Presentation is loading. Please wait.

Presentation is loading. Please wait.

E.C. Aschenauer RSC-Meeting, January 21st 2011 1 T h e b e s t k e p t s e c r e t n u m b e r a t R H I C / B N L / U S A f o r s u r e n o t t o b e.

Similar presentations


Presentation on theme: "E.C. Aschenauer RSC-Meeting, January 21st 2011 1 T h e b e s t k e p t s e c r e t n u m b e r a t R H I C / B N L / U S A f o r s u r e n o t t o b e."— Presentation transcript:

1 E.C. Aschenauer RSC-Meeting, January 21st 2011 1 T h e b e s t k e p t s e c r e t n u m b e r a t R H I C / B N L / U S A f o r s u r e n o t t o b e f o u n d o n w i k i l e a k s

2 RHIC pC Setup Run11 E.C. Aschenauer RSC-Meeting, January 21st 2011 2

3 Polarimeter Status  Work during access on Wednesday:  fixed problem with readout of yellow-1-downstream polarimeter  investigated problem with current monitoring of Y2U  spares of modules involved located  can hopefully fix the problem at the next access day E.C. Aschenauer RSC-Meeting, January 21st 2011 3 Hardware status okay  Change in operational procedure:  turn off Si bias voltage during beam studies, tune-up, APEX  keep radiation damage at a minimum 111 bunch injection studies

4 First Data from B1 & B2 Polarimeters E.C. Aschenauer RSC-Meeting, January 21st 2011 4 Blue-1 Upstream Blue-2 Downstream Raw Data: bananas clearly visible calibration ADC -> energy alpha calibrations need to correct for Si – dead layer

5  -Calibration E.C. Aschenauer RSC-Meeting, January 21st 2011 5 Blue-1 Upstream Blue-2 Downstream factor 2 in position comes from the fact that downstream polarimeters don’t use shapers, which also amplify Remember  ’s penetrate factor 10 deeper into Si than carbons Plan for upcoming shutdown: install 2 nd source Gd with different  - energy install different foils to attenuate  – energy (tests in lab planned)

6 Blue-1 Upstream Blue-2 Downstream Blue-1 Upstream Blue-2 Downstream RSC-Meeting, January 21st 2011 6 Data after Corrections E.C. Aschenauer t0t0 Energy-Scale Current Puzzle: difference between t0 and energy scale correction factor energy-scale correction based on Si dead layer

7 Data after all Corrections E.C. Aschenauer RSC-Meeting, January 21st 2011 7 Blue-1 Upstream Blue-2 Downstream After all corrections both polarimeters look very similar A r e y o u r e a d y ? ? ? ? F a s t e n y o u r s e a t b e l t s t h e s e c r e t w i l l b e r e v e a l e d

8 Polarization at Injection for Blue Ring E.C. Aschenauer RSC-Meeting, January 21st 2011 8 14807.003: blue1 upstream P = 51 +/- 3 % (stat only) 14807.212: blue2 downstream P = 49 +/- 3 % (stat only)

9 To Do  Update parameters in online polarization calculation to get reasonable numbers  Investigate the difference in energy-scale constant between B1 and B2  see we get the same result for Y1 and Y2 (just collected the data last night)  measure linearity of energy response of different systems  vary pulser amplitude  latest during the next access day  Need good data for Y1 and Y2 polarimeters to determine parameters for online, most likely the ones from last night will do.  Analyze the polarization at flat top for B2  Next access-day  fix bias voltage readout  bring hopefully one detector back to live in Y2U by changing pre-amp box E.C. Aschenauer RSC-Meeting, January 21st 2011 9


Download ppt "E.C. Aschenauer RSC-Meeting, January 21st 2011 1 T h e b e s t k e p t s e c r e t n u m b e r a t R H I C / B N L / U S A f o r s u r e n o t t o b e."

Similar presentations


Ads by Google