1 US Navy Entomology Center of Excellence, Jacksonville, FL
CUTTING EDGE TECHNIQUES TO MEASURE DROPLET SPECTRUM AND CHEMICAL DEPOSITION OF PESTICIDE SPRAY Muhammad Farooq US Navy Entomology Center of Excellence, Jacksonville, FL

2 Disclaimer The views expressed in this presentation are those of the author and do not necessarily reflect the official policy or position of the Department of the Navy, Department of Defense, or the U. S. Government.

3 Spray Application

4

5 Intrusive Methods Coated Slides
Coated with MgO, teflon, gelatin, petroleum, resins Impressions or stains are measured Droplet size determined indirectly Mainly suitable for laboratory measurements due to handling issues

6 Intrusive Methods Coated Films Glossy Paper Leaf Surfaces Liquid Media
Water Sensitive paper Oil Sensitive paper Coated Films Glossy Paper Leaf Surfaces Liquid Media

7 Intrusive Methods Cascade Impactors Air sampled
Droplets segregated by inertial separation Amount on each stage related to droplet size Air speed increases and droplet size decreases Source:

8 Intrusive Methods Fibrous Media Droplets captured on fibers
Droplet size measured directly Research on ways to measure droplets on fibers lead to development of Army Insecticide Measurement System then DCIII Source: CAB International, 1993

9 DCIII Portable Droplet Counter

10 Enhancement of Analysis Techniques for Intrusive Methods
Reading slides Manually using microscope Drop Vision System that scans slide in to computer that measures the droplet sizes

11 Drop Vision Slide Microscope with digital image processor
Droplet Image Analysis software Graphing & Reporting software

12 Sensitive Paper Reading System
Cards Scanned as Bitmap Image analyzed with Stainalysis or with WRK Image Analyzer Droplet size Droplet density Percent coverage of card surface

13 Reading of Collected Droplets by Photography
Source: Aalborg University, Denmark, Website

14 Non-Intrusive Methods
Photographic Measurements Holographic Optical Array Spectrometer Light Scattering Laser Doppler droplet sizing

15 Photographic Measurements
Frozen image by Short duration high intensity light Mercury vapor lamp, electric spark and flash => 1 ms duration Laser pulses => order of ns High speed camera Images read by image analysis programs Two pulses => Droplet size and velocity

16 Frozen Image

17 Photomicrography Rathburn & Miserocchi, JEE, Feb. 1967

18 Laser Imaging Source:

19 Image Analysis for Size and Velocity
Source:

20 Frozen Image of fast moving object
Source:

21 Interferometric Mie Imaging
Fringe pattern produced by out of focus imaging Number of fringes related to droplet size Droplet size and 3-D Velocity Number density Mass Flux Size-Velocity correlation Source:

22 Shadography High Magnification Image for visualization
Sizing by image analysis Droplet size, shape and 2-D Velocity Number density, Mass Flux Size-Velocity correlation Source:

23 Particle Image Velocity
6-10 ns image 100 ns time between images Source:

24 Digital Image Correlation
Source:

25 Systems Developed Particle Master Spray Master Flow Master
Size and Velocity of droplets Spray Master Visualization of spray Flow Master Study of flows Strain master Deformation of flows or materials under stress

26 Holography The image can be reproduced with laser to measure droplets

27 Optical Array Spectrometers Principle
Number of obscured diodes related to droplet size Source: CAB International, 1993

28 Light Scattering Methods
Light Intensity Technique Forward scattering spectrometer probe (FSSP) Laser Diffraction Technique Malvern droplet sizing system Sympatec droplet sizing system

29 Light Intensity Technique
Source: CAB International, 1993

30 Laser Diffraction Technique Principle
Source: CAB International, 1993

31 Laser Diffraction Technique
Location of droplet in the beam does not effect the size determination Source:

32 Laser Diffraction Technique
Use He-Ne class 3, nm laser Spatial measurement systems Easy to set-up and align Provide volume distribution of droplet size Data Rate up to 10 kHz Size range Malvern: 0.1 to 2000 mm with two lenses Sympatec: 0.1 to 3500 mm with 8 lenses

33 Laser Doppler Droplet Sizing Principle
Beam splitter Measurement /probe volume Detector 1 Detector 2 Detector 3 Measurement volume

34

35 Laser Doppler Droplet Sizing Principle
Filtered signal Frequency of the signal related to droplet velocity Phase shift related to droplet size  Doppler Signal

36 General Features of PDPA
The PDPA is a flux sampling instrument (single particle counter) Provides simultaneous measurement of velocity and size of spherical particles Particle size between ca. 0.5 µm and several millimetres Can analyze many spray characteristics. The most important are: Droplet number distribution Droplet volume distribution Droplet velocity distribution Droplet concentration and Liquid Water Content Turbulence intensity Droplet size velocity correlation

37 Droplet Size-Velocity Correlation

38 Data Extraction Dia (mm) V (m/s) 0.01 5.46 0.17 8.13 0.44 5.51 0.03
10.17 0.18 7.95 0.46 9.03 0.05 4.26 0.22 8.28 3.68 7.72 0.25 6.79 7.10 0.07 7.97 0.29 6.40 0.47 6.69 0.08 5.44 0.33 1.95 0.48 7.51 0.09 8.46 8.03 0.50 7.42 0.10 6.51 0.35 4.18 3.66 0.12 7.00 0.37 6.94 1.87 8.42 0.38 3.55 1.93 0.13 11.85 0.39 4.19 0.52 8.65 3.60 1.47 0.54 6.18 0.14 5.24 0.41 0.55 2.57 0.16 6.02 0.43 9.41 0.56 3.67

39 Summary Data

40 Portable Particle Counters
Air contamination studies Air suction system Laser-based or centrifugal impaction Droplet size range: 0.3 – 20.0 µm Flow rate: Up to 100 L/min Solid particles in gases or liquids Looking for one to measure liquid droplets in air

41 PDI Flight probe Funded by US Navy for cloud and plane icing studies
Based on Laser Doppler sizing principle Design being optimized Source: Artium Technologies Inc.

42 Spray Application

43 Why Deposition? Fundamental part of sprayer evaluations in agriculture
Practices in public health Bio-assays Droplet size characteristics These techniques do not: Approve or disapprove the delivery system Elucidate the shortcomings of the equipment being tested Lead to improvements for meeting the objective

44 Deposition Measurement
Sampling Quantification may include extraction

45 Samplers Indicating Samplers Plant species for herbicides
Sensitive Paper Water sensitive Oil sensitive

46 Samplers Passive Samplers Cylindrical collectors Paper Mylar Sheet
Plant Leaves Cotton squares Filter papers Plastic tapes Cotton ribbons Useful for course high volume agricultural sprays

47 Samplers Active samplers Air Samplers
Rotating samplers Useful for sub-micron particles and ULV space sprays

48 Air Samplers Air drawn over a filter medium Flow rate known
Sampling time recorded Quantity of spray determined analytically. Result: Concentration of spray in air Concentration is a measure of flux

49 Air Sampler Settings Source: CAB International, 1993

50 Rotary Samplers Rotorod Sampler

51 Rotating slide samplers
Rotary Samplers Rotating slide samplers Source: John W. Hoch website

52 Rotary Samplers Rotating ribbon sampler FLB sampler
Source: AMCA Vol25 page 476

53 Quantification of Deposition
Water/Oil soluble tracer dyes mixed in tank Samples washed with suitable solvent Concentration of dye in wash solution quantified Dye on sample surface determined AI on sample surface determined using dye:AI ratio in the tank mixture

54 Collection by Samplers
AMCA Vol25 page

55 Sampler Collection Efficiency

56 Questions? DOD Pest Management Equipment Help Desk