D AA R Michael P. Doble, P.E., 414-935-4435, PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL.

Similar presentations


Presentation on theme: "D AA R Michael P. Doble, P.E., 414-935-4435, PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL."— Presentation transcript:

1 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. ADVANCED METHODS FOR SURVEYING BURIED UTILTIES INTRODUCTION TO SPAR AND CASE STUDY THE INFORMATION CONTAINED HEREIN IS PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. LEADERSHIPLEADERSHIP EXPERIENCEEXPERIENCE QUALITYQUALITY D AA R KNOWLEDGEKNOWLEDGE

2 Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Summary Problem/Solution The Spar 300 System Why a 3d Survey? 3d Survey Concepts Sample Projects –High Pressure Gas Main Relocate –DOT Highway Project –Cable Crossing in River

3 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. The Problem Poorly mapped and abundant existing underground facilities complicate design and excavation Current Workflow –One-call service: Facilities marked –Facilities are un-earthed for depth –Spot location depths documented Problems –2d data inaccuracies due to distortion –Spot depths may or may not tell the whole story –Depths are documented; not elevations Results –Designs require utility relocation –Utility strikes are common and dangerous – April 2 nd, 2008

4 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. The Problem

5 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. The Solution Prepare a 3d survey! The Spar System –3d Magnetic Sensor –Trimble Access: Utility Survey Software FieldSens TM Technology –Trimble RTK-GNSS receiver –Transmitter

6 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Why is Surveying Better than Locating? We are professional surveyors: we provide professional quality data Avoid strikes and improve safety with accurate surveying Provide for improved design workflow: data up front Measure and document locating subsystem RMS error Reduce depth ambiguity by surveying elevations (x, y AND z) Locate with survey grade precision: RTK-GNSS Combine overall errors from geospatial and locate subsystems –Reduce the total effort to locate, map, document This technology allows for surveying from offset positions –Map the line without constant need to stay on peak or CL –Move away from distortion –Termed as casual contact –Survey where traditional methods don’t allow

7 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Underwater or Deep Utility Mapping Wireless sensor networking, synchronization results in improved measurement geometry

8 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Peak Null Single-Spar Line Mode Target cable “Bleedover” cable Model

9 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Spar Range Summary Single Spar Line –Single epoch measurement, <3 meter range Dual Spar Line –Single epoch measurement, <15 meter range Dual Spar Sonde Tracking –Single epoch measurement, <8-12 meter range

10 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Representative Projects High Pressure Gas Main Relocate –Objective: Save cost on hydroexcavation –Objective: Verify a difficult locate DOT Highway Project: –Objective: Save time and avoid utility strikes Cable Crossing in River –Objective: Document cable location for dredging

11 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. High Pressure Gas Relocate

12 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Hydroexcavation to Verify

13 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Depth Verification

14 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Wisconsin Hwy 33 Saukville

15 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Cable Crossing in River

16 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Dual-Spar Water Locate Set-up

17 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Project Results High Pressure Gas Main: Gas utility crews saved three days of excavation time in verification of pipe location and elevation Highway Project: Grading crews were able to grade over the line without any inadvertent strikes River Crossing: Dredging crew was able to dredge with confidence allowing the work to be completed in this section two days ahead of schedule

18 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. DAAR Experience in Summary Spar performed as specified Gas main and tap elevations consistently measured from surface to 12 feet below ground with accuracy of +/- 3 to 5 inches Highway 33 project compared previously measured gas main GPS elevation points to Spar data and noted +/- 1.5 inch elevation differences – very good! DEEP depths provide a challenge Liability concerns alleviated by documented accuracy

19 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. QUESTIONS INTRODUCTION TO SPAR AND CASE STUDY THE INFORMATION CONTAINED HEREIN IS PROPRIETARY AND CONFIDENTIAL. © 2012 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. D AA R ADVANCED METHODS FOR SURVEYING BURIED UTILTIES

20 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. System Architecture

21 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Note Records in Trimble Access

22 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. Export of Data

23 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. CSV File: Translated

24 D AA R Michael P. Doble, P.E., mike.doble@daarcorp.com, 414-935-4435, www.daarcorp.com PROPRIETARY AND CONFIDENTIAL. © 2013 DAAR ENGINEERING, INC. ALL RIGHTS RESERVED. EMF Equipment