Presentation is loading. Please wait.

Presentation is loading. Please wait.

Strain-Based Resistance of Single-Walled Carbon Nanotubes Abstract The goal of this project is to fabricate devices to test the strain-based change in.

Similar presentations


Presentation on theme: "Strain-Based Resistance of Single-Walled Carbon Nanotubes Abstract The goal of this project is to fabricate devices to test the strain-based change in."— Presentation transcript:

1 Strain-Based Resistance of Single-Walled Carbon Nanotubes Abstract The goal of this project is to fabricate devices to test the strain-based change in resistance of Single-Walled Carbon Nanotubes (SWCNT) for use in micro-scale, high resolution magnetometry. To do this, we must first fabricate a device with electrically contacted SWCNTs, then release the device onto a flexible substrate for strain testing. We report progress in growth techniques, testing techniques, and comparisons between Chemical Vapor Deposition (CVD) grown tubes and commercially available SWCNTs. Jonathon A. Brame 1, Johnathan Goodsell 1, Dr. Stephanie A. Getty 2 1 2006 ESMD Faculty/Student Research Team Participant, Department of Physics, Provo, UT, jon.brame@gmail.com 2 NASA Goddard Space Flight Center, Materials Engineering Branch, Code 541, Greenbelt, MD, Stephanie.A.Getty@nasa.gov Fabrication After depositing a thin film layer of Iron, SWCNTs were grown on the SiO 2 substrate through a CVD process using methane and ethylene as the feed gases. Next we used a shadow-masked gold evaporation to establish electrical contact with the nanotubes and coated the whole device with Parylene. Once the SiO 2 is etched away from behind, we are left with an electrically contacted SWCNT device on a flexible substrate. (see Figure 3) SiO 2 Fe Thin FilmSWCNTs Parylene Gold Contacts Etching (KOH) Fig 4 Fig 3 Once the SWCNTs were released onto the flexible substrate, the device was mounted onto a frame made of ceramic chips with gold contact pads around the outside. The contact pads on the frame were then wire-bonded to the gold contacts on the nanotubes (see Figure 4). Once the sample was attached and contacted to the frame, the whole device was mounted onto a probe station for resistance testing (see Figure 5). Top view Background The remarkable effect of strain on the conductivity of SWCNTs has been demonstrated through local deformation (see Figure 1), and through stretching of the tube structure (see Figure 2). We seek to extend those results to an array of SWCNTs in a strain sensor. Fig. 1 Conductivity versus strain in a SWCNT depressed by an AFM tip (Tombler et al. Nature, 2000). Fig 2 Drastic change in conductivity due to stretching was measured for a semi-conducting SWCNT (Cao et al. Physical Review Letters, 2003). Stretching Results The initial results of the stretch-testing show evidence of reversible, strain-based change in resistance in SWCNT devices. Figure 10 shows both the characteristic resistance changes with stretching/releasing, as well as several distinct resistance “levels” possibly activated by individual nanotube contacts changing in the stretching process. - Stretch - Release slack in device Fig 10 A step pattern was used for testing resistance while stretching, stretching twice by 4 µm, then releasing back 4 µm Fig 8 The SEM image on the left shows SWCNTs grown with Iron Nitrate catalyst, while the image on the right shows SWCNTs grown using the thin film iron catalyst technique (Note that the image on the right is at twice the magnification as the image on the left). Level 2~450 kΩ Level 1~300 kΩ Growth Results Using thin film iron catalyst has shown marked improvement over the initial iron nitrate catalyzed CVD growths (see Figure 8), yielding initial SWCNT resistance decrease of several orders of magnitude. Additionally, magnetic tests were performed on tubes grown using this new method to ensure that there is no inherent magnetic effect from the iron catalyst (Figure 9). Table 1 Due to the vastly different stretching characteristics of parylene and SWCNTs, uniform stress is not distributed evenly throughout the sample during a stretching. Most of the strain is absorbed in the parylene, while the nanotubes may slip within the substrate rather than stretch as desired. As the parylene stretches, however, it should cause enough displacement of the tubes to change the resistance, since nanotubes resistance are subject to change through bending as well as stretching (see Tombler et al.) Table 1 Applications A device of this scale capable of measuring strain would be very useful in the nano-technology industry. Specifically this nano-sensor is being developed to create a micro-scale vector magnetometer for use in magnetospheric science and planetary magnetic study and mapping (see Figures 6 & 7). Fig 6 Earth’s magnetosphere Fig7 Possible planetary magnetic exploration Conclusions and Future Work Increased Growth Density of SWCNT Transfer of CVD grown SWCNTs onto flexible substrate Fabrication of device to measure stretch-based resistance changes Development of methodology for stretching SWCNTs Preliminary results from stretch-testing Preliminary comparisons of CVD and commercial SWCNTs Future Work Joint-effort testing between NASA and BYU Continuation of stretch-testing Further testing of commercially available tubes Fabrication of micro-magnetometer Fig 5 Acknowledgements ESMD Program, Rocky Mountain Space Grant Consortium BYU- Dr. David Allred, Johnathan Goodsell Fisk University- Melissa Harrison C. Taylor, D. Dove, C. Hoffman, L. Wang Figure 9 The resistance of the nanotube device remained constant through a changing magnetic field


Download ppt "Strain-Based Resistance of Single-Walled Carbon Nanotubes Abstract The goal of this project is to fabricate devices to test the strain-based change in."

Similar presentations


Ads by Google