Presentation is loading. Please wait.

Presentation is loading. Please wait.

Schmitz F., Van Naemen J., Monclus M., Van Gansbeke B., Kadiata M., Ekelmans D., Moray M., Penninckx R., Goldman S. PET/Biomedical Cyclotron Unit, ULB-Hospital.

Similar presentations


Presentation on theme: "Schmitz F., Van Naemen J., Monclus M., Van Gansbeke B., Kadiata M., Ekelmans D., Moray M., Penninckx R., Goldman S. PET/Biomedical Cyclotron Unit, ULB-Hospital."— Presentation transcript:

1 Schmitz F., Van Naemen J., Monclus M., Van Gansbeke B., Kadiata M., Ekelmans D., Moray M., Penninckx R., Goldman S. PET/Biomedical Cyclotron Unit, ULB-Hospital Erasme, Route de Lennik, 808, B-1070, Brussels, Belgium During these last ten years, the radiopharmaceuticals producers’ community has experienced tremendous changes. Historically, this occurred mainly because of hardware improvements : cyclotron, targets, radiochemistry involvement of the regulatory affairs and large extension of medical use of new radioisotopes or new radioisotopes production techniques. Companies specialized in the development and installation of accelerator-based systems dedicated to the medical applications brought on the market cyclotrons well fitted to the requests of the industrial community or universities and so covering every segment of the market. These machines are fully automatic, and need reduced maintenance; they are highly specialized for defined tasks. They can produce high beam intensity and realize dual beam irradiation. Also the prices are reducing considerably. The targets and the automatic system follow the same trend. Unfortunately, the flexibility of these devices for new area of research and development has been dramatically reduced. The growing number of PET cameras has increased the popularity of PET tracers used for nuclear imaging. Consequently, there is a growing demand for these radiopharmaceuticals compounds labeled with short-lived radioisotopes for clinical applications. From a research and development tool in the eighties, PET has now grown up to a clinical tool. Moreover, depending of the social welfare, reimbursement of some PET examinations is granted, which accelerates the trend for an extended use of PET tracers. Regulatory affairs try to establish and standardize the control on these radiopharmaceutical compounds produced in a growing number of local radiopharmacies owning a baby cyclotron. On the other hand, the attention of equipment suppliers was brought in the setting up of a total quality control follow up. These efforts were successively achieved by getting for instance the ISO 9001 certificate. The third factor of major changes in the cyclotron technology relates to attempts of transferring to cyclotron facilities the production of radioisotopes previously generated in nuclear reactors. This is the case, for instance for palladium-103 used in brachytherapy. Improvement of cyclotrons, successful development of local radiopharmacy dedicated to PET tracer production have contributed to an increase of production facility owning a cyclotron and radioisotopes produced by these accelerators. Production of radioisotopes by cyclotrons References 1.IAEA,Tecdoc-1211, Charged particle cross-section database for medical radioisotope production : diagnostic radioisotopes and monitor reactions 2.IAEA, Tecdoc-1007, Directory of cyclotrons used for radionuclide production in member states 3.IAEA-DCRP/CD, Directory of cyclotrons used for radionuclide production in member states Bean energy (MeV)ParticlesTypical beam intensity on beam stop (µA) Typical production 3D+D+ 80 15 O 10-13H - (5 MeV D - in option)100 15 O, 11 C, 13 N, 18 F 16-20H - (8-10 MeV D - in option)150 15 O, 11 C, 13 N, 18 F, 124 I, 86 Y 14-19H + or H - 2000 103 Pd 15-30H - (D- in option)1000 123 I, 201 Tl, 67 Ga, 111 In Table 1 : General basic characteristics of cyclotrons available on the market TargetBeam current (µA)Beam energy (MeV)Typical radioisotopes production Gas30-10010-30 11 C, 123 I, 15 O, 81 Kr, … Liquid10-7010-20 18 F, 13 N, … Solid Powder10-20 86 Y, 124 I, … Solid Electroplated800-1200 150-300 14 30 103 Pd 201 Tl, 67 Ga, 111 In, … Table 2 : Target performances


Download ppt "Schmitz F., Van Naemen J., Monclus M., Van Gansbeke B., Kadiata M., Ekelmans D., Moray M., Penninckx R., Goldman S. PET/Biomedical Cyclotron Unit, ULB-Hospital."

Similar presentations


Ads by Google