVATED CORROSION PRODUCTS Cr-51 Mn-54 Mn-56 Fe-59 Co-58 Co-60 Cu-64 Zn-65 Zr-95

3 TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 44 of 50 DAC, DACF, %DAC and DAC-hours Derived Air Concentration (DAC) – concentration of a given radionuclide in air, which if breathed by the reference man for a working year of 2000 hours under conditions of light work, results in an intake of one ALI, annual limit on intake. DAC Fraction (DACF) – the fraction of the DAC value that is present. It is calculated by dividing air activity by the limit. %DAC – the percentage of the DAC value that is present. DAC-hour – indicates the amount of exposure. It is calculated by multiplying the DACF or the %DAC by the time in the area.

4 TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 45 of 50 Calculating DACF, %DAC, DAC-hours, and Exposure DACF ACTUAL LIMIT %DAC ACTUAL X 100 LIMIT DAC-hours DACF X hours Exposure DAC-hours X 2.5 mrem/hr

5 TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 46 of 50 Requirements For Respirator Issue Medical Clearance – S-3 (S-4 for SCBA) General Employee Training - RRT010 (HPT0063.002 for SCBA) Mask Fit Test – Not required for Tyvek hood or bubble hood Clean Shaven on Sealing Surfaces – Not required for hoods Corrective Eyewear – if required (Special frames for face masks) RWP or Industrial Safety Form

6 TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 47 of 50 Protection Factors Respirator TypeParticulate P.F.Iodine P.F. Twin Cartridge1001 PAPR without blower1001 PAPR hood or mask 1000 *1 Supplied Air hood or mask 1000 SCBA10,000 * Sequoyah uses a protection factor of 100 for PAPR.

7 TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 48 of 50 Procedures TVAN Standard for Respiratory Protection is SPP-5.10 Browns Ferry uses RCI-3.1 Sequoyah uses RCI-4 Watts Bar uses RCI-107

8 TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 49 of 50 Requirements of SPP-5.10 Certified by NIOSH/MSA RWP to document entry and specify type of respirator or IS Valid worker qualifications Issued from designated location and only to wearer Test and inspect filters and canisters after each use Clean, sanitize, survey, and inspect respirators after each use Periodic whole body counts to evaluate program

9 TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 50 of 50 When is Intake Monitoring Required?  Adults likely to receive an in excess of 10% of ALI in one year  Minors likely to receive a committed dose equivalent of 0.100 Rem in one year  Declared pregnant women likely to receive, during the entire pregnancy, a committed effective dose equivalent in excess of 0.100 Rem


Download ppt "TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.023 Revision 3 Page 42 of 50 Fission Products NOBLE GASES Kr-85m Kr-87."

Similar presentations