1 Engineering/commissioning
To start, a couple of words as to how Drive ES SIMATIC is integrated into the product environment. Drive ES Basic Drive ES PCS7 CFC V 5.1 (Prerequisite for Drive ES Graphic) Drive ES Graphic Drive ES SIMATIC Communications Engineering/commissioning Product position: Drive ES SIMATIC is a function block library which supports you when establishing communications between the CPU and drives. The function blocks run on a SIMATIC-CPU.

2 Drive ES SIMATIC: The Drive ES SIMATIC blocks are configured on a PC and then downloaded into the CPU. SIMATIC S7

3 SIMATIC S7 Drive ES SIMATIC: Blocks are provided for communication functions. These blocks do not have to be developed or programmed - they only have to be parameterized. The following blocks are available:

4 Non-cyclic parameter transfer
SIMATIC S7 Blocks: Cyclic data transfer Non-cyclic parameter transfer Reading-out fault texts from drives (e.g. for OP display) Project examples Generator to easily expand the communications Download from the CPU (when replacing drives) Converter from parameter set > DB (when replacing drive units) Converter for projects from older blocks into Drive ES SIMATIC format. Tested blocks are available in five languages Blocks are multi-instance capable Blocks can also be configured with CFC

5 Using project examples:
This is how you can use project examples to quickly establish communications between the CPU and your drives. 2. Project example Copy 1. Own project NEW SIMATIC S7 Download into the CPU

6 Expanding project examples:
You can simply expand the project example using the data block generator. 2. Project example 3. Expand hardware 4. Start DB generator Copy 1. Own project NEW SIMATIC S7 Download into CPU 5. Expand STEP7 program

7 Replacing drives: Here, you can see how the parameter set of the drive is downloaded from the CPU after a drive has been replaced. 2. Set the PROFIBUS address at the new drive unit 4. The download FB transfers all of the parameters from the download DB(s) F 1 3 5 7 9 2 4 6 8 K . + / - * A Z D E L I N S C G B H M O J P Q U W R T V X Y : = ( \ , ) F13 SIEMENS 6SE7016-1EA30 WR 2,2 kW Ooliver SIMOVERT SC replace device SIMATIC S7 SIEMENS 6SE7016-1EA30 WR 2,2 kW Ooliver SIMOVERT SC 3. Download parameters after the drive has been replaced, e.g. activated via OP 1. Replace the defective drive unit STEP7 program – download DBs into the load memory

8 Save the STEP7 program with generated DB in the SIMATIC CPU
Replacing drives: Here, you can see how a parameter set in a data block is converted for “download from the CPU“. F 1 3 5 7 9 2 4 6 8 K . + / - * A Z D E L I N S C G B H M O J P Q U W R T V X Y : = ( \ , ) F13 SIMATIC S7 After start-up has been completed, upread the parameters from the drive Save the STEP7 program with generated DB in the SIMATIC CPU