Presentation is loading. Please wait.

Presentation is loading. Please wait.

OBC 2009 CHAPTER FIVE GENERAL BUILDING HEIGHTS AND AREAS.

Similar presentations


Presentation on theme: "OBC 2009 CHAPTER FIVE GENERAL BUILDING HEIGHTS AND AREAS."— Presentation transcript:

1 OBC 2009 CHAPTER FIVE GENERAL BUILDING HEIGHTS AND AREAS

2 OVERVIEW  REGULATES THE MINIMUM TYPE OF CONSTRUCTION  AREA MODIFICATIONS  HEIGHT MODIFICATIONS  MEZZANINES REQUIREMENTS  UNLIMITED AREAA STRUCTURES.  PARKING GARAGES RELATED ISSUES.

3 OBJECTIVES  USE TABLE 503  ADDITIONAL PROTECTION FEATURES TO MODIFY HEIGHTS AND AREAS.

4 ALLOWABLE AREA  ESSENTIALS TO DETERMINE THE ALLOWABLE AREAS: –TYPE AND AMOUNT OF COMBUSTIBLES DUE TO USE OF BUILDING –AMOUNT OF COMBUSTIBLES CONTAINED IN THE CONSTRUCTION OF A BUILDING –SPRINKLER, OPEN YARD, FIRE WALL

5 AREA LIMITATIONS  DETERMINE THE TABULAR AREA  MODIFY THE TABULAR AREA  MAXIMUM BUILDING AREA IS INTENDED TO LIMIT THE SIZE OF THE FIRE AND TO CONTROL THE SPREAD OF FIRE, LIFE SAFEY, ACCESS TO FIRE DEPARTMENT PERSONNEL.  MEZZANINE DOES NOT CONTRIBUTE TO BUILDING AREA  MAXIMUM ALLOWABLE AREA IS LIMITED TO ALLOWABLE AREA PER FLOOR MULTIPLIED BY THREE.

6 HOW DO WE DETERMINE THE CONSTRUCTION TYPE  1. IDENTIFY THE USE  2. IDENTIFY AREA AND HEIGHT  3. DETERMINE THE CONSTRUCTION TYPE  NOTE: IF THE USE AND CONSTRUCTION TYPE ARE DEFINED BY THE DESIGN PROFESSIONAL THEN THE AREA AND HEIGHT LIMITATIONS WILL BE ESTABLISHED FROM TABLE 503

7 TABLE 503  ALLOWABLE HEIGHT AND AREA  USE GROUP  CONSTRUCTION TYPE  NUMBER OF FLOORS  AREAS PER FLOOR  HEIGHT: # OF STORIES AND FEET ABOVE GRADE PLANE

8 EXAMPLES  M USE, IIB  AREA:  HEGHT:  # OF STORIES:

9 HEIGHTS MODIFICATIONS  504 –SPRINKLER SYSTEM NFPA 13 A MAXIMUM OF ONE STORY A MAXIMUM ADDITIONAL HEIGHT OF 20 FEET. R USES IS LIMITED TO FOUR STORIES AND 60 FEET IF NFPA 13R IS USED

10 EXAMPLE  B USE, IIB, NFPA 13 –4 STORY –75 FEET –AREA INCREASE

11 AREA INCREASE  506 –A a = A t + { A t I f /100} + { A t I s /100} –Frontage and sprinkler increase –I f = 100[F/P –0.25]W/30 W Minimum 20 feet Weighted average If W > 30 USE 30 –W=60 IF ALL REQUIREMENTS OF 507 ARE MET EXCEPT 60 FOOT

12 AUTOMATIC SPRINKLER SYSTEM  200 % FOR MULTISTORY STRUCTURES  300 % FOR SINGLE STORY BUILDINGS.  SEE THREE EXCEPTIONS OF SECTION 506.3

13 MIXED USES 508 OBC  INCIDENTAL USE AREAS –SEPARATED OR PROTECTED PER TABLE 508.2  MIXED OCCUPANCIES 508.3 –ACCESSORY USE AREAS –NONSEPARATED –SEPARATED USES –TABLE 508.3.3  2007 CHANGES  502.1, 202 DEFINITIONS OF BASEMENT AND STORY ABOVE GRADE PLANE.  TABLE 503 MODIFIED FOR H-5 USE.  503.1.1 UNLIMITED HEIGHT AND AREA FOR SPECIAL INDUSTRIAL OCCUPANCY F- 1 AND F-2 ONLY  MODIFICATION OF SECTION 504.2 HEIGHT INCREASE TO THE ENTIRE FIRE AREA

14 2007 CHANGES  AN ADDITION TO SECTION 505.2 FLOOR AREA OF MEZZANINE LIMITED TO 50% OF ROOM IN WHICH IT IS LOCATED TYPE I OR II, FYLLY SPRINKLERED, AND EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM

15 2007 CHANGES  AN ADDITION TO SECTION 505.4 NEW EXCEPTION ALLOWES FOR TOTAL ENCLOSURE OF A MEZZANINE IF THERE ARE AT LEAST TWO MEANS OF EGRESS.  CLARIFICATIONS FOR ALLOWABLE AREA CALCULATIONS, 506.1, 506.2, 506.3

16 2007 CHANGES  CLARIFICATIONS TO SECTION 506.2.1 FOR I f CALCULATIONS  MODIFICATION TO SECTION 506.4.1 ALLOWABLE AREA OF MIXED OCCUPANCY BUILDINGS. VERTICAL AND HORIZANTAL RATIOS.

17 2007 CHANGES  ADDITIONAL LANGUAGE TO SECTION 507.3 GROUP A OCCUPANCY LOCATED IN UNLIMITED AREA BUILDINGS.. FOUR CONDITIONS.  ADDITIONAL LANGUAGE TO REDUCE OPEN SPACE FOR UNLIMITED AREA BUILDINGS

18 2007 CHANGES  MODIFICATIONS TO SECTION 507.7 THAT DEAL WITH GROUP H OCCUPANCIES IN UNLIMITED AREA BUILDINGS.  CLARIFICATIONS TO SECTION 508.2 INCIDENTAL USE AREAS  CLARIFICATIONS TO SECTION 508.3 MIXED OCCUPANCIES SEVERAL SUBSECTIONS MODIFIED/CLARIFIED  TABLE 508.3.3 MODIFIED TO MAKE IT EASY TO USE

19 2007 CHANGES  509.2 MODIFIED  509.8 A NEW SECTION TO DEAL WITH GROUP B OR M THAT OCCUR BELOW AN OPEN PARKING STRUCUTRE

20 2009 CHANGES  501.2  502.1  503  504  505  506  507  508  509