SEMS Introduction By Overseas Sales Division 2014 May 31 th.

Similar presentations


Presentation on theme: "SEMS Introduction By Overseas Sales Division 2014 May 31 th."— Presentation transcript:

1 SEMS Introduction By Overseas Sales Division 2014 May 31 th

2 Part I SEMS System Introduction  What is SEMS  Application  Functions  System Sketch  Benefits of SEMS Part II Product  Data Concentrator  Terminal Controller  SEMS Monitoring Software  Function Expansion Modules Part III Project Reference Content

3  SEMS is short for Smart Energy Management System  The system use PLC or Zigbee technologies to remotely manage and control the outputs of individual lighting points, and GPRS technology between system Server and Data Concentrators (i.e. a main controller to manage all data and orders between individual lighting points and system Server.).  Each light can be dimmed using automatic profiles to match the specific requirements of the surrounding area throughout the night. At the users command, such as in the event of an emergency, lights can be brought back up to full brightness at the touch of a button, from either a computer, laptop, or smartphone.  Every lighting point within the inventory is remotely monitored, with any faults being reported to the specified user(s) via scheduled email or mobile phone message. Reports in excel or graph formats, detailing the energy usage of each light, or a particular group of lights, are also available.  So far, SEMS has been successfully installed by over 300,000 units across the world and is used to realise significant cost savings and reductions in carbon emissions. Part I SEMS System Introduction 1. What is SEMS

4  Road Light Smart Control  Tunnel Light Dimming System  Solar Light Smart Control  Industrial Light Smart Control  Landscape Illumination Smart Control Part I SEMS System Introduction 2. Application

5  Remote control individual lamp via computer or smartphone.  Dimming lamps during night.  Timing control, Longitude & latitude control.  Lamp operation status detection & failure alarm.  Remote & local software upgrade  Failure notice & map locating function.  Electricity data collection, consumption reports, data export functions. Part I SEMS System Introduction 3. Functions

6 4. System Sketch The system is composed of 3 parts: SEMS monitoring software Data Concentrator(s) Terminal Controller(s) Part I SEMS System Introduction

7 4. Benefits of SEMS

8 Energy Conservation Adjusting lamps illumination to a configured level at midnight; 30% extra energy saving by dimming function; Configure illumination levels according to requirements of roads, time, date; Lengthen lamp lifetime SEMS Dimming Function For example : 18:00——19:00 50% Brightnes 19:00——22:00 100% Brightness; 22:00——06:00 50% Brightness Time6pm7pm8pm9pm10pm11pm12pm1am2am3am4am5am Brightness 50%100% 50% Total Power Consumption 800% Hour12 Power Consumption 67% Energy Saving 33%

9 Five Function Easy remote management, control, test, signal communication, dimming, and inspection; Cellphone control (GSM mode, use together with GSM modem.) System Requirements for Cellphone Control Android recommended (IOS pending) 2G sim card recommended GSM modem required

10 Safety Protection Detect lamp failure/ theft, report alarm, lengthen lamp lifetime 30%. Report over-load circuit and alarm; Alarm notice: Server, cellphone message, email.

11 Wisdom Management Data collection and create report, analyze data efficiently Configure illumination levels according to requirements of roads, time, date; Lengthen lamp lifetime

12 Quick Maintenance Detect failure and alarm, no labor cost for touring roads, save maintenance cost 50%. Configure illumination levels according to requirements of roads, time, date; Lengthen lamp lifetime

13 Part I SEMS System Introduction  What is SEMS  Application  Functions  System Sketch  Benefits of SEMS Part II Product  Data Concentrator  Terminal Controller  SEMS Monitoring Software  Function Expansion Modules Part III Project Reference Content

14 Data Concentrator plays a key role in structure and adjustment of the communication network for SEMS system. It receives data from Terminal Controller(s), forward commands to them; and it communicates with Server, receives commands and reports all related data. Part II Product 1. Data Concentrator

15 Item No. CC08 SeriesCC09 Series CC08CC08TCC08ZCC09 Application Road Lighting, Landscape Illumination, Industrial Lighting Tunnel Light Zigbee Control Lighting Road Lighting, Landscape Illumination, Industrial Lighting Model & Application 1. Data Concentrator

16 CC08 Functions & Features 1. Data Concentrator  Data collection: Collect data including voltage, current, power, etc. from Terminal Controller(s), support MODBUS protocol.  Communication: Ethernet, GPRS, Zigbee.  Adjust lighting schemes automatically, according to longitude & latitude.  Power on/off /dim/query the controllers and have signal relay function.  Support magnetic door switch detection.  Failure alarm notice function, via MSG, email, Server.  Support software update locally or remotely.

17 Part II Product 2. Terminal Controller Terminal controllers receive commands from a concentrator to power on/off or dim the lamp. Terminal controllers can monitor the status of the lamp and transmit the data back to the concentrator.

18  Remote power on/off the lamp.  0-10V dimming interface  Autonomous running function  Remote current, voltage, power reading function.  Sodium and LED lamp failure detection function.  Failure report  Lightning protection RTU09B Functions & Features 2. Terminal Controller

19 Part II Product 3. SES Monitoring Software The software runs on host computer, it serves as a platform to control / manage the system, to collect measured data (current, power consumption, alarm, etc.) and monitor the status of the lighting system.

20 3. SEMS Monitoring Software Homepage Introduction A BC D EFG H I J K L M N

21  A. Application function menu button  B. User account management and user log and hardware log management  C. Directory configuration/ concentrator configuration/ terminal task setting  D. Device deployment on map and device status map query  E. Hardware management  F. Output consumption report  G. Provide help information  H. Current main function menu  I. Current area information  J. Devices directory details under the current area  K. Turn on the chosen devices  L. Turn off the chosen devices  M. Alarm reminding and alarm numbers display  N. Work space of the current area 3. SEMS Monitoring Software Homepage Introduction

22 3. SEMS Monitoring Software Basic Task Introduction 1.Lamp on / off 2.Lamp Dimming 3.Lamp Failure Alarm & Notice 4.Power Data Report 5.Asset Report

23 Anti-Theft Devices Cable Anti-Theft Module Cable Anti-Theft Terminal Use Light Sensor to Drive Lamp On/Off Photocell Module (One/two pieces for each project) Collect Current Data from other Ammeter Current Expansion Module (Built-in power distribution cabinet) 4. Function Expansion Modules (Optional Devices)

24 Part I SEMS System Introduction  What is SEMS  Application  Functions  System Sketch  Benefits of SEMS Part II Product  Data Concentrator  Terminal Controller  SEMS Monitoring Software  Function Expansion Modules Part III Project Reference Content

25 Part III Project Reference  City Road Lighting Smart Control  New Energy Street Light Smart Control  Tunnel Lighting Smart Dimming System  Industrial Lighting Smart Control  Landscape Illumination Smart Control Project Scenarios

26 City Road Lighting Smart Control Stuttgart, Germany 200pcs LED lamps April 2011 Unilumin provided

27 City Road Lighting Smart Control Istanbul, Turkey 2000pcs LED lamps May 2013 Client provided

28 City Road Lighting Smart Control Tehran, Iran 200pcs LED lamps May 2014 Client provided

29 City Road Lighting Smart Control Israel 36pcs LED lamps Mach 2014 Client provided

30 City Road Lighting Smart Control Guangzhou-Shenzhen Highway, China 7000pcs LED lamps April 2010 Unilumin provided

31 City Road Lighting Smart Control Xiamen, China 2000pcs HPS lamps Sep. 2011 Client provided

32 City Road Lighting Smart Control Shenyang, China 15000pcs LED lamps Jun 2012 Client provided

33 Tunnel Lighting Smart Dimming System Gansu, China 1578pcs LED Tunnel lamps Mar, 2012 Client provided

34 Landscape Illumination Smart Control Jiangxi, China 395pcs Distribution Box Sep, 2013 Client provided

35 SERVICE HOTLINE : 4008-090-880 Website : www.iotcomm.com www.iotcomm.com SHENZHEN IOTCOMM TECHNOLOGY CO., LTD (Overseas Sales) Add.: 1002#, Chinese Overseas Scholars Venture Building, Hi-tech Area, Nanshan District, Shenzhen, China. Tel : 0755-86329565 Fax : 0755-86329569 XIAMEN IOTCOMM TECHNOLOGY CO., LTD (HQ & Production) Add.: 3F, North Building, N0.1 Cengcuoan North Road, Software Park, Hi-tech Area, Siming District, Xiamen, Fujian State, China. Tel : 0592-2517558 Fax : 0592-2520926