Presentation is loading. Please wait.

Presentation is loading. Please wait.

Luciano Musa - CERN 1 500cm 83cm 248cm TPC DETECTOR 88us 1MIP = 4.8 fC = 3 x10 4 e Dynamic : 30 MIP S / N = 30:1 1MIP = 4.8 fC = 3 x10 4 e Dynamic : 30.

Similar presentations


Presentation on theme: "Luciano Musa - CERN 1 500cm 83cm 248cm TPC DETECTOR 88us 1MIP = 4.8 fC = 3 x10 4 e Dynamic : 30 MIP S / N = 30:1 1MIP = 4.8 fC = 3 x10 4 e Dynamic : 30."— Presentation transcript:

1 Luciano Musa - CERN 1 500cm 83cm 248cm TPC DETECTOR 88us 1MIP = 4.8 fC = 3 x10 4 e Dynamic : 30 MIP S / N = 30:1 1MIP = 4.8 fC = 3 x10 4 e Dynamic : 30 MIP S / N = 30:1 LATERAL VIEW OF THE TPC 18 trapezoidal sectors Inner chamber 5504 pads Outer chamber SEGMENTATION OF THE READOUT PLANE

2 Luciano Musa - CERN 2 TPC FEE: MOUNTING 36 trapezoidal sectors Inner chamber Outer chamber FEC C1 : 18 FECs C6 : 20 FECs C4 : 20 FECs C3 : 18 FECs C2 : 25 FECs FRONT VIEW C5 : 20 FECs SIDE VIEW 128 channels Front End Card (FEC) Capton Cable 140mm 190mm

3 Luciano Musa - CERN 3 Each TPC Sector is served by 6 Readout Subsystems Overall TPC: 4356 Front End Card 216 Readout Control Unit GLOBAL ARCHITECTURE FEE ARCHITECTURE FEC 128 ch FEC 128 ch FEC 128 ch FEC 128 ch CONF. & R/O MON. & CTRL BOARD CONTROLLER DATA PROC. DATA MEMORY DAQ INT (DDL-SIU) DCS INT (PROFIB, ETHER,...) TRIGGER INT (TTC-RX) CONFIG. & READOUT NETWORK (100 MB / s) DCS NETWORK RCU CRXUX LOW VOLTAGE POWER SUPPLY FEC COOLING

4 Luciano Musa - CERN 4 Kapton cables to TPC FRONT-END CARD 128-CHANNEL FRONT-END CARD cooling pipe readout bus connectors control bus connector power supply connector voltage regulators current monitoring & supervision ALTROs Shaping Amplifiers GTL transceivers (back side) FEC COOLING LV SUPPLY

5 Luciano Musa - CERN 5 FRONT_END CARD FEE PARAMETERS TO BE MONITORED AND/OR CONTROLLED (PRELIMINARY !)   Front End Card (FEC) Temperature:1 value (10 bits) / FECR Volt. Reg. State (on/off):8 values (8 bits) / FEC R/W Power Switches (on/off):2 values (2 bits) / FECR/W Analogue Voltage:1 value (10 bits) / FECR Digital Voltage:1 value (10 bits) / FECR Status / Error Register:1 value (64 bits) / FECR/W   Readout Control Unit (RCU Volt. Reg. State (on/off):4 values (8 bits) / FEC R/W Power Switches (on/off):1 values (2 bits) / FECR/W Digital Voltages:2 value (20 bits) / FECR Status / Error Register:1 value (64 bits) / FECR/W   Events that could damage the FEE components are hardware protected.   The FEE cooling and LV POWER SUPPLY have their independent set of sensors.


Download ppt "Luciano Musa - CERN 1 500cm 83cm 248cm TPC DETECTOR 88us 1MIP = 4.8 fC = 3 x10 4 e Dynamic : 30 MIP S / N = 30:1 1MIP = 4.8 fC = 3 x10 4 e Dynamic : 30."

Similar presentations


Ads by Google