Presentation is loading. Please wait.

Presentation is loading. Please wait.

C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur

Similar presentations


Presentation on theme: "C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur"— Presentation transcript:

1 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
We are NABL Accreditation at Lab and Site for : Energy & Power CT/PT, Open Access Connection Metering Unit Dead Weight Tester Transformer, CT/PT, Energy Meter, Conductor Testing NABL Accreditation at Lab and Site for Mechanical, Thermal and Electro-technical Training and Consultancy Research and Development Centre A Primary Standard NABL Accredited Laboratory C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

2 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Calibration Laboratory (NABL C-0768; lab and site ) : - Energy and Power FIRST IN INDIA FIRST IN INDIA NABL accredited laboratory to calibrate the reference meter of 0.02 Class at Site. Equipped with COM 3003 Zera Germany, master with direct traceability to NPL India and DKD Germany. Calibration meeting the requirements of Electricity Regulatory Board. C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

3 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Laboratory (NABL C-0768; lab and site ) : - Energy and Power Electricity Regulatory Board Facility for calibration of ABT meter, Energy Meter, LT/HT Accuchek, Energy meter calibrator, Power meter /Analyzer, CT/PT Burden Box, Meter Test Bench/ Source, Reference Standard. CT / PT Calibration Facility for calibration of Standard CT / PT , AC High Voltage and CT / PT Test set . C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

4 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
Energy , Power & CT ,PT Calibration Electricity Regulatory Board Parameter Capability Power / Energy 1Ø/ 3 Ø ;  40V to 320V, 40 Hz to 70 Hz, 1mA to 120 A 0.01% of rdg Power Factor   PF Frequency 40Hz to 70 Hz  0.025% CT up to 2000A Ratio Error Phase Error 0.03% 2.5 minute PT up to 33 kV Ratio Error 0.08% 4.0 minutes C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

5 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Laboratory (NABL C-0769; lab and site ) : - Pressure Primary Standard for DWT Primary Standard for Dead Weight Tester Calibration upto 1200 kg/cm2 using Cross Float Method. Equipped with DH-Budenberg UK Dead Weight Tester of Class 0.007% rdg Traceable to UKAS, UK. Facility for calibration of DWT, Pressure Calibrator, Master Pressure Gauge, Pressure Transmitter, Transducer, Digital Pressure Indicator etc. C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

6 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
(B) C and I Calibrations Pvt. Ltd., Jaipur Testing Testing Activity Distribution Transformer CT/PT Energy Meter AAC/AAAC/ACSR Conductor C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

7 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
12+ Years of Accreditation (B) NABL Accredited Calibration Laboratory C&I Systems Kota- 15 years old Calibration Laboratory NABL accredited since 2000. Currently NABL accredited for Mechanical, Thermal and Electro-technical calibration. NABL accredited for site calibration as well. C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

8 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Calibration Laboratory C&I Systems Kota- Electro-technical (NABL C-0190) Mechanical (NABL C-0088) Pressure & Vacuum Dimension , Angle Mass & Balance Volume & Density Speed Sound Force Temperature & Humidity (NABL C-0191) 12+ Years of Accreditation C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

9 NABL Accredited Calibration Laboratory C&I Systems Kota-
Our Specialities Calibration of : High Voltage AC up to 100 kV & DC up to 35 kV Hygrometers (Humidity ) Volume Hydrometer (Density) Medical Instruments like BP Instrument , Centrifuge, Incubator, Glass wares, Burette , Pipette etc. 12+ Years of Accreditation C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

10 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Calibration Laboratory (Mechanical) C&I Systems Kota- Our Coverage And Capabilities Discipline Parameter Capability Pressure Pressure Calibrator, Gauges, Transducer, Tx, Kg/Cm2 0.04% FS Vacuum Vacuum Calibrator, Gauges, Transducer 0.045% FS Spirit Level Up To 300mm 16 µm/m Dimension Vernier, I/S, O/S Micrometer, Dial Gauge, Height Gauge, Borge Gauge, Feeler Gauge, Bore Gauge, Feeler Gauge, Measuring Tape/ Scale mm Mass & Balance Weights 1mg To 20kg Balance Up To 100kg 0.008 mg to 0.73g mg to 2.689g C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

11 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Calibration Laboratory (Mechanical) C&I Systems Kota- Our Coverage And Capabilities Discipline Parameter Capability Volume 10 µl To 5 ltr. 0.02 µl – ml Speed (RPM) Tachometer (upto RPM) 0.02% FS Sound Sound Level Meter 94db, 114db 0.53 dB Density Hydrometer 0.6 to 2 g/ml g/ml Angle Bevel Protector/Combination Set / Clinometer 3. 6 min. Force Tension 0.1kN - 50kN, Compression 40kN kN 0.5% 0.7% C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

12 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Calibration Laboratory (Electro-technical) C&I Systems Kota- ( Our Coverage And Capabilities Discipline Parameter Capability Electro- technical   Power / Energy 63 V To 415 V,10 mA to 500 A   0.065 % to 0.5 %   Power Factor    PF   Frequency Up To 10 Mhz   0.004%   Current(AC/DC) 10 µA to 1000A    Voltage(AC/DC) Up to 1000 V   0.03%-0.9%   0.005% - 0.5%   Resistance 0.001Ω T0 400 MΩ   Insulation Resistance Up To 2GΩ    0.013%-0.93%   2.4%   Inductance 10 µH To 10H    0.35% %   Capacitance 10nF To 10mF   0.13% % C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

13 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Calibration Laboratory (Electro-technical) C&I Systems Kota- Our Coverage And Capabilities Discipline Parameter Capability Electro- technical   High Voltage AC 100kV   High Voltage DC 35kV    0.7% to 2.8%    2.9%   Oscilloscope Time Mark 2ns To 5 S   Band Width 600 MHz 5mv To 120V    0.014%-0.13%    3.46% 0.3%   Time (Stop Watch)    0.37 Sec-0.7 Sec.   Turn Ratio Up To 2000 Turn    0.12%-1.5%   Temp. Simulator/Indicator    0.02o C-0.26%o C C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

14 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Calibration Laboratory (Thermal) C&I Systems Kota- Our Coverage And Capabilities Discipline Parameter Capability Temperature RTD. T/C, Thermometer, Bath , Oven, Furnace - 350C to 12000C 0.10C C Humidity 20% to 90% RH 2.06% C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

15 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
(D) Training and Consultancy Technical Training on Calibration - Training By Experts Module Type of Training Power and Energy Principles & Techniques in Power & Energy Calibration and Uncertainty of Measurement CT / PT Principles & Techniques in CT/PT Calibration and Uncertainty of Measurement Electrical Calibration Voltage, Current, Resistance, Watt Meter, Oscilloscope, Digital Multimeter and Uncertainty of Measurement Mechanical Calibration Dimension, Mass & Volume, Pressure & Vacuum, Force, Speed, Sound etc. and Uncertainty of Measurement Thermal Calibration Temperature & Humidity Calibration and Uncertainty of Measurement C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

16 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
Training and Consultancy Consultancy - Consultancy for Value addition Standard Certification / Accreditation ISO/IEC 17025 Testing and Calibration Laboratories ISO 15189 Medical Laboratories NABH, QCI Hospitals and Health Care units ISO 9000, ISO14000, TS16949 Industries / Public Sectors / Govt. Institutions ISO 22000 Food Industries / Food Outlets C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

17 C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur
(E) Research and Development Sectors Covered - Our Patent And Other Research Area Type of R&D Our Patent Patent File No 1271/DEL/2012 for “ A PROCESS for treating dye house waste water for reclamation & reuse” Waste Tyre Waste Tyre Pyrolysis for recovery of value added products Solar Energy Solar Applications for Energy Conservation Water Purification Water purification using Magnetic De-scaling Effluent Water Treatment Recovery & reuse of Effluent Water for zero Water Discharge C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical

18 Thank you Contact us at ashokpatnijain@gmail.com
C&I Thank you Contact us at Visit us at C&I Systems, Kota NABL Accredited Calibration Laboratory for Mechanical, Electro-technical and Thermal C and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard Calibration Laboratory for Mechanical & Electro-technical


Download ppt "C&I Systems, Kota C and I Calibrations Pvt. Ltd., Jaipur"

Similar presentations