1 Launching MIURA sample prep system
The next generation of automation DSP SYSTEMS Information : or Internet:

2 Introduction The Full-Automatic Sample Preparation System for dioxins and PCBs analysis has three features… High Performance Clean-up User-friendly Column Design Unique way of flow switching Main advantages Low solvent consumption Hexane 90 ml Toluene 4 ml Run-time 90 minutes No cross contamination Columns easy to connect and no leakage Competitive prices

3

4 Availability and Service
The system is in Europe and several other countries available via DSP Systems as : GO-2HT capable of running two samples parallel GO-4HT capable of running four samples parallel GO-6HT capable of running six samples parallel Installation, service and maintenance will be supplied by DSP Systems A full maintenance contract is optional with a response time of 24 hours for customers within a radius of 300 km from the middle of the Netherlands and 48 hours within the rest of the EU countries

5 General Dioxin method Sample Sample extraction or dilution Clean-up
16/04/2017 General Dioxin method Sample spike with 13C labelled standards Sample extraction or dilution concentration Clean-up add Control standard add Recovery standards concentration GC-HRMS or GC-MS/MS Required time 1-2 days

6 Background --- Features of New System
High performance clean-up User-friendly column design Unique way of flow switching without valves

7 Background --- Features of New System
High performance clean-up 4 columns Silver nitrate Si column Sulfuric acid Si column Carbon column Alumina column Heated Purification and elution Enhances dioxins elution speed Accelerate a chemical reaction User-friendly column design … Unique way of flow switching without valves

8 Background --- Features of New System
High performance clean-up User-friendly column design Easy applying sample Easy connection Disposable parts No cross contamination No washing is required Clap! Clap! Clap!

9 Background --- Features of New System
High performance clean-up 90 mL of hexane for eluting dioxins and PCBs: Trapping dioxins and NO-PCBs on carbon Trapping MO and NDL-PCBs on alumina Open the pinch valve Elution PCBs with 1.5 ml of toluene Close the pinch valve and open the other pinch valve Elution Dioxins with 1 ml of toluene

10 First results Recovery in real samples Sample type: PFAD Fish oil
Mix of fatty acid Minerals Compound feed

11 First results PeCDD trace peak of interest is 1,2,3,7,8 *1
sample tocopherol Result after classical clean-up Result after clean-up using the new system *1 TEF = 1,0

12 First results HxCDF trace peak of interest is 1,2,3,5,7,8; sample tocopherol
Result after classical clean-up Result after clean-up using the new system

13 60mL 100mL 1.5hrs 1.5hrs 1 hr GC-MSMS GC-HRMS Conclusion Extraction
Purification Measurement GC-MSMS 1.5hrs 1.5hrs 1 hr GC-HRMS 60mL 100mL Multiple sample extraction Full Automatic Sample preparation System GC-MSMS or/and GC-HRMS High sample Throughput Eco-friendly analysis Results available within 8 hours

14 DSP SYSTEMS Information : info@dspsystems.eu or +31 6-1366 4946