Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 Forces Yury Ivanyushenkov RAL. 2 Goal: find maximal (static and dynamical) possible forces in MICE magnetic system. Method: calculation of axial magnetic.

Similar presentations


Presentation on theme: "1 Forces Yury Ivanyushenkov RAL. 2 Goal: find maximal (static and dynamical) possible forces in MICE magnetic system. Method: calculation of axial magnetic."— Presentation transcript:

1 1 Forces Yury Ivanyushenkov RAL

2 2 Goal: find maximal (static and dynamical) possible forces in MICE magnetic system. Method: calculation of axial magnetic forces in MICE by using OPERA package (and other codes). Cases to be analyzed: - MICE stages III, IV, V and VI (see next slide): Parameters (proposal): magnetic modes - flip, semi-flip and non-flip; momentum (MeV/c) – 140, 170, 200, 240; beta (cm) – 7, 15, 25, 42; coil currents - 0 (coil is off or quenched), nominal, max (critical current ?); magnetic shielding – with and without. - Abnormal cases: - dynamical forces during quenches; - anything else? Aims of work

3 3  - STEP I: spring 2006 STEP II: summer 2006 STEP III: winter 2007 STEP IV: spring 2007 STEP V: fall 2007 STEP VI: 2008 MICE Stages by Alain Blondel

4 4  - STEP I STEP II STEP II.V Insert absorber (solid) between the two halves and measure Pt & E distribution and emittance growth STEP II.VI Split tracker in two parts and measure against each other (systematics) Establish beam match andwether we have all knobsnecessary to drawEmittance vs transmissioncurve. Measure emittance These are mostly questions for beam design and matching to and within solenoid. MICE Additional Stages by Alain

5 5 STEP V STEP V.0 Shorter, less expensive, no coupling coil, (very limited optics flexibility) does this work in flip, RFoFo, non flip modes? These are mostly optics questions MICE Additional Stages by Alain

6 6 Beam Coupling Focus #3 Match #1 Centre Match #2 End #2 Coil Terminology End #1 Focus #2 Focus #1

7 7 Model in OPERA Model: -18 coils; - no magnetic materials

8 8 Coil Geometry for Stage 6 From MICE TRD

9 9 Coil Currents for Flip Mode Cases in Stage 6 From MICE TRD

10 10 Coil Currents for Non-Flip Mode Cases in Stage 6 From MICE TRD

11 11 Forces on Coils for Flip Mode Cases in Stage 6

12 12 Forces on Coils for Non-Flip Mode Cases in Stage 6

13 13 Forces on Modules for Flip Mode Cases in Stage 6 Case 1Case 2Case 3Case 4Case 5 Average p (MeV/c)200240200170140 Absorber beta (cm)42 25157 Force on the module (MN): Central focus pair module00000 Coupling coil module0.1422 from centre 0.2143 from centre 0.1140 from centre 0.0536 from centre 0.0070 from centre Edge focus pair module0.0693 from centre 0.0877 from centre 0.0967 from centre 0.0846 from centre 0.0631 from centre Tracker solenoid module-0.2372 towards centre -0.3343 towards centre -0.3000 towards centre -0.2284 towards centre -0.1308 towards centre

14 14 Forces on Modules for Non-Flip Mode Cases in Stage 6 Case 1Case 2Case 3Case 4Case 5 Average p (MeV/c)200240200170140 Absorber beta (cm)42 25157 Force on the module (MN): Central focus pair module00000 Coupling coil module0.1239 towards centre 0.1859 towards centre 0.1005 towards centre 0.0756 towards centre 0.0278 towards centre Edge focus pair module0.0123 towards centre 0.0372 towards centre 0.0101 from centre 0.0195 from centre 0.0814 from centre Tracker solenoid module0.3588 towards centre 0.4861 towards centre 0.4321 towards centre 0.4526 towards centre 0.3998 towards centre

15 15 Maximal Forces on Modules in Stage 6 ModuleMax force, MN Case Central focus pair module0All Coupling coil module0.2143 from centre; 0.1859 towards centre Flip mode, Case 2 Non-Flip mode, Case 2 Edge focus pair module0.0967 from centre; 0.0372 towards centre Flip mode, case 3 Non-Flip mode, Case 2 Tracker solenoid module0.4861 towards centre Non-Flip mode, Case 2

16 16 Quenches in Stage 6, Flip mode, Case 2 Module quenched Force on module, MNFocus pairCoupling coilTracker solenoid Central focus pair module 0.0 Coupling coil module0.2110 from centre 0.0 0.3126 from centre Edge focus pair module 0.0 0.3975 from centre 0.3120 towards centre Tracker solenoid module 0.0644 from centre 0.4187 towards centre 0.0 Note that forces are sometime higher than in the normal mode !

17 17 Forces in Stage 3 Coil geometry and currents are taken from the talk OPTICS OF STAGE III by Ulisse Bravar at MICE Video conference on October the 6 th.

18 18 Forces on Tracker Modules for Flip Mode Cases in Stage 3 Case 1Case 2Case 3Case 4 Average p (MeV/c)240200170140 Force on module, MN Tracker solenoid module0.1446 from centre 0.1169 from centre 0.0845 from centre 0.0573 from centre

19 19 Forces on Tracker Modules for Non-Flip Mode Cases in Stage 3 Case 1Case 2Case 3Case 4 Average p (MeV/c)240200170140 Force on module (MN) Tracker solenoid module0.1958 towards centre 0.1173 towards centre 0.0847 towards centre 0.0575 towards centre

20 20 Conclusions Conclusions: it seems there is no a single worst case for all the modules

21 21 Proposal for the next steps: make similar analysis for Stage 3 and other stages (when geometry and currents are defined ); include abnormal cases into analysis; identify the worst case for each module; check worst cases with OPERA including shielding in the model; anything else ? Next steps