Presentation is loading. Please wait.

Presentation is loading. Please wait.

P09451 Mid-Project Review Bryan McCormick (ME) Project Manager Andy Freedman (ME) Heat Transfer/Fluids Analysis & Design John Kreuder (ME) Thermal Modeler.

Similar presentations


Presentation on theme: "P09451 Mid-Project Review Bryan McCormick (ME) Project Manager Andy Freedman (ME) Heat Transfer/Fluids Analysis & Design John Kreuder (ME) Thermal Modeler."— Presentation transcript:

1 P09451 Mid-Project Review Bryan McCormick (ME) Project Manager Andy Freedman (ME) Heat Transfer/Fluids Analysis & Design John Kreuder (ME) Thermal Modeler Ken McLoud (ME) Structural Designer Jon Holdsworth (EE) Electrical System Designer Gabriela Santa Cruz (IE) Engineering Economics Sponsored by:

2 Current System

3

4 Project Description Improved test stand for studying thermo-electric modules High Level Customer Needs: –Implement air-cooling on cold side of thermo-electric array in addition to the water-cooling system. –Be able to experimentally validate thermoelectric system models and enable more parameters to be explored. –Improve user interface and data acquisition to allow greater ease of use of the test stand. –Improve set-up and shut-down procedures to reduce assembly times

5 System Architecture

6 Piping

7 Valves for Air/H2O Interchange

8 Power Unit Improved Tool Clearance Force Sensors

9 Power Unit 4 zones Interchangeable Fins

10 Power Unit

11 Permanently Mounted Thermocouples

12 Current Status Design meets all needs except –CN12: Quantify temperature distribution across module reliably Design meets all specifications except –A iii.: Measure thermal gradients across hot and cold module surfaces –C ii.: Over-temperature shutdown for heater –D ii.: Reduce module failures during exchange and assembly

13 Current Status On target to meet $7500 budget –Current budget ~$5700 Schedule: –Design completed on schedule –Minor design revisions to be completed within next week –On track to meet parts in house date

14 Identified Risks & Items from Design Review Safety shutdown for heater –Investigating flow sensor for heater Thermocouple placement to accommodate all possible setups –Adjust length of grooves to accommodate all setups, thermocouples will be under module but not centered Control System functionality –Current design appears feasible, testing will be completed once parts arrive Thermal Expansion –Testing will be performed with force sensors to determine room temperature pressures that equate to steady state pressures Module failures –Force measurements, uniform pressure –Investigate new wire connectors Costs of aluminum piping –Switch to PVC for cold pipe, steel for hot pipe Manufacturing time –Many parts will be in before parts in house date –Build schedule set to complete by end of week 5

15 MSD II Milestones 3/9/09 Test Plan Finalized 3/19/09 All Parts in House 4/10/09 Assembly Complete 5/1/09 Testing Complete 5/8/09 Documentation Finalized 5/15/09 Final Project Review