Presentation is loading. Please wait.

Presentation is loading. Please wait.

Energy Management System Future Group. How Energy Management System helps  Gives Electrical parameters and energy consumption Section or store wise for.

Similar presentations


Presentation on theme: "Energy Management System Future Group. How Energy Management System helps  Gives Electrical parameters and energy consumption Section or store wise for."— Presentation transcript:

1 Energy Management System Future Group

2 How Energy Management System helps  Gives Electrical parameters and energy consumption Section or store wise for taking corrective actions  Gives a clear picture about energy costs involved per store.  Helps to optimize and Monitor Electrical Parameters to achieve Energy saving and Electrical Equipment Safety

3 Key Features - Analysis Reports Consumption reports Specific parameter report. Total consumption report. Billing reports. Sub Billing for tenants or different cost centers.

4 System Architecture PHOENIX MALL R MALL GROWEL MALL OBEROI MALL R-CITY MALL MEGA MALL EVERSHINE MALL INFINITY MALL SOBO CENTER HUB MALL ORCHID MALL K-STAR MALL MILLAN MALL All the sites are directly connected to the LAN network of the Future Group. We can see all the sites from any one of site by using desired Username and Password.

5 Accessing PowerMan from your PC 1. Go to Internet explorer & type http://10.0.119.11:8080/PowerMan 2. Login page of PowerMan will come 3. Use your User Name & Password to access the system

6 Login Page 1. PowerMan supports multiple user interface. 2. In order to access Power Man Application, it is necessary to pass through authentication.

7 How to Monitor Consumption 1. You can generate consumption graph for individual meter. 2. Select LOCATION from location list. 3. Select METER for which you want to generate graph. 4. Select date from calendar. To change month or year click on ‘ ’ Signs. 5. Apart from Horizontal bar graph you can select vertical bar, pie chart, Vertical 3D bar, Horizontal 3D bar, Pie 3D, stacked vertical bar, stacked vertical bar.

8 After above process you will get this type of screen which shows per day consumption of each meter. You can view the consumption values even in tabular format by selecting Textual overview option.

9 Graphical representation of Consumption  Comparison The comparison between planned and actual consumption of power or between two modules or load profiles of two or more modules is possible.

10 How to Monitor Current, Voltage Similar to consumption graphics you can generate load profile graph for Instantaneous parameters like voltage, current, Frequency, Active Power, Average current and voltage, Phase angle etc.

11 How to monitor real time trend  Real Time Trend Real time trend charts of any of the parameters can be viewed separately or together on a single screen for a particular meter.  Parameters Monitored All the various parameters like Voltage, Current, Active Power, Frequency, voltage, current, etc can be monitored and graphically represented.

12 How to download reports in Excel With screen you can generate Total Consumption report. Properties of Total Consumption screen. Company: It is requires to select Company from list. Location: It is requires to select Location from list. Channel: It is requires to select Channel from list. Relative Date: It is requires to select Relative Date by selecting appropriate option. Start Date: It is requires to select Start Date from which you want to generate report. End Date: It is requires to select End Date till which you want to generate report. Report Name: This field is mandatory and Report Name is required to define. Excel Code Generator: To download the report into Excel click on Excel Code Generator

13 In case of missing readings:  To Check Energy Meter : 1. Check whether all parameters are showing properly in meter display like Current, Voltage, KW, etc. 3. If any Current or active power value gets improper value then have to check CT connections. How to check hardware components :

14  check Com Controller : 1. Check auxiliary power supply of controller, whether RED LED glows, Green LED blinks. 2. Then check whether Network cable (controller to switch) is properly connected 3. If above all conditions are satisfied then check whether com-controller is in network

15 CONNECTION DETAIL DATA CABLE CONNECTION 1.Server switch to com controller cat 5 straight cable 2.Controller to meter cat 5 as per connection detail 3. Meter to meter as per connection detail (CAT 5) POWER CABLE CONNECTION 1.Com controller 230 v supply 2.Meter – 3 phase ct connections R Y B N supply connections auxiliary supply connection

16 How to check networks

17 Contact Details Pramod Sapkal 9967530805 Anurag Giri 09820689255 Sajiv K.V. 09322259684 Dinesh Shingote 09664351059 San Lazaro 09324712300