Parameter to be measured Proposed Diagnostic System Critical Components Relevant Radiation fields Potential radiation effects Li temperatureIR camera Lens20-50.

Similar presentations


Presentation on theme: "Parameter to be measured Proposed Diagnostic System Critical Components Relevant Radiation fields Potential radiation effects Li temperatureIR camera Lens20-50."— Presentation transcript:

1 Parameter to be measured Proposed Diagnostic System Critical Components Relevant Radiation fields Potential radiation effects Li temperatureIR camera Lens20-50 Gy/sChanges in refraction index Optical Fibres5x10 -4 -5 Gy/sRadioluminescence Mirrors4x10 8 n/cm 2 /s + LiSurface Degradation Wave pattern Electrical conductivity contact probe Contact Metallic ProbesHigh neutron fluxSwelling InsulatorsLi bombardmentSurface short circuit due to Li Stepping motor High Gamma & Neutrons rad. fields Degradation of coils insulation and Swelling in the central gear Stereoscopic Optical System CCD-Cameras & Windows7-8 Gy/s Radioluminescence & Optical Absorption Back-plate & Nozzle status Interferometer Technique Optical Windows10 8 -10 9 n/cm 2 /s Radioluminescence & Optical Absorption Probe head of the Thickness Monitor. Contact probe for Thickness Monitor Amplitude of the surface waves should be less than 1 mm. Based on electrical conductivity, the monitor has four pins to measure the amplitude of surface waves on the Li flow. Accuracy of this system should be 0.01 mm Back plate surface roughness monitor The distortion of back plate must be monitored during Li dumps to check the required replacement. The Interferometer technique is proposed for this monitoring. Critical elements will be optical components as the window and the mirror. Plane view of the IFMIF building showing the locations of FM laser radar Measurement of the deuterium footprint and Li free surface temperature is necessary for the safe operation of IFMIF. An infrared camera system is the reference diagnostic for this measurement. Concerning elements are the optical components as fibers, lens and mirror. Diagnostic system for target temperature Radiation Effects in IFMIF Lithium Target Diagnostic Systems J.Molla*, R.Vila, A.Ibarra: Laboratorio Nacional de Fusión, CIEMAT, Madrid, Spain (*) at present: IFMIF-EVEDA Project Team, Rokkasho-mura, Japan M.Ciotti: ENEA CR Frascati, Roma, Italy S.Simakov: Forschungszentrum Karlsruhe, Instituts für Reaktorsicherheit, Karlsruhe, Germany T. Shikama: Tohoku University, Oarai, Japan H.Horiike: Osaka University, Osaka, Japan Introduction : The liquid lithium target will be the intersection of the three main systems of IFMIF. An average heat load of 1 GW/m 2 will be deposited in the target (20x5 cm 2, 5 mm thick). Parameters as lithium temperature (250 C), wave pattern or lithium velocity (15 m/s) must be measured not only for the adequate operation but also for safety. Calculation of radiation fields Lithium Nozzle Deuteron Beams Test Modules Footprint 200 x 50 mm Target & Back-Wall Some of the required diagnostic system will be exposed to intense radiation fields (up to 100 Gy/s) and also to lithium ions bombardment. Radiation effects may make the diagnostic to fail. Critical elements will be The metallic probe due to the swelling MgO insulators: it may be short circuited due to the Li ions bombardment. Stepping motor: its electrical coils insulators (usually organic materials) will be exposed to intense radiation fields) Stepping motor: there is a risk of malfunctioning due to the swelling in its central gear that will be exposed to high neutronic fields. This work describes the potential radiation effects in the critical components of the proposed diagnostic systems. The Montecarlo code McDelicious was used to calculate the radiation fields in the target volume. This code is able to simulate the generation of neutrons, gamma rays and other d-Li reaction products. The three dimensional model used in the calculations includes the latest modifications of IFMIF design and Test Cell geometry. Silica material was chosen for the calculation because most of the diagnostics are based in optical measurements.


Download ppt "Parameter to be measured Proposed Diagnostic System Critical Components Relevant Radiation fields Potential radiation effects Li temperatureIR camera Lens20-50."

Similar presentations


Ads by Google