1 AJ5812 ENTERAL FEEDING PUMP

2 About Us Angel Canada Enterprises Ltd is a leading designer and manufacturer of a wide range of quality medical infusion and syringe pumps. Sales office in Canada Factory in Shanghai, China Sites are certified by TUV Rheinland with CE marking , ISO 9001 and ISO 13485 Company Headquarter in Vancouver, Canada

3 ANGEL’s Factory Over 19 years experience, first in China
specializing in medical pumps Located in Shanghai, China 40 employees and management still growing Two assembly lines One Class 100,000 Clean Room ISO 9001, ISO and CE RoHs certified

4 Quality Certificates

5 AJ5812 Enteral Feeding Pump
Total weight: 590 g (Internal battery included) A lightweight and compact enteral pump that helps both pediatric and adult tube-fed patients to maintain a normal lifestyle.

6 New Standards Environmentally Friendly: ROHS Complaint.
Comply with IEC rd Edition, which is in effect since July, 2014. Brand-new Purple Labelling: Complies with EU Standard for Enteral Nutrition Safety.

7 Ideal solution for HOME CARE HOSPITAL USE

8 MAIN FEATURES

9 Simple and Intuitive Design
Digital programming with easy-to-use keypad and user-friendly interface. Simply use Arrow Key to change data setting Cycle Key provides direct access to Cycle mode. Enter/Set Key to confirm each setting

10 Two Feeding Modes meet varies delivery requirements.
Continuous feeding Intermittent feeding

11 Continuous Feeding ML/H Mode Set rate in ml/h & volume limit.
Delivery completes when volume delivered reaches the present volume limit. Time Mode Set delivery time & volume limit. Auto calculation of flow rate. Screen displays volume limit and time remain. Delivery completes when time remain reaches 0.

12 Intermittent Feeding Delivery can be defined into 10 time periods (from 0 to 9). Set TIME and VOLUME for each period e.g. to pause the pump for 45 mins. between two delivery periods TIME: 45 min. VOLUME: 0 ml Delivery ends when the last period is completed.

13 CYCLE Function How to activate the CYCLE function:
Simply click CYCLE Key on the control panel. Once the pump completes intermittent periods, it will restart delivery from first period. CYCLE Function Repeat preset delivery periods. This function is only activated under Intermittent Delivery Mode.

14 On-screen critical data and full alarm messages
Large and Clear Display On-screen critical data and full alarm messages OLED large screen for clear view from distance in the night time

15 Preset Memories for Fast Setup
10 memory settings Preset delivery RATE & VOLUME. Speed setup by SELECT PRESETS *(SELECT PRESETS only available under ML/H mode).

16 Event Log on-screen event log with date & time stamp.
Over 1000 records of delivery history. Clearly shows delivery data including feeding status and alarm message.

17 Alarms Adjustable alarm sound : High / Medium / Low.
Full alarm message displayed on screen. Delivery stops immediately once alarm condition occurs. Momentary alarm silence function. Delivery can only be resumed once alarm condition is cleared.

18 Versatile Working Environment
On IV pole Desktop In a backpack

19 Detachable Pole Clamp Fits All IV Pole

20 Easy to Transport Up to 24 hours built-in battery power
Easily carrying around with regular backpack Help patients main a normal and respectful lifestyle

21 Operation Guide Preparation before delivery
Attach feeding pump to IV pole and have the pump set ready. Open pump set package and take set out from pouch. Close roller clamp completely. Fill bag with desired volume of nutrient. Close bag by securing cap. Hang bag above and to side of the pump. Load pump set properly onto the feeding pump according to the following 4 steps.

22 Proper loading of the feeding set in 4 easy steps.
Insert the drip chamber firmly into the pocket on the front of the pump. Make sure it is properly seated.

23 Step 2: Gently wrap tubing around pump wheel, following the direction shows on the rotation label

24 Step 3: Slightly pull up the tubing and insert the white tube sensor to the sensor receptacle, and make sure it is firmly seated. Tube Sensor

25 Step 4: Wrap the tubing around the tube holder on the top of the sensor receptacle. Tube holder Follow these four steps and verify the feeding set is properly loaded before starting a delivery.

26 Start delivery Turn on power switch to activate feeding pump
Press ON/OFF key to turn on pump and enter into main menu. Press ENTER/SET to enter delivery setting menu. Press Arrow Key to set desired flow rate; press ENTER/SET key to confirm rate setting and enter into volume limit setting. Press Arrow Key to set desired volume limit; press ENTER/SET key to confirm setting and return to main menu. Open roller clamp on pump set, and remove tip protector from feeding adaptor. Press PURGE key to prime pump set and expel air and occlusions out of the tubing. Connect set to patient’s enteral feeding tube. Press START/STOP key to start delivery.

27 Consumables AJ5812 feeding pump is calibrated to ANGEL 1200 ml Enteral Feeding Pump Set. Anti-free-flow design DEHP and Latex free Built-in hanger Top-fill opening with leak proof cap to minimize spills and waste. For enteral use only, not for IV use Sterile Content: bag and tubing

28 SPECIFICATIONS Flow rate 1 – 600 ml/h Feeding mode Continuous and intermittent feeding Mechanism Continuous rotary peristaltic Accuracy ±10% Disposable pump set Proprietary 1000ml enteral pump set Flow pressure 15 psi Operation power DC power: 10VDC:1.5 A Battery Built-in rechargeable lithium battery. 24-hour after charging for 6 hours. Occlusion pressure 5.8 – 23.2 psi Dimension 165(W) mm × 60 (D) mm ×130 (H) mm Weight 590 g/ 1.3 lbs. (battery included)

29 Contact Us We appreciate your trust in us! Angel Canada
# Underhill Ave. Burnaby, BC Canada V5A3C2 Tel: Fax: Angel China 4/F Building 5, No. 1135, Baotou Road, Shanghai, China Tel: Fax: Website: